DICOM PS3.16 2024d - Content Mapping Resource

CID 7483 Common Anatomic Regions for Animal

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

CommonAnatomicRegionsForAnimal

FHIR Keyword:

dicom-cid-7483-CommonAnatomicRegionsForAnimal

Type:

Extensible

Version:

20220922

UID:

1.2.840.10008.6.1.815

Table CID 7483. Common Anatomic Regions for Animal

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

Notes

SCT

818981001

Abdomen

SCT

42694008

All legs

T-D8030

C0230331

SCT

62555009

Atlantal-axial joint

T-15317

C0224585

SCT

20292002

Atlanto-occipital joint

T-15311

C0004169

SCT

89837001

Bladder

T-74000

C0005682

SCT

82474009

Calcaneal tubercle

T-12771

C0223921

See Note 1.

SCT

8205005

Carpus

T-D8600

C0043262

See Note 2.

SCT

122494005

Cervical spine

T-11501

C0728985

SCT

1217257000

Cervico-thoracic spine

SCT

816094009

Chest

SCT

416550000

Chest and Abdomen

R-FAB55

C1442171

SCT

18149002

Coccygeal vertrebrae

T-11B00

C0223616

See Note 3.

SCT

71854001

Colon

T-59300

C0009368

SCT

82680008

Digit

T-D0310

C0582802

UMLS

C3669027

Distal phalanx

C3669027

SCT

16953009

Elbow joint

T-15430

C0013770

SCT

38266002

Entire body

T-D0010

C0229960

SCT

32849002

Esophagus

T-56000

C0014876

SCT

71341001

Femur

T-12710

C0015811

SCT

13190002

Fetlock of forelimb

T-D8640

C0521445

SCT

113351006

Fetlock of hindlimb

T-D9540

C0521446

SCT

419176008

Forefoot

T-D04F2

C1630649

SCT

55060009

Frontal sinus

T-22200

C0016734

SCT

416804009

Hindfoot

T-D9713

C0230459

SCT

24136001

Hip joint

T-15710

C0019558

SCT

85050009

Humerus

T-12410

C0020164

SCT

122496007

Lumbar spine

T-11503

C0024091

SCT

1217253001

Lumbo-sacral spine

SCT

91609006

Mandible

T-11180

C0024687

SCT

88176008

Mandibular dental arch

T-54170

C0227027

SCT

442274007

Mandibular incisor teeth

T-540EE

C2711599

SCT

39481002

Maxillary dental arch

T-54160

C0227026

SCT

442100006

Maxillary incisor teeth

T-540ED

C2711204

SCT

36455000

Metacarpus

T-12540

C0025526

SCT

280711000

Metatarsus

T-12847

C0025590

SCT

2095001

Nasal sinus

T-22000

C0030471

SCT

30518006

Navicular of forefoot

T-12450

C0223724

See Note 4.

SCT

75772009

Navicular of hindfoot

T-12800

C0223947

See Note 4.

SCT

363654007

Orbital structure

T-D14AE

C0029180

SCT

31329001

Pastern of forefoot

T-D8650

C0230368

SCT

18525008

Pastern of hindfoot

T-D9550

C0230455

SCT

64234005

Patella

T-12730

C0030647

SCT

816092008

Pelvis

SCT

110535000

Radius and ulna

T-12403

C1267080

SCT

54735007

Sacrum

T-11AD0

C0036037

SCT

16982005

Shoulder

T-D2220

C0037004

SCT

89546000

Skull

T-11100

C0037303

SCT

116010006

Stiffle

T-15728

C1456798

SCT

108371006

Tarsus

T-12761

C0039316

See Note 5.

SCT

122495006

Thoracic spine

T-11502

C0581269

SCT

1217256009

Thoraco-lumbar spine

SCT

110536004

Tibia and fibula

T-12701

C0224692

SCT

62834003

Upper gastro-intestinal tract

T-50110

C3203348

SCT

13648007

Urethra

T-75000

C0041967

SCT

431938005

Urinary tract

T-7000C

C2316969

SCT

53036007

Wing

T-D8040

C0043189


Note

  1. (82474009, SCT, "Calcaneal tubercle") is used in preference to (80144004, SCT, "Calcaneus").

  2. (8205005, SCT, "Carpus") is used in preference to carpal (wrist) joint.

  3. (18149002, SCT, "Coccygeal vertrebrae") is used in preference to (64688005, SCT, "Coccyx") as used for humans, since the animal possess a tail.

  4. (75772009, SCT, "Navicular of hindfoot") assumes correspondence between equine hindfoot and human navicular, and (30518006, SCT, "Navicular of forefoot") the equine forefoot navicular and human scaphoid (distal sesamoid).

  5. (108371006, SCT, "Tarsus") is used for the hock joint.

  6. In a prior version of this table, the code SRT: T-D8300 was used for (16953009, SCT, "Elbow Joint"). Although there is minimal possibility of misinterpretation with SOP Instances that may include the deprecated use, receiving applications should be aware of this change; see Annex J.

DICOM PS3.16 2024d - Content Mapping Resource