This message describes the event of an order being created, modified, accessed, or deleted. This message may only include information about a single patient.
Note
An order record typically is managed by a non-DICOM system. However, DICOM applications often manipulate order records, and thus may be obligated by site security policies to record such events in the audit logs.
Table A.5.3.13-1. Audit Message for Order Record
|
Real World Entities
|
Field Name
|
Opt.
|
Value Constraints
|
|
Event
|
EventID
|
M
|
EV (110109, DCM, "Order Record")
|
|
EventActionCode
|
M
|
Enumerated value:
C = create
R = read
U = update
D = delete
|
|
EventDateTime
|
M
|
not specialized
|
|
EventOutcomeIndicator
|
M
|
not specialized
|
|
EventTypeCode
|
U
|
not specialized
|
|
User (1..2)
|
UserID
|
M
|
The identity of the person or process manipulating the data. If both the person and the process are known, both shall be included.
|
|
AlternativeUserID
|
U
|
not specialized
|
|
UserName
|
U
|
not specialized
|
|
UserIsRequestor
|
U
|
not specialized
|
|
RoleIDCode
|
U
|
not specialized
|
|
NetworkAccessPointTypeCode
|
U
|
not specialized
|
|
NetworkAccessPointID
|
U
|
not specialized
|
|
Patient (1)
|
ParticipantObjectTypeCode
|
M
|
Shall be: 1 = Person
|
|
ParticipantObjectTypeCodeRole
|
M
|
Shall be: 1 = Patient
|
|
ParticipantObjectDataLifeCycle
|
U
|
not specialized
|
|
ParticipantObjectIDTypeCode
|
M
|
Shall be: 2 = Patient Number
|
|
ParticipantObjectSensitivity
|
U
|
not specialized
|
|
ParticipantObjectID
|
M
|
The patient ID
|
|
ParticipantObjectName
|
M
|
The patient name
|
|
ParticipantObjectDetail
|
U
|
not specialized
|
|
ParticipantObjectDescription
|
U
|
not further specialized
|