DICOM PS3.16 2024d - Content Mapping Resource

CID 8112 Specimen Stain

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

SpecimenStain

FHIR Keyword:

dicom-cid-8112-SpecimenStain

Type:

Extensible

Version:

20240611

UID:

1.2.840.10008.6.1.1050

Table CID 8112. Specimen Stain

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

SCT

255792001

acid phosphatase stain

C-2280A

C0440036

SCT

255793006

Albert's stain

C-2280B

C0440037

SCT

4656000

alcian blue 8GX stain

C-22963

C0001933

SCT

47995002

alcohol soluble nigrosine stain

C-22932

C0303908

SCT

406981005

aldehyde fuchsin stain

C-2286D

C0491984

SCT

54432009

alizarin blue S stain

C-22961

C0303917

SCT

21951008

alizarin cyanine green stain

C-22959

C0303916

SCT

65580004

alizarin red S stain

C-22953

C0051165

SCT

27016007

alizarin yellow GG stain

C-22813

C0303861

SCT

28622002

alizarin yellow R stain

C-22814

C0619792

SCT

406971006

alkaline phosphatase stain

C-2285B

C1318717

SCT

406990003

aniline blue stain

C-2287E

C1321796

SCT

255794000

auramine stain

C-2280C

C0440038

SCT

85066006

azo black stain

C-22873

C0058437

SCT

76048000

azocarmine G (GX) stain

C-22929

C0303907

SCT

35609001

azophloxin stain

C-22842

C0073022

SCT

2159007

azorubin S stain

C-22831

C0002406

SCT

16836001

azure A stain

C-22945

C0052826

SCT

8926000

azure B stain

C-22946

C0052827

SCT

11069001

azure C stain

C-22944

C0052828

SCT

406982003

bauer's chromic acid leucofuchsin stain

C-2286E

C1318723

SCT

27844007

benzo fast scarlet stain

C-22872

C0303882

SCT

255795004

beta-glucuronidase stain

C-2280D

C0440039

SCT

76605005

biebrich scarlet stain

C-22866

C0303878

SCT

44488008

bismark brown R stain

C-22849

C0303872

SCT

85190005

bismark brown Y stain

C-22848

C0303871

SCT

1346008

blue shade eosin stain

C-22921

C0303904

SCT

41750006

brazilin stain

C-22965

C0054031

SCT

8342001

brilliant cresyl blue stain

C-22934

C0054052

SCT

86541009

brilliant crocein stain

C-22869

C0303880

SCT

8429000

brilliant orange stain

C-22865

C0303877

SCT

57753006

brilliant yellow stain

C-22857

C0058441

SCT

406955006

butyrate esterase stain

C-2283C

C1321545

SCT

764166003

carbol fuchsin stain

C0054697

SCT

73892005

carmine stain

C-22971

C0007250

SCT

432003

carminic acid stain

C-22972

C0054801

SCT

37575004

carmoisine A stain

C-22822

C0052799

SCT

38707008

celestine blue B stain

C-22936

C0055019

SCT

255796003

chloroacetate esterase stain

C-2280E

C0440040

SCT

406986000

chromic acid stain

C-2287B

C1321562

SCT

85981002

chromotrope 2R stain

C-22838

C0109683

SCT

10247008

chrysoidine R stain

C-22806

C0109694

SCT

16943008

chrysoidine Y stain

C-22805

C0055663

SCT

406952009

colloidal iron stain

C-22837

C1318877

SCT

45106005

Congo red stain

C-22851

C0009742

SCT

406960005

cresyl echt violet stain

C-22847

C1318879

SCT

406959000

cresyl violet stain

C-22840

C0056484

SCT

68459007

crystal ponceau stain

C-22833

C0303867

SCT

89028002

curcumin stain

C-22966

C0010467

SCT

72572003

diamond black stain

C-22826

C0303866

SCT

11780008

durazol red stain

C-22871

C0303881

SCT

40076005

erie garnet stain

C-22852

C0303873

SCT

58631000

eriochrome blue black SE stain

C-22839

C0059526

SCT

7434003

erythrosin B stain

C-22924

C0014824

SCT

5043000

erythrosin Y stain

C-22923

C0303905

SCT

22931006

Evans blue stain

C-22854

C0015205

SCT

34700000

fast blue B salt stain

C-22883

C0303888

SCT

91295002

fast blue BB salt stain

C-22881

C0060085

SCT

64112001

fast blue RR salt stain

C-22878

C0303885

SCT

89148006

fast garnet GBC salt stain

C-22882

C0303887

SCT

24167004

fast green FCF stain

C-22886

C0060087

SCT

40718007

fast red B salt stain

C-22876

C0303883

SCT

47486002

fast red ITR stain

C-22877

C0303884

SCT

76633005

fast red TR salt stain

C-22875

C0950478

SCT

88660000

fast sulfon black F stain

C-22867

C0303879

SCT

72371006

fast violet B salt stain

C-22879

C0303886

SCT

76439002

fat red 7B stain

C-22859

C0117300

SCT

255797007

Feulgen reaction stain

C-2280F

C0440041

SCT

255798002

field's stain

C-22810

C0440042

SCT

255799005

Flagellar stain

C-22816

C0440043

SCT

35352008

fluorescent stain

C-22A00

C0303920

SCT

406980006

fouchet stain

C-2286C

C1318722

SCT

60920007

fuchsin acid stain

C-22902

C0252873

SCT

50062004

fuchsin basic stain

C-22889

C0073578

SCT

8836009

gallocyanine stain

C-22935

C0061013

SCT

373646006

giemsa stain

F-61968

C0017542

SCT

385484003

gram stain

C-22830

C0061856

SCT

406983008

hansel stain

C-2286F

C1318724

SCT

75956008

hematein stain

C-22967

C0062204

SCT

12710003

hematoxylin stain

C-22968

C0018964

SCT

255800009

immunofluorescent stain

C-22817

C0183489

SCT

406972004

India ink stain

C-2285C

C0123471

SCT

412548006

indigo carmine

F-61F48

C0021219

SCT

11727009

indophenol from naphthol stain

C-22927

C0303906

SCT

47030008

insoluble berlin blue stain

C-22974

C0303918

SCT

68263003

janus green B stain

C-22804

C0064136

SCT

255801008

Jenner-Giemsa stain

C-22818

C0440044

SCT

29342009

kenacid blue R stain

C-22899

C0303892

SCT

35724001

lacmoid stain

C-22942

C0303910

SCT

255802001

Leishman stain

C-22819

C0440052

SCT

89139001

light green SF stain

C-22887

C0064970

SCT

6701008

lissamine fast red B stain

C-22841

C0303868

SCT

25079009

lissamine fast yellow stain

C-22843

C0303869

SCT

38543004

lissamine green B stain

C-22914

C0061890

SCT

111102009

lissamine rhodamine stain

C-22917

C0303900

SCT

406958008

luxol fast blue stain

C-2283F

C0065274

SCT

27120008

malachite green stain

C-22890

C0065555

SCT

406953004

Mallory bleach stain

C-2283A

C1318878

SCT

46139004

martius yellow stain

C-22802

C0303860

SCT

255803006

may-Grunwald giemsa stain

C-2281A

C0065757

SCT

24516006

meldola blue stain

C-22937

C0065912

SCT

54791001

metanil yellow stain

C-22811

C0066052

SCT

9010006

methyl blue stain

C-22907

C0303897

SCT

255804000

methyl green pyronin stain

C-2281B

C0440045

SCT

42248000

methyl orange stain

C-22809

C0066274

SCT

13744001

methyl red stain

C-22808

C0066279

SCT

387239001

methyl violet stain

F-61A76

C0017440

SCT

6725000

methylene blue stain

C-22947

C0025746

SCT

406961009

methylene violet stain

C-2284A

C0492805

SCT

31260003

methylene violet stain (Bernthsen)

C-22952

C0303911

SCT

406991004

modified trichrome stain

C-2287F

C1318726

SCT

406964001

mucicarmine stain

C-2284B

C0066912

SCT

255805004

myeloperoxidase stain

C-2281C

C0440053

SCT

16788000

naphthalene black 12B stain

C-22846

C0303870

SCT

14958002

naphthol green B stain

C-22801

C0303859

SCT

111101002

naphthol yellow S stain

C-22803

C0068424

SCT

406973009

naphthol-AS-D-chloracetate esterase stain

C-2285D

C1318718

SCT

67956008

neutral red stain

C-22928

C0027941

SCT

255806003

neutrophil alkaline phosphatase stain

C-2281D

C0440046

SCT

31714001

new fuchsin stain

C-22891

C0068661

SCT

406965000

night blue stain

C-2284C

C0068751

SCT

77073008

nile blue stain

C-22941

C0068765

SCT

86750008

nitrazine yellow stain

C-22823

C0068806

SCT

255807007

nonspecific esterase stain

C-2281E

C0440047

SCT

78869007

nuclear fast red stain

C-22955

C0303913

SCT

40808006

oil red O stain

C-22863

C0069388

SCT

54221006

orange G stain

C-22832

C0069591

SCT

25941002

orange II stain

C-22824

C0069592

SCT

406966004

orcein stain

C-2284D

C0069596

SCT

5442001

page blue 83 stain

C-22901

C0303893

SCT

2088005

page blue G-90 stain

C-22898

C0056270

SCT

48540004

patent blue V sodium salt stain

C-22885

C0116465

SCT

255808002

periodic acid Schiff stain

C-2281F

C0440048

SCT

410457007

permethrin

C-2310F

C0070455

SCT

406974003

peroxidase stain

C-2285E

C1318719

SCT

71957009

phloxin B stain

C-22922

C0031567

SCT

406967008

phosphotungstic acid-hematoxylin stain

C-2284E

C0491956

SCT

65730007

ponceau 3R stain

C-22829

C0071718

SCT

89856006

ponceau S stain

C-22868

C0071720

SCT

70520000

ponceau xylidine stain

C-22828

C0950345

SCT

89577003

pontamine sky blue 5BX stain

C-22855

C0303874

SCT

80305003

pontamine sky blue 6BX stain

C-22856

C0303875

SCT

34763001

potassium hydroxide stain

C-10330

C0071767

SCT

24900003

procion brilliant blue MRS stain

C-22956

C0303914

SCT

406993001

protargol S stain

C-2288A

C0492806

SCT

406452004

Prussian blue stain

C-13036

C0060234

SCT

406968003

quinacrine fluorescent stain

C-2284F

C1318715

SCT

406977005

rhodamine stain

C-2286A

C0600322

SCT

255810000

Romanowsky stain

C-2282A

C0440055

SCT

408742009

rose bengal stain

R-10223

C0035857

SCT

15529003

rosolic acid sodium salt stain

C-22908

C0303898

SCT

38271009

saffron stain

C-22964

C0162753

SCT

406988004

safranin stain

F-61DA5

C0073949

SCT

406985001

silver nitrate stain

C-2287A

C1321600

SCT

406951002

silver stain

C-22836

C1318876

SCT

51567006

sirius red F3B stain

C-22874

C0071047

SCT

43549000

solochrome azurine (BS) stain

C-22912

C0303899

SCT

11201005

solochrome black 6B stain

C-22821

C0303864

SCT

25091000

solochrome cyanine R stain

C-22909

C0074807

SCT

38902009

solochrome dark blue stain

C-22825

C0054495

SCT

64991008

soluble berlin blue stain

C-22975

C0303919

SCT

11645004

spirit soluble aniline blue stain

C-22906

C1260876

SCT

83600004

spirit soluble eosin stain

C-22920

C0303903

SCT

255811001

spore stain

C-2282B

C0440049

SCT

314900004

Sudan stain

C-2282D

C1282434

SCT

22968009

sunset yellow FCF stain

C-22827

C0060120

SCT

21592006

tartrazine stain

C-22844

C0039329

SCT

406975002

terminal deoxynucleotidyl transferase stain

C-2285F

C0687124

SCT

406995008

thioflavine S stain

C-2288D

C0952039

SCT

61068006

thioflavine T stain

C-22926

C0076466

SCT

12001002

thionine stain

C-22943

C0076494

SCT

84217005

titan yellow stain

C-22845

C0076731

SCT

406989007

trichrome stain

C-2287D

C0077066

SCT

35094004

tropaeolin O stain

C-22815

C0303863

SCT

53511009

tropaeolin OO stain

C-22812

C0077384

SCT

60441008

trypan blue stain

C-22853

C0041213

SCT

406957003

Van Gieson stain

C-2283E

C0491963

SCT

406992006

verhoeff's hematoxylin stain

C-22880

C1319311

SCT

20230008

vital new red stain

C-22858

C0303876

SCT

88625006

water soluble aniline blue stain

C-22904

C1321796

SCT

58755002

water soluble anthracene brown stain

C-22954

C0303912

SCT

12119009

water soluble nigrosine stain

C-22933

C0303909

SCT

60739006

waxoline blue stain

C-22957

C0303915

SCT

409549005

wayson stain

F-61E5A

C1443889

SCT

373682001

wright stain

F-619B7

C1261259

SCT

55831004

xylene cyanol FF stain

C-22888

C0303889

SCT

255813003

Ziehl-Neelsen stain

C-2282C

C0440051

SCT

29252006

acridine orange stain

C-22A08

C0001185

SCT

17693003

acriflavine stain

C-22A07

C0001187

SCT

84656005

atebrin FS stain

C-22A03

C0303922

SCT

73251007

auramine G stain

C-22A02

C0303921

SCT

81397005

auramine O stain

C-22A01

C0878260

SCT

49687009

coriphosphine stain

C-22A11

C0056341

SCT

85596006

fluorescein stain

C-22A05

C0060520

SCT

108880002

fluorexon stain

C-22AA1

C0060549

SCT

27671009

rhodamine B stain

C-22A04

C0073194

SCT

25351006

Fluorescein sodium stain

C-22A06

C0147866

SCT

36572009

Sudan black B stain

C-22864

C0075489

SCT

310805002

Sudan black stain

C-2282E

C0588374

SCT

10740006

Sudan blue stain

C-22958

C0075490

SCT

12030009

Sudan II stain

C-22807

C0075492

SCT

39777001

Sudan III stain

C-22861

C0075491

SCT

69133007

Sudan IV stain

C-22862

C0074127

SCT

76925007

alkali blue 5B (4B) stain

C-22903

C0303894

SCT

63929007

alkali blue 6B stain

C-22905

C0303895

SCT

34128002

chrome azurol S stain

C-22911

C0055614

SCT

17172002

dibromofluorescein stain

C-22918

C0303901

SCT

65445001

ethyl violet stain

C-22897

C0059784

SCT

22021002

methyl green stain

C-22896

C0025701

SCT

15896008

methyl violet 2B stain

C-22892

C0303890

SCT

14544006

methyl violet 6B stain

C-22894

C0303891

SCT

76001002

pyronine B stain

C-22916

C0072769

SCT

43106008

pyronine G stain

C-22915

C0034316

SCT

29522004

toluidine blue stain

C-22951

C0040380

SCT

82682000

victoria blue 4R stain

C-22895

C0078233

SCT

22749001

victoria blue B stain

C-22913

C0078234

SCT

36879007

water soluble eosin stain

C-22919

C0303902


DICOM PS3.16 2024d - Content Mapping Resource