This Directory Record is based on the specification of Section F.3. It is identified by a Directory Record Type (0004,1430) of Value "RT PLAN". Table F.5-21 lists the set of Keys with their associated Types for such a Directory Record Type. The description of these Keys may be found in the Modules related to the Plan IE of the RT-specific Plan IODs. This Directory Record shall be used to reference an RT Plan SOP Instance or RT Ion Plan SOP Instance. This Type of Directory Record may reference a Lower-Level Directory Entity that includes one or more Directory Records as defined in Table F.4-1.
Table F.5-21. RT Plan Keys
Because Referenced SOP Instance UID in File (0004,1511) may be used as a "pseudo" Directory Record Key (see Table F.3-3), it is not duplicated in this list of Keys.