The relative URI reference within encapsulated document value shall be encoded as a relative URI reference [RFC3986], with the following restrictions:
The base path (URI) to which the reference is relative is the location where the referencing file would hypothetically be written, were it to be unencapsulated and written to a file, such that the set of related encapsulated documents share the same base path.
The path shall not refer to a higher level in the file system hierarchy (i.e., use of ".." is not permitted).
File name extensions corresponding to executable file types (exe, dll, etc.) are not permitted.