DICOM PS3.2 2024e - Conformance

N.9.5 A.A.5 Basic Directory IOD

Table N.9-50 defines the structure of the Basic Directory IOD.

Table N.9-50. Basic Directory IOD

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

File Set Identification Module

File-set ID

(0004,1130)

GENERATED

Specific Character Set of File-set Descriptor File

(0004,1142)

GENERATED

Directory Information Module

Offset of the First Directory Record of the Root Directory Entity

(0004,1200)

GENERATED

Offset of the Last Directory Record of the Root Directory Entity

(0004,1202)

GENERATED

File-set Consistency Flag

(0004,1212)

GENERATED

Directory Record Sequence

(0004,1220)

GENERATED

>Offset of the Next Directory Record

(0004,1400)

GENERATED

>Record In-use Flag

(0004,1410)

GENERATED

>Offset of Referenced Lower-Level Directory Entity

(0004,1420)

GENERATED

>Directory Record Type

(0004,1430)

GENERATED

>Referenced File ID

(0004,1500)

GENERATED

>Referenced SOP Class UID in File

(0004,1510)

SRC_INSTANCE

>Referenced SOP Instance UID in File

(0004,1511)

SRC_INSTANCE

>Referenced Transfer Syntax UID in File

(0004,1512)

SRC_INSTANCE

Patient Keys

>Specific Character Set

(0008,0005)

GENERATED

>Patient's Name

(0010,0010)

SRC_INSTANCE

>Patient ID

(0010,0020)

SRC_INSTANCE

…

Study Keys

>Study Date

(0008,0020)

SRC_INSTANCE

>Study Time

(0008,0030)

SRC_INSTANCE

>Study Description

(0008,1030)

SRC_INSTANCE

>Study Instance UID

(0020,000D)

SRC_INSTANCE

>Study ID

(0020,0010)

SRC_INSTANCE

>Accession Number

(0008,0050)

SRC_INSTANCE

…

Series Keys

>Specific Character Set

(0008,0005)

GENERATED

>Modality

(0008,0060)

SRC_INSTANCE

>Series Instance UID

(0020,000E)

SRC_INSTANCE

>Series Number

(0020,0011)

SRC_INSTANCE

…

Image Keys

>Specific Character Set

(0008,0005)

GENERATED

>Instance Number

(0020,0013)

SRC_INSTANCE

>Samples per Pixel

(0028,0002)

SRC_INSTANCE

>Photometric Interpretation

(0028,0004)

SRC_INSTANCE

>Rows

(0028,0010)

SRC_INSTANCE

>Columns

(0028,0011)

SRC_INSTANCE

>Bits Allocated

(0028,0100)

SRC_INSTANCE

>Bits Stored

(0028,0101)

SRC_INSTANCE

>High Bit

(0028,0102)

SRC_INSTANCE

>Pixel Representation

(0028,0103)

SRC_INSTANCE

…

SR Document Keys

>Specific Character Set

(0008,0005)

GENERATED

>Instance Number

(0020,0013)

SRC_INSTANCE

>Completion Flag

(0040, A491)

SRC_INSTANCE

>Verification Flag

(0040, A493)

SRC_INSTANCE

>Content Date

(0008,0023)

SRC_INSTANCE

>Content Time

(0008,0033)

SRC_INSTANCE

>Verification DateTime

(0040,A030)

SRC_INSTANCE

>Concept Name Code Sequence

(0040,A043)

SRC_INSTANCE

>>Code Value

(0008,1000)

>>Coding Scheme Designator

(0008,1002)

>>Coding Scheme Version

(0008,1003)

>>Code Meaning

(0008,1004)


DICOM PS3.2 2024e - Conformance