| DICOM PS3.2 2024e - Conformance |
|---|
For the purposes of this Standard the following definitions apply.
This Part makes use of the following terms defined in [ISO 7498-1]:
See [ISO 7498-1].
See [ISO 7498-1].
See [ISO 7498-1].
See [ISO 7498-1].
This Part makes use of the following terms defined in [ISO 8649]:
See [ISO 8649].
See [ISO 8649].
This Part makes use of the following terms defined in [ISO 8822]:
See [ISO 8822].
See [ISO 8822].
See [ISO 8822].
See [ISO 8822].
This Part makes use of the following terms defined in PS3.1:
This Part makes use of the following terms defined in PS3.3:
This Part makes use of the following terms defined in PS3.4:
This Part makes use of the following terms defined in PS3.5:
This Part makes use of the following terms defined in PS3.7:
This Part makes use of the following terms defined in PS3.8:
This Part makes use of the following terms defined in PS3.10:
This Part uses the following definitions:
A SOP Class defined in the DICOM Standard that is used in an implementation with no modifications.
A SOP Class defined in the DICOM Standard extended in an implementation with additional Type 3 Attributes. The additional Attributes may either be drawn from the Data Dictionary in PS3.6, or may be Private Attributes. The semantics of the related Standard SOP Class shall not be modified by the additional Type 3 Attributes when absent. Therefore, the Standard Extended SOP Class utilizes the same UID as the related Standard SOP Class.
A SOP Class derived from a Standard SOP Class that has been specialized in an implementation by additional Type 1, 1C, 2, 2C, or 3 Attributes, by enumeration of specific permitted values for Attributes, or by enumeration of specific permitted Templates. The additional Attributes may either be drawn from the Data Dictionary in PS3.6, or may be Private Attributes. The enumeration of permitted Attribute values or Templates shall be a subset of those permitted in the related Standard SOP Class. Since the semantics of the related Standard SOP Class may be modified by the additional Attributes, a Specialized SOP Class utilizes a Privately Defined UID that differs from the UID for the related Standard SOP Class.
Since a Specialized SOP Class has a different UID than a Standard or Standard Extended SOP Class, other DICOM implementations may not recognize the Specialized SOP Class. Because of this limitation, a Specialized SOP Class should only be used when a Standard or Standard Extended SOP Class would not be appropriate. Before different implementations can exchange Instances in a Specialized SOP Class, the implementations must agree on the UID, content (in particular the additional Type 1, 1C, 2, and 2C Attributes), and semantics of the Specialized SOP Class. A Specialized SOP Class may be used to create a new or experimental SOP Class that is closely related to a Standard SOP Class.
The Association Negotiation for a Specialized SOP Class may include a SOP Class Common Extended Negotiation Sub-Item (as defined in PS3.7) for identification of the Service Class and of the Related General SOP Class from which it was specialized. This may allow a receiving application, without prior agreement on the Specialized SOP Class IOD, to process Instances of that class as if they were instances of a Related General SOP Class.
A SOP Class that is not defined in the DICOM Standard, but is published in an implementation's Conformance Statement.
Since a Private SOP Class is not defined in the DICOM Standard, other DICOM implementations may not recognize the Private SOP Class. Because of this limitation, a Private SOP Class should only be used when a Standard or Standard Extended SOP Class would not be appropriate. In order for different implementations to exchange Instances in a Private SOP Class, the implementations must agree on the UID, content (in particular the Type 1, 1C, 2, and 2C Attributes), and semantics of the Private SOP Class. A Private SOP Class may be used to create a totally new or experimental SOP Class.
An Attribute defined in the Data Dictionary in PS3.6.
An Application Profile defined in the DICOM Standard that is used in an implementation with no modifications.
An Application Profile derived from a Standard Application Profile by incorporating support for additional Standard or Standard Extended SOP Classes.
An Application Profile that is not defined in the DICOM Standard, but is published in an implementation's Conformance Statement.
A mechanism for selecting an appropriate set of choices from the Parts of the DICOM Standard along with corresponding security mechanisms (e.g., encryption algorithms) for the support of security facilities.
A mechanism for mapping and transforming DICOM SR objects to HL7 CDA documents.
This Part makes use of the following terms defined in PS3.18:
This Part makes use of the following terms defined in PS3.18
| DICOM PS3.2 2024e - Conformance |
|---|