| DICOM PS3.8 2024e - Network Communication Support for Message Exchange |
|---|
The following standards contain provisions which, through reference in this text, constitute provisions of this Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this Standard are encouraged to investigate the possibilities of applying the most recent editions of the standards indicated below.
[ISO/IEC Directives, Part 2] 2016/05. 7.0. Rules for the structure and drafting of International Standards. http://www.iec.ch/members_experts/refdocs/iec/isoiecdir-2%7Bed7.0%7Den.pdf .
[ISO 7498-1] 1994. Information Processing Systems - Open Systems Interconnection - Basic Reference Model.
[ISO 7498-3] 1997. Information Processing Systems - Open Systems Interconnection - Naming and Addressing.
[ISO 8327] 1996. Information Processing Systems - Open Systems Interconnection - Connection Oriented Session Protocol Specification.
[ISO 8649] 1988. Information processing systems - Open Systems Interconnection - Service definition for the Association Control Service Element (ACSE).
[ISO 8650] 1987. Information Processing Systems - Open Systems Interconnection - Protocol Specification for the Association Control Service Element.
[ISO/TR 8509] Information Processing Systems - Open Systems Interconnection - Service Conventions. ISO/TR 8509 has been withdrawn. See ISO/IEC 2382-26:1993 Information technology - Vocabulary - Part 26: Open systems interconnection .
[ISO 8822] 1988. Information processing systems - Open Systems Interconnection - Connection oriented presentation service definition.
[ISO 8823] 1988. Information processing systems - Open Systems Interconnection - Connection Oriented Presentation Protocol Specification.
[ISO 8824] 1990. Information processing systems - Open Systems Interconnection - Specification of Abstract Syntax Notation One (ASN.1).
[ISO 8825] 1990. Information processing systems - Open Systems Interconnection - Specification of Basic Encoding Rules for Abstract Syntax Notation One (ASN.1).
[ISO/IEC 9545] 1994. Information processing systems - Open Systems Interconnection - Application Layer Structure.
[RFC791] September 1981. Internet Protocol - DARPA Internet Protocol Specification. http://tools.ietf.org/html/rfc791 .
[RFC792] September 1981. Internet Control Message Protocol - DARPA Internet Program Protocol Specification. http://tools.ietf.org/html/rfc792 .
[RFC793] September 1981. Transmission Control Program - DARPA Internet Protocol Specification. http://tools.ietf.org/html/rfc793 .
[RFC950] August 1985. Internet Subnetting. http://tools.ietf.org/html/rfc950 .
[RFC1881] December 1995. IPv6 Address Allocation Management. http://tools.ietf.org/html/rfc1881 .
[RFC2460] December 1998. Internet Protocol, Version 6 (IPv6) Specification. http://tools.ietf.org/html/rfc2460 .
| DICOM PS3.8 2024e - Network Communication Support for Message Exchange |
|---|