| DICOM PS3.3 2024e - Information Object Definitions |
|---|
Table C.30.4-1 specifies the Attributes of the Unified Procedure Step Relationship Module, which describe the relationship of a Unified Procedure Step (UPS).
Table C.30.4-1. Unified Procedure Step Relationship Module Attributes
|
Primary identifier for the patient. NoteIn the case of imaging a group of small animals simultaneously, the single value of this identifier corresponds to the identification of the entire group. See also Section C.7.1.4.1.1. See Section C.30.4.1 |
||
|
The type of identifier in the Patient ID (0010,0020). Note
|
||
|
Identification numbers or codes used to identify the patient, which may or may not be human readable, and may or may not have been obtained from an implanted or attached device such as an RFID or barcode. |
||
|
>Include Table 10-18 “Issuer of Patient ID Macro Attributes” |
||
|
The type of identifier in the Patient ID (0010,0020) in this Item. Note
|
||
|
Date of birth of the named patient in the Alternative Calendar (0010,0035). |
||
|
Date of death of the named patient in the Alternative Calendar (0010,0035). |
||
|
The Alternative Calendar used for Patient's Birth Date in Alternative Calendar (0010,0033) and Patient's Death Date in Alternative Calendar (0010,0034). See Section C.7.1.5 for Defined Terms. Required if either Patient's Birth Date in Alternative Calendar (0010,0033) or Patient's Alternative Death Date in Calendar (0010,0034) is present. |
||
|
A photo to confirm the identity of a patient. Only a single Item is permitted in this Sequence. See C.2.2.1.1. |
||
|
>Include Table 10-3b “Referenced Instances and Access Macro Attributes” |
||
|
Identification number of the Visit as assigned by the healthcare provider |
||
|
Identifier of the Assigning Authority that issued the Admission ID. |
||
|
>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
|
Description of admitting diagnosis (diagnoses) for the patient. |
||
|
Reason(s) for this visit by the patient to the facility or provider. |
||
|
Coded reason(s) for this visit by the patient to the facility or provider. |
||
|
Requested Procedures to which the Procedure Step contributes. |
||
|
A departmental Information System generated number that identifies the Imaging Service Request. |
||
|
Identifier of the Assigning Authority that issued the Accession Number. |
||
|
>>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
|
The order number assigned to the Service Request by the party placing the order. |
||
|
Identifier of the Assigning Authority that issued the Placer Order Number. |
||
|
>>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
|
The order number assigned to the Service Request by the party filling the order. |
||
|
Identifier of the Assigning Authority that issued the Filler Order Number. |
||
|
>>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
|
Institution-generated description or classification of the Requested Procedure. |
||
|
Confidentiality Constraints on the Requested Procedure by the party filling the order. |
||
|
Names of the physicians, who are intended recipients of results. |
||
|
Institutional department, unit or service where the request initiated. |
||
|
Institutional department, unit or service where the request initiated. Equivalent to HL7 v2.x ORC-17. See Note 1. |
||
|
Date on which the Service Request was issued by the requester. |
||
|
Time at which the Service Request was issued by the requester. |
||
|
The physician who referred the Patient to the physician or service issuing the Service Request. |
||
|
Canceled procedure step(s) that are replaced by this procedure step. |
||
|
>Include Table 10-11 “SOP Instance Reference Macro Attributes” |
||
For workitems that have a patient as the subject or context, the Patient ID, Issuer of Patient ID, Patient's Name, Patient's Sex and Patient's Birth Date shall have appropriate values.
For workitems that have an identifiable subject that is not a patient, for example a phantom to be scanned or a display to be calibrated, the Patient ID shall be filled with an acceptable pseudo-patient value.
For an object with a hospital asset control number or a manufacturer's serial number, that number might be used as the Patient ID. The Issuer of Patient ID would identify the hospital asset control system or the device manufacturer. Alternatively, it is conceivable that a Patient ID could be generated by the ADT or the local John Doe procedure (to avoid conflicting with an ID assigned to a real patient).
The Patient Name might be set to CT^Phantom or ReadingRoom1Display.
| DICOM PS3.3 2024e - Information Object Definitions |
|---|