DICOM PS3.6 2024d - Data Dictionary

A Registry of DICOM Unique Identifiers (UIDs) (Normative)

Table A-1 lists the UID values that are registered and used throughout the Parts of the DICOM Standard. This central registry ensures that when additional UIDs are assigned, non-duplicate values are assigned. For retired UIDs, the edition of the Standard in parentheses is the edition in which the item last appeared before it was retired.

Table A-1. UID Values

UID Value

UID Name

UID ​Keyword

UID Type

Part

1.2.840.10008.1.​1

Verification SOP Class

Verification

SOP Class

PS3.4

1.2.840.10008.1.​2

Implicit VR Little Endian: Default Transfer Syntax for DICOM

Implicit​VR​Little​Endian

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​1

Explicit VR Little Endian

Explicit​VR​Little​Endian

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​1.98

Encapsulated Uncompressed Explicit VR Little Endian

Encapsulated​Uncompressed​Explicit​VR​Little​Endian

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​1.​99

Deflated Explicit VR Little Endian

Deflated​Explicit​VR​Little​Endian

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​2

Explicit VR Big Endian (Retired)

Explicit​VR​Big​Endian

Transfer Syntax

PS3.5 (2011)

1.2.840.10008.1.2.​4.​50

JPEG Baseline (Process 1): Default Transfer Syntax for Lossy JPEG 8 Bit Image Compression

JPEG​Baseline​8​Bit

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​51

JPEG Extended (Process 2 & 4): Default Transfer Syntax for Lossy JPEG 12 Bit Image Compression (Process 4 only)

JPEG​Extended​12​Bit

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​52

JPEG Extended (Process 3 & 5) (Retired)

JPEG​Extended35

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​53

JPEG Spectral Selection, Non-Hierarchical (Process 6 & 8) (Retired)

JPEG​Spectral​Selection​Non​Hierarchical68

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​54

JPEG Spectral Selection, Non-Hierarchical (Process 7 & 9) (Retired)

JPEG​Spectral​Selection​Non​Hierarchical79

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​55

JPEG Full Progression, Non-Hierarchical (Process 10 & 12) (Retired)

JPEG​Full​Progression​Non​Hierarchical1012

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​56

JPEG Full Progression, Non-Hierarchical (Process 11 & 13) (Retired)

JPEG​Full​Progression​Non​Hierarchical1113

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​57

JPEG Lossless, Non-Hierarchical (Process 14)

JPEG​Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​58

JPEG Lossless, Non-Hierarchical (Process 15) (Retired)

JPEG​Lossless​Non​Hierarchical​15

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​59

JPEG Extended, Hierarchical (Process 16 & 18) (Retired)

JPEG​Extended​Hierarchical​1618

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​60

JPEG Extended, Hierarchical (Process 17 & 19) (Retired)

JPEG​Extended​Hierarchical​1719

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​61

JPEG Spectral Selection, Hierarchical (Process 20 & 22) (Retired)

JPEG​Spectral​Selection​Hierarchical2022

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​62

JPEG Spectral Selection, Hierarchical (Process 21 & 23) (Retired)

JPEG​Spectral​Selection​Hierarchical2123

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​63

JPEG Full Progression, Hierarchical (Process 24 & 26) (Retired)

JPEG​Full​Progression​Hierarchical2426

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​64

JPEG Full Progression, Hierarchical (Process 25 & 27) (Retired)

JPEG​Full​Progression​Hierarchical2527

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​65

JPEG Lossless, Hierarchical (Process 28) (Retired)

JPEG​Lossless​Hierarchical​28

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​66

JPEG Lossless, Hierarchical (Process 29) (Retired)

JPEG​Lossless​Hierarchical​29

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​70

JPEG Lossless, Non-Hierarchical, First-Order Prediction (Process 14 [Selection Value 1]): Default Transfer Syntax for Lossless JPEG Image Compression

JPEG​Lossless​SV1

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​80

JPEG-LS Lossless Image Compression

JPEG​LS​Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​81

JPEG-LS Lossy (Near-Lossless) Image Compression

JPEG​LS​Near​Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​90

JPEG 2000 Image Compression (Lossless Only)

JPEG​2000Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​91

JPEG 2000 Image Compression

JPEG​2000

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​92

JPEG 2000 Part 2 Multi-component Image Compression (Lossless Only)

JPEG​2000MCLossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​93

JPEG 2000 Part 2 Multi-component Image Compression

JPEG​2000MC

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​94

JPIP Referenced

JPIP​Referenced

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​95

JPIP Referenced Deflate

JPIP​Referenced​Deflate

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​100

MPEG2 Main Profile / Main Level

MPEG2​MPML

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​100.1

Fragmentable MPEG2 Main Profile / Main Level

MPEG2​MPMLF

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​101

MPEG2 Main Profile / High Level

MPEG2​MPHL

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​101.1

Fragmentable MPEG2 Main Profile / High Level

MPEG2​MPHLF

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​102

MPEG-4 AVC/H.264 High Profile / Level 4.1

MPEG4​HP41

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​102.1

Fragmentable MPEG-4 AVC/H.264 High Profile / Level 4.1

MPEG4​HP41F

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​103

MPEG-4 AVC/H.264 BD-compatible High Profile / Level 4.1

MPEG4​HP41BD

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​103.1

Fragmentable MPEG-4 AVC/H.264 BD-compatible High Profile / Level 4.1

MPEG4​HP41BDF

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​104

MPEG-4 AVC/H.264 High Profile / Level 4.2 For 2D Video

MPEG4​HP422D

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​104.1

Fragmentable MPEG-4 AVC/H.264 High Profile / Level 4.2 For 2D Video

MPEG4​HP422DF

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​105

MPEG-4 AVC/H.264 High Profile / Level 4.2 For 3D Video

MPEG4​HP423D

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​105.1

Fragmentable MPEG-4 AVC/H.264 High Profile / Level 4.2 For 3D Video

MPEG4​HP423DF

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​106

MPEG-4 AVC/H.264 Stereo High Profile / Level 4.2

MPEG4​HP42STEREO

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​106.1

Fragmentable MPEG-4 AVC/H.264 Stereo High Profile / Level 4.2

MPEG4​HP42STEREOF

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.107

HEVC/H.265 Main Profile / Level 5.1

HEVC​MP51

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.108

HEVC/H.265 Main 10 Profile / Level 5.1

HEVC​M10P51

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​110

JPEG XL Lossless

JPEG​XL​Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​111

JPEG XL JPEG Recompression

JPEG​XL​JPEG​Recompression

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​112

JPEG XL

JPEG​XL

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​201

High-Throughput JPEG 2000 Image Compression (Lossless Only)

HTJ2K​Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.202

High-Throughput JPEG 2000 with RPCL Options Image Compression (Lossless Only)

HTJ2K​Lossless​RPCL

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​203

High-Throughput JPEG 2000 Image Compression

HTJ2K

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​204

JPIP HTJ2K Referenced

JPIP​HTJ2K​Referenced

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​205

JPIP HTJ2K Referenced Deflate

JPIP​HTJ2K​Referenced​Deflate

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​5

RLE Lossless

RLE​Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​6.​1

RFC 2557 MIME encapsulation (Retired)

RFC​2557​MIME​Encapsulation

Transfer Syntax

PS3.10 (2018b)

1.2.840.10008.1.2.​6.​2

XML Encoding (Retired)

XML​Encoding

Transfer Syntax

PS3.10 (2018b)

1.2.840.10008.1.2.7.1

SMPTE ST 2110-20 Uncompressed Progressive Active Video

SMPTE​ST​211020​Uncompressed​Progressive​Active​Video

Transfer Syntax

PS3.5

1.2.840.10008.1.2.7.2

SMPTE ST 2110-20 Uncompressed Interlaced Active Video

SMPTE​ST​211020​Uncompressed​Interlaced​Active​Video

Transfer Syntax

PS3.5

1.2.840.10008.1.2.7.3

SMPTE ST 2110-30 PCM Digital Audio

SMPTE​ST​211030​PCMDigital​Audio

Transfer Syntax

PS3.5

1.2.840.10008.1.​3.​10

Media Storage Directory Storage

Media​Storage​Directory​Storage

SOP Class

PS3.4

1.2.840.10008.1.​5.​1

Hot Iron Color Palette SOP Instance

Hot​Iron​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​2

PET Color Palette SOP Instance

PET​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​3

Hot Metal Blue Color Palette SOP Instance

Hot​Metal​Blue​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​4

PET 20 Step Color Palette SOP Instance

PET​20​Step​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​5

Spring Color Palette SOP Instance

Spring​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​6

Summer Color Palette SOP Instance

Summer​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​7

Fall Color Palette SOP Instance

Fall​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​8

Winter Color Palette SOP Instance

Winter​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​9

Basic Study Content Notification SOP Class (Retired)

Basic​Study​Content​Notification

SOP Class

PS3.4 (2004)

1.2.840.10008.1.​20

Papyrus 3 Implicit VR Little Endian (Retired)

Papyrus​3​Implicit​VR​Little​Endian

Transfer Syntax

(2015c)

1.2.840.10008.1.​20.​1

Storage Commitment Push Model SOP Class

Storage​Commitment​Push​Model

SOP Class

PS3.4

1.2.840.10008.1.20.​1.​1

Storage Commitment Push Model SOP Instance

Storage​Commitment​Push​Model​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.1.​20.​2

Storage Commitment Pull Model SOP Class (Retired)

Storage​Commitment​Pull​Model​

SOP Class

PS3.4 (2001)

1.2.840.10008.1.20.​2.​1

Storage Commitment Pull Model SOP Instance (Retired)

Storage​Commitment​Pull​Model​Instance

Well-known SOP Instance

PS3.4 (2001)

1.2.840.10008.1.​40

Procedural Event Logging SOP Class

Procedural​Event​Logging

SOP Class

PS3.4

1.2.840.10008.1.​40.​1

Procedural Event Logging SOP Instance

Procedural​Event​Logging​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.1.​42

Substance Administration Logging SOP Class

Substance​Administration​Logging

SOP Class

PS3.4

1.2.840.10008.1.​42.​1

Substance Administration Logging SOP Instance

Substance​Administration​Logging​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.2.​6.​1

DICOM UID Registry

DCMUID

DICOM UIDs as a Coding Scheme

PS3.6

1.2.840.10008.2.​16.​4

DICOM Controlled Terminology

DCM

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​5

Adult Mouse Anatomy Ontology

MA

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​6

Uberon Ontology

UBERON

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​7

Integrated Taxonomic Information System (ITIS) Taxonomic Serial Number (TSN)

ITIS_TSN

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​8

Mouse Genome Initiative (MGI)

MGI

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​9

Pub​Chem Compound CID

PUBCHEM_CID

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​10

Dublin Core

DC

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​11

New York University Melanoma Clinical Cooperative Group

NYUMCCG

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​12

Mayo Clinic Non-radiological Images Specific Body Structure Anatomical Surface Region Guide

MAYONRISBSASRG

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​13

Image Biomarker Standardisation Initiative

IBSI

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​14

Radiomics Ontology

RO

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​15

RadElement

RADELEMENT

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​16

ICD-11

I11

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​17

Unified numbering system (UNS) for metals and alloys

UNS

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​18

Research Resource Identification

RRID

Coding Scheme

PS3.16

1.2.840.10008.3.1.​1.​1

DICOM Application Context Name

DICOM​Application​Context

Application Context Name

PS3.7

1.2.840.10008.3.1.2.​1.​1

Detached Patient Management SOP Class (Retired)

Detached​Patient​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​1.​4

Detached Patient Management Meta SOP Class (Retired)

Detached​Patient​Management​Meta

Meta SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​2.​1

Detached Visit Management SOP Class (Retired)

Detached​Visit​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​3.​1

Detached Study Management SOP Class (Retired)

Detached​Study​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​3.​2

Study Component Management SOP Class (Retired)

Study​Component​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​3.​3

Modality Performed Procedure Step SOP Class

Modality​Performed​Procedure​Step

SOP Class

PS3.4

1.2.840.10008.3.1.2.​3.​4

Modality Performed Procedure Step Retrieve SOP Class

Modality​Performed​Procedure​Step​Retrieve

SOP Class

PS3.4

1.2.840.10008.3.1.2.​3.​5

Modality Performed Procedure Step Notification SOP Class

Modality​Performed​Procedure​Step​Notification

SOP Class

PS3.4

1.2.840.10008.3.1.2.​5.​1

Detached Results Management SOP Class (Retired)

Detached​Results​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​5.​4

Detached Results Management Meta SOP Class (Retired)

Detached​Results​Management​Meta

Meta SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​5.​5

Detached Study Management Meta SOP Class (Retired)

Detached​Study​Management​Meta

Meta SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​6.​1

Detached Interpretation Management SOP Class (Retired)

Detached​Interpretation​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.4.​2

Storage Service Class

Storage

Service Class

PS3.4

1.2.840.10008.5.1.​1.​1

Basic Film Session SOP Class

Basic​Film​Session

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​2

Basic Film Box SOP Class

Basic​Film​Box

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​4

Basic Grayscale Image Box SOP Class

Basic​Grayscale​Image​Box

SOP Class

PS3.4

1.2.840.10008.5.1.1.​4.​1

Basic Color Image Box SOP Class

Basic​Color​Image​Box

SOP Class

PS3.4

1.2.840.10008.5.1.1.​4.​2

Referenced Image Box SOP Class (Retired)

Referenced​Image​Box

SOP Class

PS3.4 (1998)

1.2.840.10008.5.1.​1.​9

Basic Grayscale Print Management Meta SOP Class

Basic​Grayscale​Print​Management​Meta

Meta SOP Class

PS3.4

1.2.840.10008.5.1.1.​9.​1

Referenced Grayscale Print Management Meta SOP Class (Retired)

Referenced​Grayscale​Print​Management​Meta

Meta SOP Class

PS3.4 (1998)

1.2.840.10008.5.1.​1.​14

Print Job SOP Class

Print​Job

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​15

Basic Annotation Box SOP Class

Basic​Annotation​Box

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​16

Printer SOP Class

Printer

SOP Class

PS3.4

1.2.840.10008.5.1.1.​16.​376

Printer Configuration Retrieval SOP Class

Printer​Configuration​Retrieval

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​17

Printer SOP Instance

Printer​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.1.​17.​376

Printer Configuration Retrieval SOP Instance

Printer​Configuration​Retrieval​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.​1.​18

Basic Color Print Management Meta SOP Class

Basic​Color​Print​Management​Meta

Meta SOP Class

PS3.4

1.2.840.10008.5.1.1.​18.​1

Referenced Color Print Management Meta SOP Class (Retired)

Referenced​Color​Print​Management​Meta

Meta SOP Class

PS3.4 (1998)

1.2.840.10008.5.1.​1.​22

VOI LUT Box SOP Class

VOI​LUT​Box

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​23

Presentation LUT SOP Class

Presentation​LUT

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​24

Image Overlay Box SOP Class (Retired)

Image​Overlay​Box

SOP Class

PS3.4 (1998)

1.2.840.10008.5.1.1.​24.​1

Basic Print Image Overlay Box SOP Class (Retired)

Basic​Print​Image​Overlay​Box

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​25

Print Queue SOP Instance (Retired)

Print​Queue​Instance

Well-known SOP Instance

PS3.4 (2004)

1.2.840.10008.5.1.​1.​26

Print Queue Management SOP Class (Retired)

Print​Queue​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​27

Stored Print Storage SOP Class (Retired)

Stored​Print​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​29

Hardcopy Grayscale Image Storage SOP Class (Retired)

Hardcopy​Grayscale​Image​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​30

Hardcopy Color Image Storage SOP Class (Retired)

Hardcopy​Color​Image​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​31

Pull Print Request SOP Class (Retired)

Pull​Print​Request

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​32

Pull Stored Print Management Meta SOP Class (Retired)

Pull​Stored​Print​Management​Meta

Meta SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​33

Media Creation Management SOP Class UID

Media​Creation​Management

SOP Class

PS3.4

1.2.840.10008.5.1.1.40

Display System SOP Class

Display​System

SOP Class

PS3.4

1.2.840.10008.5.1.1.40.1

Display System SOP Instance

Display​System​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.4.1.​1.​1

Computed Radiography Image Storage

Computed​Radiography​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​1.​1

Digital X-Ray Image Storage - For Presentation

Digital​X​Ray​Image​​StorageFor​Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.1.​1.​1

Digital X-Ray Image Storage - For Processing

Digital​X​Ray​Image​​StorageFor​Processing

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​1.​2

Digital Mammography X-Ray Image Storage - For Presentation

Digital​Mammography​X​Ray​Image​​StorageFor​Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.1.​2.​1

Digital Mammography X-Ray Image Storage - For Processing

Digital​Mammography​X​Ray​Image​​StorageFor​Processing

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​1.​3

Digital Intra-Oral X-Ray Image Storage - For Presentation

Digital​Intra​Oral​X​Ray​Image​​StorageFor​Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.1.​3.​1

Digital Intra-Oral X-Ray Image Storage - For Processing

Digital​Intra​Oral​X​Ray​Image​​StorageFor​Processing

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​2

CT Image Storage

CT​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​2.​1

Enhanced CT Image Storage

Enhanced​CT​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​2.​2

Legacy Converted Enhanced CT Image Storage

Legacy​Converted​Enhanced​CT​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​3

Ultrasound Multi-frame Image Storage (Retired)

Ultrasound​Multi​Frame​Image​Storage​Retired

SOP Class

PS3.4 (1993)

1.2.840.10008.​5.​1.​4.​1.​1.​3.​1

Ultrasound Multi-frame Image Storage

Ultrasound​Multi​Frame​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​4

MR Image Storage

MR​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​1

Enhanced MR Image Storage

Enhanced​MR​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​2

MR Spectroscopy Storage

MR​Spectroscopy​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​3

Enhanced MR Color Image Storage

Enhanced​MR​Color​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​4

Legacy Converted Enhanced MR Image Storage

Legacy​Converted​Enhanced​MR​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​5

Nuclear Medicine Image Storage (Retired)

Nuclear​Medicine​Image​Storage​Retired

SOP Class

PS3.4 (1993)

1.2.840.10008.5.1.4.1.​1.​6

Ultrasound Image Storage (Retired)

Ultrasound​Image​Storage​Retired

SOP Class

PS3.4 (1993)

1.2.840.10008.​5.​1.​4.​1.​1.​6.​1

Ultrasound Image Storage

Ultrasound​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​6.​2

Enhanced US Volume Storage

Enhanced​US​Volume​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​6.​3

Photoacoustic Image Storage

Photoacoustic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​7

Secondary Capture Image Storage

Secondary​Capture​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​1

Multi-frame Single Bit Secondary Capture Image Storage

Multi​Frame​Single​Bit​Secondary​Capture​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​2

Multi-frame Grayscale Byte Secondary Capture Image Storage

Multi​Frame​Grayscale​Byte​Secondary​Capture​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​3

Multi-frame Grayscale Word Secondary Capture Image Storage

Multi​Frame​Grayscale​Word​Secondary​Capture​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​4

Multi-frame True Color Secondary Capture Image Storage

Multi​Frame​True​Color​Secondary​Capture​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​8

Standalone Overlay Storage (Retired)

Standalone​Overlay​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.​1.​9

Standalone Curve Storage (Retired)

Standalone​Curve​​​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.​5.​1.​4.​1.​1.​9.​1

Waveform Storage - Trial (Retired)

Waveform​​Storage​Trial

SOP Class

PS3.4 (2007)

1.2.840.10008.​5.​1.​4.​1.​1.9.​1.​1

12-lead ECG Waveform Storage

Twelve​Lead​ECG​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​1.​2

General ECG Waveform Storage

General​ECG​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​1.​3

Ambulatory ECG Waveform Storage

Ambulatory​ECG​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​1.​4

General 32-bit ECG Waveform Storage

General​32bit​ECG​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​2.​1

Hemodynamic Waveform Storage

Hemodynamic​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​3.​1

Cardiac Electrophysiology Waveform Storage

Cardiac​Electrophysiology​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​4.​1

Basic Voice Audio Waveform Storage

Basic​Voice​Audio​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​4.​2

General Audio Waveform Storage

General​Audio​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​5.​1

Arterial Pulse Waveform Storage

Arterial​Pulse​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​6.​1

Respiratory Waveform Storage

Respiratory​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​6.​2

Multi-channel Respiratory Waveform Storage

Multi​channel​Respiratory​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​7.​1

Routine Scalp Electroencephalogram Waveform Storage

Routine​Scalp​Electroencephalogram​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​7.​2

Electromyogram Waveform Storage

Electromyogram​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​7.​3

Electrooculogram Waveform Storage

Electrooculogram​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​7.​4

Sleep Electroencephalogram Waveform Storage

Sleep​Electroencephalogram​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​8.​1

Body Position Waveform Storage

Body​Position​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​10

Standalone Modality LUT Storage (Retired)

Standalone​Modality​LUT​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.​1.​11

Standalone VOI LUT Storage (Retired)

Standalone​VOI​LUT​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.​5.​1.​4.​1.​1.​11.​1

Grayscale Softcopy Presentation State Storage

Grayscale​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​2

Color Softcopy Presentation State Storage

Color​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​3

Pseudo-Color Softcopy Presentation State Storage

Pseudo​Color​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​4

Blending Softcopy Presentation State Storage

Blending​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​5

XA/XRF Grayscale Softcopy Presentation State Storage

XA​XRF​Grayscale​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​6

Grayscale Planar MPR Volumetric Presentation State Storage

Grayscale​Planar​MPR​Volumetric​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​7

Compositing Planar MPR Volumetric Presentation State Storage

Compositing​Planar​MPR​Volumetric​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​8

Advanced Blending Presentation State Storage

Advanced​Blending​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​9

Volume Rendering Volumetric Presentation State Storage

Volume​Rendering​Volumetric​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​10

Segmented Volume Rendering Volumetric Presentation State Storage

Segmented​Volume​Rendering​Volumetric​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​11

Multiple Volume Rendering Volumetric Presentation State Storage

Multiple​Volume​Rendering​Volumetric​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​12

Variable Modality LUT Softcopy Presentation State Storage

Variable​Modality​LUT​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​12.​1

X-Ray Angiographic Image Storage

X​Ray​Angiographic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.12.​1.​1

Enhanced XA Image Storage

Enhanced​XA​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​12.​2

X-Ray Radiofluoroscopic Image Storage

X​Ray​Radiofluoroscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.12.​2.​1

Enhanced XRF Image Storage

Enhanced​XRF​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​12.​3

X-Ray Angiographic Bi-Plane Image Storage (Retired)

XRay​Angiographic​Bi​Plane​Image​Storage

SOP Class

PS3.4 (1998)

1.2.840.10008.​5.​1.​4.​1.​1.​12.​77

(Retired)

SOP Class

(2015c)

1.2.840.10008.​5.​1.​4.​1.​1.13.​1.​1

X-Ray 3D Angiographic Image Storage

X​Ray​3D​Angiographic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.13.​1.​2

X-Ray 3D Craniofacial Image Storage

X​Ray​3D​Craniofacial​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.13.​1.​3

Breast Tomosynthesis Image Storage

Breast​Tomosynthesis​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.1.4.1.1.13.1.4

Breast Projection X-Ray Image Storage - For Presentation

Breast​Projection​X​Ray​Image​​StorageFor​Presentation

SOP Class

PS3.4

1.2.840.10008.​5.1.4.1.1.13.1.5

Breast Projection X-Ray Image Storage - For Processing

Breast​Projection​X​Ray​Image​​StorageFor​Processing

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​14.​1

Intravascular Optical Coherence Tomography Image Storage - For Presentation

Intravascular​Optical​Coherence​Tomography​Image​​StorageFor​Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​14.​2

Intravascular Optical Coherence Tomography Image Storage - For Processing

Intravascular​Optical​Coherence​Tomography​Image​​StorageFor​Processing

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​20

Nuclear Medicine Image Storage

Nuclear​Medicine​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​30

Parametric Map Storage

Parametric​Map​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​40

(Retired)

SOP Class

(2015c)

1.2.840.10008.5.1.4.1.​1.​66

Raw Data Storage

Raw​Data​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​1

Spatial Registration Storage

Spatial​Registration​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​2

Spatial Fiducials Storage

Spatial​Fiducials​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​3

Deformable Spatial Registration Storage

Deformable​Spatial​Registration​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​4

Segmentation Storage

Segmentation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​5

Surface Segmentation Storage

Surface​Segmentation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​6

Tractography Results Storage

Tractography​Results​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​7

Label Map Segmentation Storage

Label​Map​Segmentation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​8

Height Map Segmentation Storage

Height​Map​Segmentation​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​67

Real World Value Mapping Storage

Real​World​Value​Mapping​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​68.​1

Surface Scan Mesh Storage

Surface​Scan​Mesh​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​68.​2

Surface Scan Point Cloud Storage

Surface​Scan​Point​Cloud​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​77.​1

VL Image Storage - Trial (Retired)

VL​Image​Storage​Trial

SOP Class

PS3.4 (1998)

1.2.840.10008.​5.​1.​4.​1.​1.​77.​2

VL Multi-frame Image Storage - Trial (Retired)

VL​Multi​Frame​Image​Storage​Trial

SOP Class

PS3.4 (1998)

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​1

VL Endoscopic Image Storage

VL​Endoscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​1.​1

Video Endoscopic Image Storage

Video​Endoscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​2

VL Microscopic Image Storage

VL​Microscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​2.​1

Video Microscopic Image Storage

Video​Microscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​3

VL Slide-Coordinates Microscopic Image Storage

VL​Slide​Coordinates​Microscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​4

VL Photographic Image Storage

VL​Photographic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​4.​1

Video Photographic Image Storage

Video​Photographic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​1

Ophthalmic Photography 8 Bit Image Storage

Ophthalmic​Photography​8​Bit​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​2

Ophthalmic Photography 16 Bit Image Storage

Ophthalmic​Photography​16​Bit​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​3

Stereometric Relationship Storage

Stereometric​Relationship​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​4

Ophthalmic Tomography Image Storage

Ophthalmic​Tomography​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​5

Wide Field Ophthalmic Photography Stereographic Projection Image Storage

Wide​Field​Ophthalmic​Photography​Stereographic​Projection​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​6

Wide Field Ophthalmic Photography 3D Coordinates Image Storage

Wide​Field​Ophthalmic​Photography​3D​Coordinates​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​7

Ophthalmic Optical Coherence Tomography En Face Image Storage

Ophthalmic​Optical​Coherence​Tomography​En​Face​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​8

Ophthalmic Optical Coherence Tomography B-scan Volume Analysis Storage

Ophthalmic​Optical​Coherence​Tomography​B​scan​Volume​Analysis​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​6

VL Whole Slide Microscopy Image Storage

VL​Whole​Slide​Microscopy​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​7

Dermoscopic Photography Image Storage

Dermoscopic​Photography​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​8

Confocal Microscopy Image Storage

Confocal​Microscopy​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​9

Confocal Microscopy Tiled Pyramidal Image Storage

Confocal​Microscopy​Tiled​Pyramidal​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​1

Lensometry Measurements Storage

Lensometry​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​2

Autorefraction Measurements Storage

Autorefraction​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​3

Keratometry Measurements Storage

Keratometry​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​4

Subjective Refraction Measurements Storage

Subjective​Refraction​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​5

Visual Acuity Measurements Storage

Visual​Acuity​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​6

Spectacle Prescription Report Storage

Spectacle​Prescription​Report​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​7

Ophthalmic Axial Measurements Storage

Ophthalmic​Axial​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​8

Intraocular Lens Calculations Storage

Intraocular​Lens​Calculations​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​79.​1

Macular Grid Thickness and Volume Report Storage

Macular​Grid​Thickness​And​Volume​Report​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​80.​1

Ophthalmic Visual Field Static Perimetry Measurements Storage

Ophthalmic​Visual​Field​Static​Perimetry​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​81.​1

Ophthalmic Thickness Map Storage

Ophthalmic​Thickness​Map​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​82.​1

Corneal Topography Map Storage

Corneal​Topography​Map​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​1

Text SR Storage - Trial (Retired)

Text​SR​Storage​Trial

SOP Class

PS3.4 (2007)

1.2.840.10008.​5.​1.​4.​1.​1.​88.​2

Audio SR Storage - Trial (Retired)

Audio​SR​Storage​Trial

SOP Class

PS3.4 (2007)

1.2.840.10008.​5.​1.​4.​1.​1.​88.​3

Detail SR Storage - Trial (Retired)

Detail​SR​Storage​Trial

SOP Class

PS3.4 (2007)

1.2.840.10008.​5.​1.​4.​1.​1.​88.​4

Comprehensive SR Storage - Trial (Retired)

Comprehensive​SR​Storage​Trial

SOP Class

PS3.4 (2007)

1.2.840.10008.​5.​1.​4.​1.​1.​88.​11

Basic Text SR Storage

Basic​Text​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​22

Enhanced SR Storage

Enhanced​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​33

Comprehensive SR Storage

Comprehensive​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​34

Comprehensive 3D SR Storage

Comprehensive​3D​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​35

Extensible SR Storage

Extensible​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​40

Procedure Log Storage

Procedure​Log​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​50

Mammography CAD SR Storage

Mammography​CAD​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​59

Key Object Selection Document Storage

Key​Object​Selection​Document​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​65

Chest CAD SR Storage

Chest​CAD​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​67

X-Ray Radiation Dose SR Storage

X​Ray​Radiation​Dose​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​68

Radiopharmaceutical Radiation Dose SR Storage

Radiopharmaceutical​Radiation​Dose​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​69

Colon CAD SR Storage

Colon​CAD​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​70

Implantation Plan SR Storage

Implantation​Plan​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​71

Acquisition Context SR Storage

Acquisition​Context​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​72

Simplified Adult Echo SR Storage

Simplified​Adult​Echo​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​73

Patient Radiation Dose SR Storage

Patient​Radiation​Dose​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​74

Planned Imaging Agent Administration SR Storage

Planned​Imaging​Agent​Administration​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​75

Performed Imaging Agent Administration SR Storage

Performed​Imaging​Agent​Administration​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​76

Enhanced X-Ray Radiation Dose SR Storage

Enhanced​XRay​Radiation​Dose​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​77

Waveform Annotation SR Storage

Waveform​Annotation​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​90.​1

Content Assessment Results Storage

Content​Assessment​Results​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​91.​1

Microscopy Bulk Simple Annotations Storage

Microscopy​Bulk​Simple​Annotations​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​1

Encapsulated PDF Storage

Encapsulated​PDF​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​2

Encapsulated CDA Storage

Encapsulated​CDA​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​3

Encapsulated STL Storage

Encapsulated​STL​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​4

Encapsulated OBJ Storage

Encapsulated​OBJ​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​5

Encapsulated MTL Storage

Encapsulated​MTL​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​128

Positron Emission Tomography Image Storage

Positron​Emission​Tomography​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​128.​1

Legacy Converted Enhanced PET Image Storage

Legacy​Converted​Enhanced​PET​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​129

Standalone PET Curve Storage (Retired)

Standalone​PET​Curve​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.​1.​130

Enhanced PET Image Storage

Enhanced​PET​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​131

Basic Structured Display Storage

Basic​Structured​Display​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.1

CT Defined Procedure Protocol Storage

CT​Defined​Procedure​Protocol​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.2

CT Performed Procedure Protocol Storage

CT​Performed​Procedure​Protocol​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.3

Protocol Approval Storage

Protocol​Approval​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.4

Protocol Approval Information Model - FIND

Protocol​Approval​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.5

Protocol Approval Information Model - MOVE

Protocol​Approval​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.6

Protocol Approval Information Model - GET

Protocol​Approval​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.7

XA Defined Procedure Protocol Storage

XA​Defined​Procedure​Protocol​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.8

XA Performed Procedure Protocol Storage

XA​Performed​Procedure​Protocol​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.201.1

Inventory Storage

Inventory​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.201.2

Inventory - FIND

Inventory​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.201.3

Inventory - MOVE

Inventory​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.201.4

Inventory - GET

Inventory​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.201.5

Inventory Creation

Inventory​Creation

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.201.6

Repository Query

Repository​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.201.1.1

Storage Management SOP Instance

Storage​Management​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​1

RT Image Storage

RT​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​2

RT Dose Storage

RT​Dose​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​3

RT Structure Set Storage

RT​Structure​Set​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​4

RT Beams Treatment Record Storage

RT​Beams​Treatment​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​5

RT Plan Storage

RT​Plan​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​6

RT Brachy Treatment Record Storage

RT​Brachy​Treatment​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​7

RT Treatment Summary Record Storage

RT​Treatment​Summary​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​8

RT Ion Plan Storage

RT​Ion​Plan​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​9

RT Ion Beams Treatment Record Storage

RT​Ion​Beams​Treatment​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​10

RT Physician Intent Storage

RT​Physician​Intent​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​11

RT Segment Annotation Storage

RT​Segment​Annotation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​12

RT Radiation Set Storage

RT​Radiation​Set​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​13

C-Arm Photon-Electron Radiation Storage

C​Arm​Photon​Electron​Radiation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​14

Tomotherapeutic Radiation Storage

Tomotherapeutic​Radiation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​15

Robotic-Arm Radiation Storage

Robotic​Arm​Radiation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​16

RT Radiation Record Set Storage

RT​Radiation​Record​Set​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​17

RT Radiation Salvage Record Storage

RT​Radiation​Salvage​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​18

Tomotherapeutic Radiation Record Storage

Tomotherapeutic​Radiation​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​19

C-Arm Photon-Electron Radiation Record Storage

C​Arm​Photon​Electron​Radiation​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​20

Robotic Radiation Record Storage

Robotic​Radiation​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​21

RT Radiation Set Delivery Instruction Storage

RT​Radiation​Set​Delivery​Instruction​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​22

RT Treatment Preparation Storage

RT​Treatment​Preparation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​23

Enhanced RT Image Storage

Enhanced​RT​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​24

Enhanced Continuous RT Image Storage

Enhanced​Continuous​RT​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​25

RT Patient Position Acquisition Instruction Storage

RT​Patient​Position​Acquisition​Instruction​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​501.​1

DICOS CT Image Storage

DICOS​CT​Image​Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.501.​2.​1

DICOS Digital X-Ray Image Storage - For Presentation

DICOS​Digital​X​Ray​Image​​StorageFor​Presentation

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.501.​2.​2

DICOS Digital X-Ray Image Storage - For Processing

DICOS​Digital​X​Ray​Image​​StorageFor​Processing

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​3

DICOS Threat Detection Report Storage

DICOS​Threat​Detection​Report​Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​4

DICOS 2D AIT Storage

DICOS​2D​AIT​Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​5

DICOS 3D AIT Storage

DICOS​3D​AIT​Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​6

DICOS Quadrupole Resonance (QR) Storage

DICOS​Quadrupole​Resonance​Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​601.​1

Eddy Current Image Storage

Eddy​Current​Image​Storage

SOP Class

DICONDE ASTM E2934

1.2.840.10008.​5.​1.​4.​1.​1.​601.​2

Eddy Current Multi-frame Image Storage

Eddy​Current​Multi​Frame​Image​Storage

SOP Class

DICONDE ASTM E2934

1.2.840.10008.​5.​1.​4.​1.​1.​601.​3

Thermography Image Storage

Thermography​Image​Storage

SOP Class

DICONDE ASTM E3440

1.2.840.10008.​5.​1.​4.​1.​1.​601.​4

Thermography Multi-frame Image Storage

Thermography​Multi​Frame​Image​Storage

SOP Class

DICONDE ASTM E3440

1.2.840.10008.5.1.4.1.2.​1.​1

Patient Root Query/Retrieve Information Model - FIND

Patient​Root​Query​Retrieve​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​1.​2

Patient Root Query/Retrieve Information Model - MOVE

Patient​Root​Query​Retrieve​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​1.​3

Patient Root Query/Retrieve Information Model - GET

Patient​Root​Query​Retrieve​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​2.​1

Study Root Query/Retrieve Information Model - FIND

Study​Root​Query​Retrieve​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​2.​2

Study Root Query/Retrieve Information Model - MOVE

Study​Root​Query​Retrieve​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​2.​3

Study Root Query/Retrieve Information Model - GET

Study​Root​Query​Retrieve​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​3.​1

Patient/Study Only Query/Retrieve Information Model - FIND (Retired)

Patient​​Study​Only​Query​Retrieve​Information​Model​Find

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.2.​3.​2

Patient/Study Only Query/Retrieve Information Model - MOVE (Retired)

Patient​Study​Only​Query​Retrieve​Information​Model​Move

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.2.​3.​3

Patient/Study Only Query/Retrieve Information Model - GET (Retired)

Patient​Study​Only​Query​Retrieve​Information​Model​Get

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.2.​4.​2

Composite Instance Root Retrieve - MOVE

Composite​Instance​Root​Retrieve​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​4.​3

Composite Instance Root Retrieve - GET

Composite​Instance​Root​Retrieve​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​5.​3

Composite Instance Retrieve Without Bulk Data - GET

Composite​Instance​Retrieve​Without​Bulk​Data​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.20.1

Defined Procedure Protocol Information Model - FIND

Defined​Procedure​Protocol​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.20.2

Defined Procedure Protocol Information Model - MOVE

Defined​Procedure​Protocol​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.20.3

Defined Procedure Protocol Information Model - GET

Defined​Procedure​Protocol​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​31

Modality Worklist Information Model - FIND

Modality​Worklist​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​32

General Purpose Worklist Management Meta SOP Class (Retired)

General​Purpose​Worklist​Management​Meta

Meta SOP Class

PS3.4 (2011)

1.2.840.10008.5.1.4.​32.​1

General Purpose Worklist Information Model - FIND (Retired)

General​Purpose​Worklist​Information​ModelFind

SOP Class

PS3.4 (2011)

1.2.840.10008.5.1.4.​32.​2

General Purpose Scheduled Procedure Step SOP Class (Retired)

General​Purpose​Scheduled​Procedure​Step

SOP Class

PS3.4 (2011)

1.2.840.10008.5.1.4.​32.​3

General Purpose Performed Procedure Step SOP Class (Retired)

General​Purpose​Performed​Procedure​Step

SOP Class

PS3.4 (2011)

1.2.840.10008.5.1.​4.​33

Instance Availability Notification SOP Class

Instance​Availability​Notification

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​1

RT Beams Delivery Instruction Storage - Trial (Retired)

RT​Beams​Delivery​Instruction​Storage​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.​34.​2

RT Conventional Machine Verification - Trial (Retired)

RT​Conventional​Machine​Verification​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.​34.​3

RT Ion Machine Verification - Trial (Retired)

RT​Ion​Machine​Verification​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.​34.​4

Unified Worklist and Procedure Step Service Class - Trial (Retired)

Unified​Worklist​And​Procedure​Step​Trial

Service Class

PS3.4 (2009)

1.2.840.10008.5.1.4.34.​4.​1

Unified Procedure Step - Push SOP Class - Trial (Retired)

Unified​Procedure​Step​Push​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.34.​4.​2

Unified Procedure Step - Watch SOP Class - Trial (Retired)

Unified​Procedure​Step​Watch​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.34.​4.​3

Unified Procedure Step - Pull SOP Class - Trial (Retired)

Unified​Procedure​Step​Pull​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.34.​4.​4

Unified Procedure Step - Event SOP Class - Trial (Retired)

Unified​Procedure​Step​Event​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.​34.​5

UPS Global Subscription SOP Instance

UPS​Global​Subscription​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.4.​34.​5.​1

UPS Filtered Global Subscription SOP Instance

UPS​Filtered​Global​Subscription​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.4.​34.​6

Unified Worklist and Procedure Step Service Class

Unified​Worklist​And​Procedure​Step

Service Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​1

Unified Procedure Step - Push SOP Class

Unified​Procedure​Step​Push

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​2

Unified Procedure Step - Watch SOP Class

Unified​Procedure​Step​Watch

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​3

Unified Procedure Step - Pull SOP Class

Unified​Procedure​Step​Pull

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​4

Unified Procedure Step - Event SOP Class

Unified​Procedure​Step​Event

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​5

Unified Procedure Step - Query SOP Class

Unified​Procedure​Step​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​7

RT Beams Delivery Instruction Storage

RT​Beams​Delivery​Instruction​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​8

RT Conventional Machine Verification

RT​Conventional​Machine​Verification

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​9

RT Ion Machine Verification

RT​Ion​Machine​Verification

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​10

RT Brachy Application Setup Delivery Instruction Storage

RT​Brachy​Application​Setup​Delivery​Instruction​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​37.​1

General Relevant Patient Information Query

General​Relevant​Patient​Information​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​37.​2

Breast Imaging Relevant Patient Information Query

Breast​Imaging​Relevant​Patient​Information​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​37.​3

Cardiac Relevant Patient Information Query

Cardiac​Relevant​Patient​Information​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​1

Hanging Protocol Storage

Hanging​Protocol​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​2

Hanging Protocol Information Model - FIND

Hanging​Protocol​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​3

Hanging Protocol Information Model - MOVE

Hanging​Protocol​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​4

Hanging Protocol Information Model - GET

Hanging​Protocol​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​1

Color Palette Storage

Color​Palette​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​2

Color Palette Query/Retrieve Information Model - FIND

Color​Palette​Query​Retrieve​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​3

Color Palette Query/Retrieve Information Model - MOVE

Color​Palette​Query​Retrieve​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​4

Color Palette Query/Retrieve Information Model - GET

Color​Palette​Query​Retrieve​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​41

Product Characteristics Query SOP Class

Product​Characteristics​Query

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​42

Substance Approval Query SOP Class

Substance​Approval​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​1

Generic Implant Template Storage

Generic​Implant​Template​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​2

Generic Implant Template Information Model - FIND

Generic​Implant​Template​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​3

Generic Implant Template Information Model - MOVE

Generic​Implant​Template​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​4

Generic Implant Template Information Model - GET

Generic​Implant​Template​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​1

Implant Assembly Template Storage

Implant​Assembly​Template​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​2

Implant Assembly Template Information Model - FIND

Implant​Assembly​Template​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​3

Implant Assembly Template Information Model - MOVE

Implant​Assembly​Template​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​4

Implant Assembly Template Information Model - GET

Implant​Assembly​Template​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​1

Implant Template Group Storage

Implant​Template​Group​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​2

Implant Template Group Information Model - FIND

Implant​Template​Group​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​3

Implant Template Group Information Model - MOVE

Implant​Template​Group​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​4

Implant Template Group Information Model - GET

Implant​Template​Group​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.7.​1.​1

Native DICOM Model

Native​DICOM​Model

Application Hosting Model

PS3.19

1.2.840.10008.7.​1.​2

Abstract Multi-Dimensional Image Model

Abstract​Multi​Dimensional​Image​Model

Application Hosting Model

PS3.19

1.2.840.10008.8.​1.​1

DICOM Content Mapping Resource

DICOM​Content​Mapping​Resource

Mapping Resource

PS3.16

1.2.840.10008.10.1

Video Endoscopic Image Real-Time Communication

Video​Endoscopic​Image​Real​Time​Communication

SOP Class

PS3.22

1.2.840.10008.10.2

Video Photographic Image Real-Time Communication

Video​Photographic​Image​Real​Time​Communication

SOP Class

PS3.22

1.2.840.10008.10.3

Audio Waveform Real-Time Communication

Audio​Waveform​Real​Time​Communication

SOP Class

PS3.22

1.2.840.10008.10.4

Rendition Selection Document Real-Time Communication

Rendition​Selection​Document​Real​Time​Communication

SOP Class

PS3.22

1.2.840.10008.15.0.​3.​1

dicom​Device​Name

dicom​Device​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​2

dicom​Description

dicom​Description

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​3

dicom​Manufacturer

dicom​Manufacturer

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​4

dicom​Manufacturer​Model​Name

dicom​Manufacturer​Model​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​5

dicom​Software​Version

dicom​Software​Version

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​6

dicom​Vendor​Data

dicom​Vendor​Data

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​7

dicom​AE​Title

dicom​AE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​8

dicom​Network​Connection​Reference

dicom​Network​Connection​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​9

dicom​Application​Cluster

dicom​Application​Cluster

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​10

dicom​Association​Initiator

dicom​Association​Initiator

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​11

dicom​Association​Acceptor

dicom​Association​Acceptor

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​12

dicom​Hostname

dicom​Hostname

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​13

dicom​Port

dicom​Port

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​14

dicom​SOP​Class

dicom​SOP​Class

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​15

dicom​Transfer​Role

dicom​Transfer​Role

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​16

dicom​Transfer​Syntax

dicom​Transfer​Syntax

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​17

dicom​Primary​Device​Type

dicom​Primary​Device​Type

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​18

dicom​Related​Device​Reference

dicom​Related​Device​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​19

dicom​Preferred​Called​AE​Title

dicom​Preferred​Called​AE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​20

dicom​TLS​Cyphersuite

dicom​TLS​Cyphersuite

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​21

dicom​Authorized​Node​Certificate​Reference

dicom​Authorized​Node​Certificate​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​22

dicom​This​Node​Certificate​Reference

dicom​This​Node​Certificate​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​23

dicom​Installed

dicom​Installed

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​24

dicom​Station​Name

dicom​Station​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​25

dicom​Device​Serial​Number

dicom​Device​Serial​Number

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​26

dicom​Institution​Name

dicom​Institution​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​27

dicom​Institution​Address

dicom​Institution​Address

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​28

dicom​Institution​Department​Name

dicom​Institution​Department​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​29

dicom​Issuer​Of​Patient​ID

dicom​Issuer​Of​Patient​ID

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​30

dicom​Preferred​Calling​AE​Title

dicom​Preferred​Calling​AE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​31

dicom​Supported​Character​Set

dicom​Supported​Character​Set

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​1

dicom​Configuration​Root

dicom​Configuration​Root

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​2

dicom​Devices​Root

dicom​Devices​Root

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​3

dicom​Unique​AE​Titles​Registry​Root

dicom​Unique​AE​Titles​Registry​Root

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​4

dicom​Device

dicom​Device

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​5

dicom​Network​AE

dicom​Network​AE

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​6

dicom​Network​Connection

dicom​Network​Connection

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​7

dicom​Unique​AE​Title

dicom​Unique​AE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​8

dicom​Transfer​Capability

dicom​Transfer​Capability

LDAP OID

PS3.15

1.2.840.10008.15.​1.​1

Universal Coordinated Time

UTC

Synchronization Frame of Reference

PS3.3


Table A-2 lists the UID values that are registered for Frames of Reference.

Table A-2. Well-known Frames of Reference

UID Value

UID Name

UID ​Keyword

Normative Reference

1.2.840.10008.1.4.​1.​1

Talairach Brain Atlas Frame of Reference

Talairach​Brain​Atlas

Talairach J. and Tournoux P. Co-Planar stereotactic atlas of the human brain. Stuttgart: Georg Thieme Verlag, 1988.

1.2.840.10008.1.4.​1.​2

SPM2 T1 Frame of Reference

SPM2​T1

http://​github.com/​spm/​spm2/​blob/​master/templates/T1.mnc

1.2.840.10008.1.4.​1.​3

SPM2 T2 Frame of Reference

SPM2​T2

http://​github.com/​spm/​spm2/​blob/​master/templates/T2.mnc

1.2.840.10008.1.4.​1.​4

SPM2 PD Frame of Reference

SPM2​PD

http://​github.com/​spm/​spm2/​blob/​master/templates/PD.mnc

1.2.840.10008.1.4.​1.​5

SPM2 EPI Frame of Reference

SPM2​EPI

http://​github.com/​spm/​spm2/​blob/​master/templates/EPI.mnc

1.2.840.10008.1.4.​1.​6

SPM2 FIL T1 Frame of Reference

SPM2​FILT1

http://​github.com/​spm/​spm2/​blob/​master/templates/filT1.mnc

1.2.840.10008.1.4.​1.​7

SPM2 PET Frame of Reference

SPM2​PET

http://​github.com/​spm/​spm2/​blob/​master/templates/PET.mnc

1.2.840.10008.1.4.​1.​8

SPM2 TRANSM Frame of Reference

SPM2​TRANSM

http://​github.com/​spm/​spm2/​blob/​master/templates/Transm.mnc

1.2.840.10008.1.4.​1.​9

SPM2 SPECT Frame of Reference

SPM2​SPECT

http://​github.com/​spm/​spm2/​blob/​master/templates/SPECT.mnc

1.2.840.10008.1.4.​1.​10

SPM2 GRAY Frame of Reference

SPM2​GRAY

http://​github.com/​spm/​spm2/​blob/​master/apriori/gray.mnc

1.2.840.10008.1.4.​1.​11

SPM2 WHITE Frame of Reference

SPM2​WHITE

http://​github.com/​spm/​spm2/​blob/​master/apriori/white.mnc

1.2.840.10008.1.4.​1.​12

SPM2 CSF Frame of Reference

SPM2​CSF

http://​github.com/​spm/​spm2/​blob/​master/apriori/csf.mnc

1.2.840.10008.1.4.​1.​13

SPM2 BRAINMASK Frame of Reference

SPM2​BRAIN​MASK

http://​github.com/​spm/​spm2/​blob/​master/apriori/brainmask.mnc

1.2.840.10008.1.4.​1.​14

SPM2 AVG305T1 Frame of Reference

SPM2AVG305T1

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg305T1.mnc

1.2.840.10008.1.4.​1.​15

SPM2 AVG152T1 Frame of Reference

SPM2​AVG152T1

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152T1.mnc

1.2.840.10008.1.4.​1.​16

SPM2 AVG152T2 Frame of Reference

SPM2​AVG152T2

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152T2.mnc

1.2.840.10008.1.4.​1.​17

SPM2 AVG152PD Frame of Reference

SPM2​AVG152PD

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152PD.mnc

1.2.840.10008.1.4.​1.​18

SPM2 SINGLESUBJT1 Frame of Reference

SPM2​SINGLESUBJT1

http://​github.com/​spm/​spm2/​blob/​master/canonical/single_subj_T1.mnc

1.2.840.10008.1.4.​2.​1

ICBM 452 T1 Frame of Reference

ICBM​452T1

ICBM452 T1 Atlas http://resource.loni.usc.edu/​atlasfiles/​ICBM_452_T1_Atlas_Affine_Transformations.zip

1.2.840.10008.1.4.​2.​2

ICBM Single Subject MRI Frame of Reference

ICBM​Single​Subject​MRI

ICBM Single Subject MRI Anatomical Template http://resource.loni.usc.edu/​atlasfiles/​ICBM_Single_Subject_MRI_Anatomical_Template.zip

1.2.840.10008.1.4.3.1

IEC 61217 Fixed Coordinate System Frame of Reference

IEC​61217​Fixed​Coordinate​System

Fixed coordinate system ("f") of [IEC 61217] and Section C.36.12.2.1 “IEC 61217 Fixed Reference System Frame of Reference” in PS3.3

1.2.840.10008.1.4.3.2

Standard Robotic-Arm Coordinate System Frame of Reference

Standard​Robotic​Arm​Coordinate​System

See Section C.36.12.2.2 “Standard Robotic-Arm Coordinate System Frame of Reference” in PS3.3 .

1.2.840.10008.1.4.3.3

IEC 61217 Table Top Coordinate System Frame of Reference

IEC​61217​Table​Top​Coordinate​System

Table top coordinate system ("t") of [IEC 61217].

1.2.840.10008.1.4.4.1

SRI24 Frame of Reference

SRI24

http://​www.nitrc.org/projects/​sri24/

1.2.840.10008.1.4.​5.1

Colin27 Frame of Reference

Colin27

http://​www.bic.mni.mcgill.ca/​ServicesAtlases/​Colin27

1.2.840.10008.1.4.​6.1

LPBA40/AIR Frame of Reference

LPBA40AIR

http://​resource.loni.usc.edu/​atlasfiles/​LPBA40_AIR_Atlas_NIFTI_format.zip

1.2.840.10008.1.4.​6.2

LPBA40/FLIRT Frame of Reference

LPBA40FLIRT

http://​resource.loni.usc.edu/​atlasfiles/​LPBA40_FLIRT_Atlas_NIFTI_format.zip

1.2.840.10008.1.4.​6.3

LPBA40/SPM5 Frame of Reference

LPBA40SPM5

http://​resource.loni.usc.edu/​atlasfiles/​LPBA40_SPM5_atlas_NIFTI_format.zip


SPM2 (Statistical Parametric Mapping) templates are available at http://github.com/spm/spm2/, and they are described at https://github.com/spm/spm2/blob/master/spm_templates.man.

ICBM templates are available at http://resource.loni.usc.edu/resources/atlases-downloads/ and http://bmap.ucla.edu/portfolio/atlases.

Table A-3 lists the Context Groups and their UID values. For retired Context Groups, the edition of the Standard in parentheses is the edition in which the item last appeared before it was retired.

Table A-3. Context Group UID Values

Context Group UID

Context Group Identifier

Context Group Name

Comment

1.2.840.10008.6.​1.​1

CID 2

Anatomic Modifier

1.2.840.10008.6.​1.​2

CID 4

Anatomic Region

1.2.840.10008.6.​1.​3

CID 5

Transducer Approach

1.2.840.10008.6.​1.​4

CID 6

Transducer Orientation

1.2.840.10008.6.​1.​5

CID 7

Ultrasound Beam Path

1.2.840.10008.6.​1.​6

CID 8

Angiographic Interventional Device

1.2.840.10008.6.​1.​7

CID 9

Image Guided Therapeutic Procedure

1.2.840.10008.6.​1.​8

CID 10

Interventional Drug

1.2.840.10008.6.​1.​9

CID 11

Administration Route

1.2.840.10008.6.​1.​10

CID 12

Imaging Contrast Agent

1.2.840.10008.6.​1.​11

CID 13

Imaging Contrast Agent Ingredient

1.2.840.10008.6.​1.​12

CID 18

Radiopharmaceutical Isotope

1.2.840.10008.6.​1.​13

CID 19

Patient Orientation

1.2.840.10008.6.​1.​14

CID 20

Patient Orientation Modifier

1.2.840.10008.6.​1.​15

CID 21

Patient Equipment Relationship

1.2.840.10008.6.​1.​16

CID 23

Cranio-Caudad Angulation

1.2.840.10008.6.​1.​17

CID 25

Radiopharmaceutical

1.2.840.10008.6.​1.​18

CID 26

Nuclear Medicine Projection

1.2.840.10008.6.​1.​19

CID 29

Acquisition Modality

1.2.840.10008.6.​1.​20

CID 30

DICOM Device

1.2.840.10008.6.​1.​21

CID 31

Abstract Prior

1.2.840.10008.6.​1.​22

CID 42

Numeric Value Qualifier

1.2.840.10008.6.​1.​23

CID 82

Measurement Unit

1.2.840.10008.6.​1.​24

CID 83

Real World Value Mapping Unit

1.2.840.10008.6.​1.​25

CID 220

Significance Level

1.2.840.10008.6.​1.​26

CID 221

Measurement Range Concept

1.2.840.10008.6.​1.​27

CID 222

Normality

1.2.840.10008.6.​1.​28

CID 223

Normal Range Value

1.2.840.10008.6.​1.​29

CID 224

Selection Method

1.2.840.10008.6.​1.​30

CID 225

Measurement Uncertainty Concept

1.2.840.10008.6.​1.​31

CID 226

Population Statistical Descriptor

1.2.840.10008.6.​1.​32

CID 227

Sample Statistical Descriptor

1.2.840.10008.6.​1.​33

CID 228

Equation or Table

1.2.840.10008.6.​1.​34

CID 230

Yes-No

1.2.840.10008.6.​1.​35

CID 240

Present-Absent

1.2.840.10008.6.​1.​36

CID 242

Normal-Abnormal

1.2.840.10008.6.​1.​37

CID 244

Laterality

1.2.840.10008.6.​1.​38

CID 250

Positive-Negative

1.2.840.10008.6.​1.​39

CID 251

Complication Severity

1.2.840.10008.6.​1.​40

CID 270

Observer Type

1.2.840.10008.6.​1.​41

CID 271

Observation Subject Class

1.2.840.10008.6.​1.​42

CID 3000

Audio Channel Source

1.2.840.10008.6.​1.​43

CID 3001

ECG Lead

1.2.840.10008.6.​1.​44

CID 3003

Hemodynamic Waveform Source

1.2.840.10008.6.​1.​45

CID 3010

Cardiovascular Anatomic Structure

1.2.840.10008.6.​1.​46

CID 3011

Electrophysiology Anatomic Location

1.2.840.10008.6.​1.​47

CID 3014

Coronary Artery Segment

1.2.840.10008.6.​1.​48

CID 3015

Coronary Artery

1.2.840.10008.6.​1.​49

CID 3019

Cardiovascular Anatomic Structure Modifier

1.2.840.10008.6.​1.​50

CID 3082

Cardiology Measurement Unit (Retired)

RET (2011)

1.2.840.10008.6.​1.​51

CID 3090

Time Synchronization Channel Type

1.2.840.10008.6.​1.​52

CID 3101

Cardiac Procedural State Value

1.2.840.10008.6.​1.​53

CID 3240

Electrophysiology Measurement Function/Technique

1.2.840.10008.6.​1.​54

CID 3241

Hemodynamic Measurement Technique

1.2.840.10008.6.​1.​55

CID 3250

Catheterization Procedure Phase

1.2.840.10008.6.​1.​56

CID 3254

Electrophysiology Procedure Phase

1.2.840.10008.6.​1.​57

CID 3261

Stress Protocol

1.2.840.10008.6.​1.​58

CID 3262

ECG Patient State Value

1.2.840.10008.6.​1.​59

CID 3263

Electrode Placement Value

1.2.840.10008.6.​1.​60

CID 3264

XYZ Electrode Placement Values (Retired)

RET (2013)

1.2.840.10008.6.​1.​61

CID 3271

Hemodynamic Physiological Challenge

1.2.840.10008.6.​1.​62

CID 3335

ECG Annotation

1.2.840.10008.6.​1.​63

CID 3337

Hemodynamic Annotation

1.2.840.10008.6.​1.​64

CID 3339

Electrophysiology Annotation

1.2.840.10008.6.​1.​65

CID 3400

Procedure Log Title

1.2.840.10008.6.​1.​66

CID 3401

Log Note Type

1.2.840.10008.6.​1.​67

CID 3402

Patient Status and Event

1.2.840.10008.6.​1.​68

CID 3403

Percutaneous Entry

1.2.840.10008.6.​1.​69

CID 3404

Staff Action

1.2.840.10008.6.​1.​70

CID 3405

Procedure Action Value

1.2.840.10008.6.​1.​71

CID 3406

Non-coronary Transcatheter Intervention

1.2.840.10008.6.​1.​72

CID 3407

Object Reference Purpose

1.2.840.10008.6.​1.​73

CID 3408

Consumable Action

1.2.840.10008.6.​1.​74

CID 3409

Drug/Contrast Administration

1.2.840.10008.6.​1.​75

CID 3410

Drug/Contrast Numeric Parameter

1.2.840.10008.6.​1.​76

CID 3411

Intracoronary Device

1.2.840.10008.6.​1.​77

CID 3412

Intervention Action/Status

1.2.840.10008.6.​1.​78

CID 3413

Adverse Outcome

1.2.840.10008.6.​1.​79

CID 3414

Procedure Urgency

1.2.840.10008.6.​1.​80

CID 3415

Cardiac Rhythm

1.2.840.10008.6.​1.​81

CID 3416

Respiration Rhythm

1.2.840.10008.6.​1.​82

CID 3418

Lesion Risk

1.2.840.10008.6.​1.​83

CID 3419

Finding Title

1.2.840.10008.6.​1.​84

CID 3421

Procedure Action

1.2.840.10008.6.​1.​85

CID 3422

Device Use Action

1.2.840.10008.6.​1.​86

CID 3423

Numeric Device Characteristic

1.2.840.10008.6.​1.​87

CID 3425

Intervention Parameter

1.2.840.10008.6.​1.​88

CID 3426

Consumables Parameter

1.2.840.10008.6.​1.​89

CID 3427

Equipment Event

1.2.840.10008.6.​1.​90

CID 3428

Cardiovascular Imaging Procedure

1.2.840.10008.6.​1.​91

CID 3429

Catheterization Device

1.2.840.10008.6.​1.​92

CID 3430

DateTime Qualifier

1.2.840.10008.6.​1.​93

CID 3440

Peripheral Pulse Location

1.2.840.10008.6.​1.​94

CID 3441

Patient Assessment

1.2.840.10008.6.​1.​95

CID 3442

Peripheral Pulse Method

1.2.840.10008.6.​1.​96

CID 3446

Skin Condition

1.2.840.10008.6.​1.​97

CID 3448

Airway Assessment

1.2.840.10008.6.​1.​98

CID 3451

Calibration Object

1.2.840.10008.6.​1.​99

CID 3452

Calibration Method

1.2.840.10008.6.​1.​100

CID 3453

Cardiac Volume Method

1.2.840.10008.6.​1.​101

CID 3455

Index Method

1.2.840.10008.6.​1.​102

CID 3456

Sub-segment Method

1.2.840.10008.6.​1.​103

CID 3458

Contour Realignment

1.2.840.10008.6.​1.​104

CID 3460

Circumferential Extent

1.2.840.10008.6.​1.​105

CID 3461

Regional Extent

1.2.840.10008.6.​1.​106

CID 3462

Chamber Identification

1.2.840.10008.6.​1.​107

CID 3465

QA Reference Method

1.2.840.10008.6.​1.​108

CID 3466

Plane Identification

1.2.840.10008.6.​1.​109

CID 3467

Ejection Fraction

1.2.840.10008.6.​1.​110

CID 3468

ED Volume

1.2.840.10008.6.​1.​111

CID 3469

ES Volume

1.2.840.10008.6.​1.​112

CID 3470

Vessel Lumen Cross-sectional Area Calculation Method

1.2.840.10008.6.​1.​113

CID 3471

Estimated Volume

1.2.840.10008.6.​1.​114

CID 3472

Cardiac Contraction Phase

1.2.840.10008.6.​1.​115

CID 3480

IVUS Procedure Phase

1.2.840.10008.6.​1.​116

CID 3481

IVUS Distance Measurement

1.2.840.10008.6.​1.​117

CID 3482

IVUS Area Measurement

1.2.840.10008.6.​1.​118

CID 3483

IVUS Longitudinal Measurement

1.2.840.10008.6.​1.​119

CID 3484

IVUS Index/Ratio

1.2.840.10008.6.​1.​120

CID 3485

IVUS Volume Measurement

1.2.840.10008.6.​1.​121

CID 3486

Vascular Measurement Site

1.2.840.10008.6.​1.​122

CID 3487

Intravascular Volumetric Region

1.2.840.10008.6.​1.​123

CID 3488

Min/Max/Mean

1.2.840.10008.6.​1.​124

CID 3489

Calcium Distribution

1.2.840.10008.6.​1.​125

CID 3491

IVUS Lesion Morphology

1.2.840.10008.6.​1.​126

CID 3492

Vascular Dissection Classification

1.2.840.10008.6.​1.​127

CID 3493

IVUS Relative Stenosis Severity

1.2.840.10008.6.​1.​128

CID 3494

IVUS Non Morphological Finding

1.2.840.10008.6.​1.​129

CID 3495

IVUS Plaque Composition

1.2.840.10008.6.​1.​130

CID 3496

IVUS Fiducial Point

1.2.840.10008.6.​1.​131

CID 3497

IVUS Arterial Morphology

1.2.840.10008.6.​1.​132

CID 3500

Pressure Unit

1.2.840.10008.6.​1.​133

CID 3502

Hemodynamic Resistance Unit

1.2.840.10008.6.​1.​134

CID 3503

Indexed Hemodynamic Resistance Unit

1.2.840.10008.6.​1.​135

CID 3510

Catheter Size Unit

1.2.840.10008.6.​1.​136

CID 3515

Specimen Collection

1.2.840.10008.6.​1.​137

CID 3520

Blood Source Type

1.2.840.10008.6.​1.​138

CID 3524

Blood Gas Pressure

1.2.840.10008.6.​1.​139

CID 3525

Blood Gas Content

1.2.840.10008.6.​1.​140

CID 3526

Blood Gas Saturation

1.2.840.10008.6.​1.​141

CID 3527

Blood Base Excess

1.2.840.10008.6.​1.​142

CID 3528

Blood pH

1.2.840.10008.6.​1.​143

CID 3529

Arterial / Venous Content

1.2.840.10008.6.​1.​144

CID 3530

Oxygen Administration Action

1.2.840.10008.6.​1.​145

CID 3531

Oxygen Administration

1.2.840.10008.6.​1.​146

CID 3550

Circulatory Support Action

1.2.840.10008.6.​1.​147

CID 3551

Ventilation Action

1.2.840.10008.6.​1.​148

CID 3552

Pacing Action

1.2.840.10008.6.​1.​149

CID 3553

Circulatory Support

1.2.840.10008.6.​1.​150

CID 3554

Ventilation

1.2.840.10008.6.​1.​151

CID 3555

Pacing

1.2.840.10008.6.​1.​152

CID 3560

Blood Pressure Method

1.2.840.10008.6.​1.​153

CID 3600

Relative Time

1.2.840.10008.6.​1.​154

CID 3602

Hemodynamic Patient State

1.2.840.10008.6.​1.​155

CID 3604

Arterial Lesion Location

1.2.840.10008.6.​1.​156

CID 3606

Arterial Source Location

1.2.840.10008.6.​1.​157

CID 3607

Venous Source Location

1.2.840.10008.6.​1.​158

CID 3608

Atrial Source Location

1.2.840.10008.6.​1.​159

CID 3609

Ventricular Source Location

1.2.840.10008.6.​1.​160

CID 3610

Gradient Source Location

1.2.840.10008.6.​1.​161

CID 3611

Pressure Measurement

1.2.840.10008.6.​1.​162

CID 3612

Blood Velocity Measurement

1.2.840.10008.6.​1.​163

CID 3613

Hemodynamic Time Measurement

1.2.840.10008.6.​1.​164

CID 3614

Non-mitral Valve Area

1.2.840.10008.6.​1.​165

CID 3615

Valve Area

1.2.840.10008.6.​1.​166

CID 3616

Hemodynamic Period Measurement

1.2.840.10008.6.​1.​167

CID 3617

Valve Flow

1.2.840.10008.6.​1.​168

CID 3618

Hemodynamic Flow

1.2.840.10008.6.​1.​169

CID 3619

Hemodynamic Resistance Measurement

1.2.840.10008.6.​1.​170

CID 3620

Hemodynamic Ratio

1.2.840.10008.6.​1.​171

CID 3621

Fractional Flow Reserve

1.2.840.10008.6.​1.​172

CID 3627

Measurement Type

1.2.840.10008.6.​1.​173

CID 3628

Cardiac Output Method

1.2.840.10008.6.​1.​174

CID 3629

Procedure Intent

1.2.840.10008.6.​1.​175

CID 3630

Cardiovascular Anatomic Location

1.2.840.10008.6.​1.​176

CID 3640

Hypertension

1.2.840.10008.6.​1.​177

CID 3641

Hemodynamic Assessment

1.2.840.10008.6.​1.​178

CID 3642

Degree Finding

1.2.840.10008.6.​1.​179

CID 3651

Hemodynamic Measurement Phase

1.2.840.10008.6.​1.​180

CID 3663

Body Surface Area Equation

1.2.840.10008.6.​1.​181

CID 3664

Oxygen Consumption Equation/Table

1.2.840.10008.6.​1.​182

CID 3666

P50 Equation

1.2.840.10008.6.​1.​183

CID 3667

Framingham Score

1.2.840.10008.6.​1.​184

CID 3668

Framingham Table

1.2.840.10008.6.​1.​185

CID 3670

ECG Procedure Type

1.2.840.10008.6.​1.​186

CID 3671

Reason for ECG Study

1.2.840.10008.6.​1.​187

CID 3672

Pacemaker

1.2.840.10008.6.​1.​188

CID 3673

Diagnosis (Retired)

RET (2013)

1.2.840.10008.6.​1.​189

CID 3675

Other Filters (Retired)

RET (2013)

1.2.840.10008.6.​1.​190

CID 3676

Lead Measurement Technique

1.2.840.10008.6.​1.​191

CID 3677

Summary Codes ECG

1.2.840.10008.6.​1.​192

CID 3678

QT Correction Algorithm

1.2.840.10008.6.​1.​193

CID 3679

ECG Morphology Description (Retired)

RET (2013)

1.2.840.10008.6.​1.​194

CID 3680

ECG Lead Noise Description

1.2.840.10008.6.​1.​195

CID 3681

ECG Lead Noise Modifier (Retired)

1.2.840.10008.6.​1.​196

CID 3682

Probability (Retired)

RET (2013)

1.2.840.10008.6.​1.​197

CID 3683

Modifier (Retired)

RET (2013)

1.2.840.10008.6.​1.​198

CID 3684

Trend (Retired)

RET (2013)

1.2.840.10008.6.​1.​199

CID 3685

Conjunctive Term (Retired)

RET (2013)

1.2.840.10008.6.​1.​200

CID 3686

ECG Interpretive Statement (Retired)

RET (2013)

1.2.840.10008.6.​1.​201

CID 3687

Electrophysiology Waveform Duration

1.2.840.10008.6.​1.​202

CID 3688

Electrophysiology Waveform Voltage

1.2.840.10008.6.​1.​203

CID 3700

Cath Diagnosis

1.2.840.10008.6.​1.​204

CID 3701

Cardiac Valve/Tract

1.2.840.10008.6.​1.​205

CID 3703

Wall Motion

1.2.840.10008.6.​1.​206

CID 3704

Myocardium Wall Morphology Finding

1.2.840.10008.6.​1.​207

CID 3705

Chamber Size

1.2.840.10008.6.​1.​208

CID 3706

Overall Contractility

1.2.840.10008.6.​1.​209

CID 3707

VSD Description

1.2.840.10008.6.​1.​210

CID 3709

Aortic Root Description

1.2.840.10008.6.​1.​211

CID 3710

Coronary Dominance

1.2.840.10008.6.​1.​212

CID 3711

Valvular Abnormality

1.2.840.10008.6.​1.​213

CID 3712

Vessel Descriptor

1.2.840.10008.6.​1.​214

CID 3713

TIMI Flow Characteristic

1.2.840.10008.6.​1.​215

CID 3714

Thrombus

1.2.840.10008.6.​1.​216

CID 3715

Lesion Margin

1.2.840.10008.6.​1.​217

CID 3716

Severity

1.2.840.10008.6.​1.​218

CID 3717

Left Ventricle Myocardial Wall 17 Segment Model

1.2.840.10008.6.​1.​219

CID 3718

Myocardial Wall Segments in Projection

1.2.840.10008.6.​1.​220

CID 3719

Canadian Clinical Classification

1.2.840.10008.6.​1.​221

CID 3720

Cardiac History Date (Retired)

RET (2007)

1.2.840.10008.6.​1.​222

CID 3721

Cardiovascular Surgery

1.2.840.10008.6.​1.​223

CID 3722

Diabetic Therapy

1.2.840.10008.6.​1.​224

CID 3723

MI Type

1.2.840.10008.6.​1.​225

CID 3724

Smoking History

1.2.840.10008.6.​1.​226

CID 3726

Coronary Intervention Indication

1.2.840.10008.6.​1.​227

CID 3727

Catheterization Indication

1.2.840.10008.6.​1.​228

CID 3728

Cath Finding

1.2.840.10008.6.​1.​229

CID 3729

Admission Status

1.2.840.10008.6.​1.​230

CID 3730

Insurance Payor

1.2.840.10008.6.​1.​231

CID 3733

Primary Cause of Death

1.2.840.10008.6.​1.​232

CID 3735

Acute Coronary Syndrome Time Period

1.2.840.10008.6.​1.​233

CID 3736

NYHA Classification

1.2.840.10008.6.​1.​234

CID 3737

Ischemia Non-invasive Test

1.2.840.10008.6.​1.​235

CID 3738

Pre-Cath Angina Type

1.2.840.10008.6.​1.​236

CID 3739

Cath Procedure Type

1.2.840.10008.6.​1.​237

CID 3740

Thrombolytic Administration

1.2.840.10008.6.​1.​238

CID 3741

Lab Visit Medication Administration

1.2.840.10008.6.​1.​239

CID 3742

PCI Medication Administration

1.2.840.10008.6.​1.​240

CID 3743

Clopidogrel/Ticlopidine Administration

1.2.840.10008.6.​1.​241

CID 3744

EF Testing Method

1.2.840.10008.6.​1.​242

CID 3745

Calculation Method

1.2.840.10008.6.​1.​243

CID 3746

Percutaneous Entry Site

1.2.840.10008.6.​1.​244

CID 3747

Percutaneous Closure

1.2.840.10008.6.​1.​245

CID 3748

Angiographic EF Testing Method

1.2.840.10008.6.​1.​246

CID 3749

PCI Procedure Result

1.2.840.10008.6.​1.​247

CID 3750

Previously Dilated Lesion

1.2.840.10008.6.​1.​248

CID 3752

Guidewire Crossing

1.2.840.10008.6.​1.​249

CID 3754

Vascular Complication

1.2.840.10008.6.​1.​250

CID 3755

Cath Complication

1.2.840.10008.6.​1.​251

CID 3756

Cardiac Patient Risk Factor

1.2.840.10008.6.​1.​252

CID 3757

Cardiac Diagnostic Procedure

1.2.840.10008.6.​1.​253

CID 3758

Cardiovascular Family History

1.2.840.10008.6.​1.​254

CID 3760

Hypertension Therapy

1.2.840.10008.6.​1.​255

CID 3761

Antilipemic Agent

1.2.840.10008.6.​1.​256

CID 3762

Antiarrhythmic Agent

1.2.840.10008.6.​1.​257

CID 3764

Myocardial Infarction Therapy

1.2.840.10008.6.​1.​258

CID 3769

Concern Type

1.2.840.10008.6.​1.​259

CID 3770

Problem Status

1.2.840.10008.6.​1.​260

CID 3772

Health Status

1.2.840.10008.6.​1.​261

CID 3773

Use Status

1.2.840.10008.6.​1.​262

CID 3774

Social History

1.2.840.10008.6.​1.​263

CID 3777

Cardiovascular Implant

1.2.840.10008.6.​1.​264

CID 3802

Plaque Structure

1.2.840.10008.6.​1.​265

CID 3804

Stenosis Measurement Method

1.2.840.10008.6.​1.​266

CID 3805

Stenosis Type

1.2.840.10008.6.​1.​267

CID 3806

Stenosis Shape

1.2.840.10008.6.​1.​268

CID 3807

Volume Measurement Method

1.2.840.10008.6.​1.​269

CID 3808

Aneurysm Type

1.2.840.10008.6.​1.​270

CID 3809

Associated Condition

1.2.840.10008.6.​1.​271

CID 3810

Vascular Morphology

1.2.840.10008.6.​1.​272

CID 3813

Stent Finding

1.2.840.10008.6.​1.​273

CID 3814

Stent Composition

1.2.840.10008.6.​1.​274

CID 3815

Source of Vascular Finding

1.2.840.10008.6.​1.​275

CID 3817

Vascular Sclerosis Type

1.2.840.10008.6.​1.​276

CID 3820

Non-invasive Vascular Procedure

1.2.840.10008.6.​1.​277

CID 3821

Papillary Muscle Included/Excluded

1.2.840.10008.6.​1.​278

CID 3823

Respiratory Status

1.2.840.10008.6.​1.​279

CID 3826

Heart Rhythm

1.2.840.10008.6.​1.​280

CID 3827

Vessel Segment

1.2.840.10008.6.​1.​281

CID 3829

Pulmonary Artery

1.2.840.10008.6.​1.​282

CID 3831

Stenosis Length

1.2.840.10008.6.​1.​283

CID 3832

Stenosis Grade

1.2.840.10008.6.​1.​284

CID 3833

Cardiac Ejection Fraction

1.2.840.10008.6.​1.​285

CID 3835

Cardiac Volume Measurement

1.2.840.10008.6.​1.​286

CID 3836

Time-based Perfusion Measurement

1.2.840.10008.6.​1.​287

CID 3837

Fiducial Feature

1.2.840.10008.6.​1.​288

CID 3838

Diameter Derivation

1.2.840.10008.6.​1.​289

CID 3839

Coronary Vein

1.2.840.10008.6.​1.​290

CID 3840

Pulmonary Vein

1.2.840.10008.6.​1.​291

CID 3843

Myocardial Subsegment

1.2.840.10008.6.​1.​292

CID 4005

Partial View Section for Mammography

1.2.840.10008.6.​1.​293

CID 4009

DX Anatomy Imaged

1.2.840.10008.6.​1.​294

CID 4010

DX View

1.2.840.10008.6.​1.​295

CID 4011

DX View Modifier

1.2.840.10008.6.​1.​296

CID 4012

Projection Eponymous Name

1.2.840.10008.6.​1.​297

CID 4013

Anatomic Region for Mammography

1.2.840.10008.6.​1.​298

CID 4014

View for Mammography

1.2.840.10008.6.​1.​299

CID 4015

View Modifier for Mammography

1.2.840.10008.6.​1.​300

CID 4016

Anatomic Region for Intra-oral Radiography

1.2.840.10008.6.​1.​301

CID 4017

Anatomic Region Modifier for Intra-oral Radiography

1.2.840.10008.6.​1.​302

CID 4018

Primary Anatomic Structure for Intra-oral Radiography (Permanent Dentition - Designation of Teeth)

1.2.840.10008.6.​1.​303

CID 4019

Primary Anatomic Structure for Intra-oral Radiography (Deciduous Dentition - Designation of Teeth)

1.2.840.10008.6.​1.​304

CID 4020

PET Radionuclide

1.2.840.10008.6.​1.​305

CID 4021

PET Radiopharmaceutical

1.2.840.10008.6.​1.​306

CID 4028

Craniofacial Anatomic Region

1.2.840.10008.6.​1.​307

CID 4030

CT, MR and PET Anatomy Imaged

1.2.840.10008.6.​1.​308

CID 4031

Common Anatomic Region

1.2.840.10008.6.​1.​309

CID 4032

MR Spectroscopy Metabolite

1.2.840.10008.6.​1.​310

CID 4033

MR Proton Spectroscopy Metabolite

1.2.840.10008.6.​1.​311

CID 4040

Endoscopy Anatomic Region

1.2.840.10008.6.​1.​312

CID 4042

XA/XRF Anatomy Imaged

1.2.840.10008.6.​1.​313

CID 4050

Drug or Contrast Agent Characteristic

1.2.840.10008.6.​1.​314

CID 4051

General Device

1.2.840.10008.6.​1.​315

CID 4052

Phantom Device

1.2.840.10008.6.​1.​316

CID 4200

Ophthalmic Imaging Agent

1.2.840.10008.6.​1.​317

CID 4201

Patient Eye Movement Command

1.2.840.10008.6.​1.​318

CID 4202

Ophthalmic Photography Acquisition Device

1.2.840.10008.6.​1.​319

CID 4203

Ophthalmic Photography Illumination

1.2.840.10008.6.​1.​320

CID 4204

Ophthalmic Filter

1.2.840.10008.6.​1.​321

CID 4205

Ophthalmic Lens

1.2.840.10008.6.​1.​322

CID 4206

Ophthalmic Channel Description

1.2.840.10008.6.​1.​323

CID 4207

Ophthalmic Image Position

1.2.840.10008.6.​1.​324

CID 4208

Mydriatic Agent

1.2.840.10008.6.​1.​325

CID 4209

Ophthalmic Anatomic Structure Imaged

1.2.840.10008.6.​1.​326

CID 4210

Ophthalmic Tomography Acquisition Device

1.2.840.10008.6.​1.​327

CID 4211

Ophthalmic OCT Anatomic Structure Imaged

1.2.840.10008.6.​1.​328

CID 5000

Language

1.2.840.10008.6.​1.​329

CID 5001

Country

1.2.840.10008.6.​1.​330

CID 6000

Overall Breast Composition

1.2.840.10008.6.​1.​331

CID 6001

Overall Breast Composition from BI-RADS®

1.2.840.10008.6.​1.​332

CID 6002

Change Since Last Mammogram or Prior Surgery

1.2.840.10008.6.​1.​333

CID 6003

Change Since Last Mammogram or Prior Surgery from BI-RADS®

1.2.840.10008.6.​1.​334

CID 6004

Mammography Shape Characteristic

1.2.840.10008.6.​1.​335

CID 6005

Shape Characteristic from BI-RADS®

1.2.840.10008.6.​1.​336

CID 6006

Mammography Margin Characteristic

1.2.840.10008.6.​1.​337

CID 6007

Margin Characteristic from BI-RADS®

1.2.840.10008.6.​1.​338

CID 6008

Density Modifier

1.2.840.10008.6.​1.​339

CID 6009

Density Modifier from BI-RADS®

1.2.840.10008.6.​1.​340

CID 6010

Mammography Calcification Type

1.2.840.10008.6.​1.​341

CID 6011

Calcification Type from BI-RADS®

1.2.840.10008.6.​1.​342

CID 6012

Calcification Distribution Modifier

1.2.840.10008.6.​1.​343

CID 6013

Calcification Distribution Modifier from BI-RADS®

1.2.840.10008.6.​1.​344

CID 6014

Mammography Single Image Finding

1.2.840.10008.6.​1.​345

CID 6015

Single Image Finding from BI-RADS®

1.2.840.10008.6.​1.​346

CID 6016

Mammography Composite Feature

1.2.840.10008.6.​1.​347

CID 6017

Composite Feature from BI-RADS®

1.2.840.10008.6.​1.​348

CID 6018

Clockface Location or Region

1.2.840.10008.6.​1.​349

CID 6019

Clockface Location or Region from BI-RADS®

1.2.840.10008.6.​1.​350

CID 6020

Quadrant Location

1.2.840.10008.6.​1.​351

CID 6021

Quadrant Location from BI-RADS®

1.2.840.10008.6.​1.​352

CID 6022

Side

1.2.840.10008.6.​1.​353

CID 6023

Side from BI-RADS®

1.2.840.10008.6.​1.​354

CID 6024

Depth

1.2.840.10008.6.​1.​355

CID 6025

Depth from BI-RADS®

1.2.840.10008.6.​1.​356

CID 6026

Mammography Assessment

1.2.840.10008.6.​1.​357

CID 6027

Assessment from BI-RADS®

1.2.840.10008.6.​1.​358

CID 6028

Mammography Recommended Follow-up

1.2.840.10008.6.​1.​359

CID 6029

Recommended Follow-up from BI-RADS®

1.2.840.10008.6.​1.​360

CID 6030

Mammography Pathology Code

1.2.840.10008.6.​1.​361

CID 6031

Benign Pathology Code from BI-RADS®

1.2.840.10008.6.​1.​362

CID 6032

High Risk Lesion Pathology Code from BI-RADS®

1.2.840.10008.6.​1.​363

CID 6033

Malignant Pathology Code from BI-RADS®

1.2.840.10008.6.​1.​364

CID 6034

CAD Output Intended Use

1.2.840.10008.6.​1.​365

CID 6035

Composite Feature Relation

1.2.840.10008.6.​1.​366

CID 6036

Feature Scope

1.2.840.10008.6.​1.​367

CID 6037

Mammography Quantitative Temporal Difference Type

1.2.840.10008.6.​1.​368

CID 6038

Mammography Qualitative Temporal Difference Type

1.2.840.10008.6.​1.​369

CID 6039

Nipple Characteristic

1.2.840.10008.6.​1.​370

CID 6040

Non-lesion Object Type

1.2.840.10008.6.​1.​371

CID 6041

Mammography Image Quality Finding

1.2.840.10008.6.​1.​372

CID 6042

Result Status

1.2.840.10008.6.​1.​373

CID 6043

Mammography CAD Analysis Type

1.2.840.10008.6.​1.​374

CID 6044

Image Quality Assessment Type

1.2.840.10008.6.​1.​375

CID 6045

Mammography Quality Control Standard Type

1.2.840.10008.6.​1.​376

CID 6046

Follow-up Interval Unit

1.2.840.10008.6.​1.​377

CID 6047

CAD Processing and Finding Summary

1.2.840.10008.6.​1.​378

CID 6048

CAD Operating Point Axis Label

1.2.840.10008.6.​1.​379

CID 6050

Breast Procedure Reported

1.2.840.10008.6.​1.​380

CID 6051

Breast Procedure Reason

1.2.840.10008.6.​1.​381

CID 6052

Breast Imaging Report Section Title

1.2.840.10008.6.​1.​382

CID 6053

Breast Imaging Report Element

1.2.840.10008.6.​1.​383

CID 6054

Breast Imaging Finding

1.2.840.10008.6.​1.​384

CID 6055

Breast Clinical Finding or Indicated Problem

1.2.840.10008.6.​1.​385

CID 6056

Associated Finding for Breast

1.2.840.10008.6.​1.​386

CID 6057

Ductography Finding for Breast

1.2.840.10008.6.​1.​387

CID 6058

Procedure Modifiers for Breast

1.2.840.10008.6.​1.​388

CID 6059

Breast Implant Type

1.2.840.10008.6.​1.​389

CID 6060

Breast Biopsy Technique

1.2.840.10008.6.​1.​390

CID 6061

Breast Imaging Procedure Modifier

1.2.840.10008.6.​1.​391

CID 6062

Interventional Procedure Complication

1.2.840.10008.6.​1.​392

CID 6063

Interventional Procedure Result

1.2.840.10008.6.​1.​393

CID 6064

Ultrasound Finding for Breast

1.2.840.10008.6.​1.​394

CID 6065

Instrument Approach

1.2.840.10008.6.​1.​395

CID 6066

Target Confirmation

1.2.840.10008.6.​1.​396

CID 6067

Fluid Color

1.2.840.10008.6.​1.​397

CID 6068

Tumor Stages From AJCC

1.2.840.10008.6.​1.​398

CID 6069

Nottingham Combined Histologic Grade

1.2.840.10008.6.​1.​399

CID 6070

Bloom-Richardson Histologic Grade

1.2.840.10008.6.​1.​400

CID 6071

Histologic Grading Method

1.2.840.10008.6.​1.​401

CID 6072

Breast Implant Finding

1.2.840.10008.6.​1.​402

CID 6080

Gynecological Hormone

1.2.840.10008.6.​1.​403

CID 6081

Breast Cancer Risk Factor

1.2.840.10008.6.​1.​404

CID 6082

Gynecological Procedure

1.2.840.10008.6.​1.​405

CID 6083

Procedures for Breast

1.2.840.10008.6.​1.​406

CID 6084

Mammoplasty Procedure

1.2.840.10008.6.​1.​407

CID 6085

Therapies for Breast

1.2.840.10008.6.​1.​408

CID 6086

Menopausal Phase

1.2.840.10008.6.​1.​409

CID 6087

General Risk Factor

1.2.840.10008.6.​1.​410

CID 6088

OB-GYN Maternal Risk Factor

1.2.840.10008.6.​1.​411

CID 6089

Substance

1.2.840.10008.6.​1.​412

CID 6090

Relative Usage/Exposure Amount

1.2.840.10008.6.​1.​413

CID 6091

Relative Frequency of Event Value

1.2.840.10008.6.​1.​414

CID 6092

Usage/Exposure Qualitative Concept

1.2.840.10008.6.​1.​415

CID 6093

Usage/Exposure/Amount Qualitative Concept

1.2.840.10008.6.​1.​416

CID 6094

Usage/Exposure/Frequency Qualitative Concept

1.2.840.10008.6.​1.​417

CID 6095

Procedure Numeric Property

1.2.840.10008.6.​1.​418

CID 6096

Pregnancy Status

1.2.840.10008.6.​1.​419

CID 6097

Side of Family

1.2.840.10008.6.​1.​420

CID 6100

Chest Component Category

1.2.840.10008.6.​1.​421

CID 6101

Chest Finding or Feature

1.2.840.10008.6.​1.​422

CID 6102

Chest Finding or Feature Modifier

1.2.840.10008.6.​1.​423

CID 6103

Abnormal Lines Finding or Feature

1.2.840.10008.6.​1.​424

CID 6104

Abnormal Opacity Finding or Feature

1.2.840.10008.6.​1.​425

CID 6105

Abnormal Lucency Finding or Feature

1.2.840.10008.6.​1.​426

CID 6106

Abnormal Texture Finding or Feature

1.2.840.10008.6.​1.​427

CID 6107

Width Descriptor

1.2.840.10008.6.​1.​428

CID 6108

Chest Anatomic Structure Abnormal Distribution

1.2.840.10008.6.​1.​429

CID 6109

Radiographic Anatomy Finding or Feature

1.2.840.10008.6.​1.​430

CID 6110

Lung Anatomy Finding or Feature

1.2.840.10008.6.​1.​431

CID 6111

Bronchovascular Anatomy Finding or Feature

1.2.840.10008.6.​1.​432

CID 6112

Pleura Anatomy Finding or Feature

1.2.840.10008.6.​1.​433

CID 6113

Mediastinum Anatomy Finding or Feature

1.2.840.10008.6.​1.​434

CID 6114

Osseous Anatomy Finding or Feature

1.2.840.10008.6.​1.​435

CID 6115

Osseous Anatomy Modifier

1.2.840.10008.6.​1.​436

CID 6116

Muscular Anatomy

1.2.840.10008.6.​1.​437

CID 6117

Vascular Anatomy

1.2.840.10008.6.​1.​438

CID 6118

Size Descriptor

1.2.840.10008.6.​1.​439

CID 6119

Chest Border Shape

1.2.840.10008.6.​1.​440

CID 6120

Chest Border Definition

1.2.840.10008.6.​1.​441

CID 6121

Chest Orientation Descriptor

1.2.840.10008.6.​1.​442

CID 6122

Chest Content Descriptor

1.2.840.10008.6.​1.​443

CID 6123

Chest Opacity Descriptor

1.2.840.10008.6.​1.​444

CID 6124

Location in Chest

1.2.840.10008.6.​1.​445

CID 6125

General Chest Location

1.2.840.10008.6.​1.​446

CID 6126

Location in Lung

1.2.840.10008.6.​1.​447

CID 6127

Segment Location in Lung

1.2.840.10008.6.​1.​448

CID 6128

Chest Distribution Descriptor

1.2.840.10008.6.​1.​449

CID 6129

Chest Site Involvement

1.2.840.10008.6.​1.​450

CID 6130

Severity Descriptor

1.2.840.10008.6.​1.​451

CID 6131

Chest Texture Descriptor

1.2.840.10008.6.​1.​452

CID 6132

Chest Calcification Descriptor

1.2.840.10008.6.​1.​453

CID 6133

Chest Quantitative Temporal Difference Type

1.2.840.10008.6.​1.​454

CID 6134

Chest Qualitative Temporal Difference Type

1.2.840.10008.6.​1.​455

CID 6135

Image Quality Finding

1.2.840.10008.6.​1.​456

CID 6136

Chest Types of Quality Control Standard

1.2.840.10008.6.​1.​457

CID 6137

CAD Analysis Type

1.2.840.10008.6.​1.​458

CID 6138

Chest Non-lesion Object Type

1.2.840.10008.6.​1.​459

CID 6139

Non-lesion Modifier

1.2.840.10008.6.​1.​460

CID 6140

Calculation Method

1.2.840.10008.6.​1.​461

CID 6141

Attenuation Coefficient Measurement

1.2.840.10008.6.​1.​462

CID 6142

Calculated Value

1.2.840.10008.6.​1.​463

CID 6143

Lesion Response

1.2.840.10008.6.​1.​464

CID 6144

RECIST Defined Lesion Response

1.2.840.10008.6.​1.​465

CID 6145

Baseline Category

1.2.840.10008.6.​1.​466

CID 6151

Background Echotexture

1.2.840.10008.6.​1.​467

CID 6152

Orientation

1.2.840.10008.6.​1.​468

CID 6153

Lesion Boundary

1.2.840.10008.6.​1.​469

CID 6154

Echo Pattern

1.2.840.10008.6.​1.​470

CID 6155

Posterior Acoustic Feature

1.2.840.10008.6.​1.​471

CID 6157

Vascularity

1.2.840.10008.6.​1.​472

CID 6158

Correlation to Other Finding

1.2.840.10008.6.​1.​473

CID 6159

Malignancy Type

1.2.840.10008.6.​1.​474

CID 6160

Breast Primary Tumor Assessment From AJCC

1.2.840.10008.6.​1.​475

CID 6161

Pathological Regional Lymph Node Assessment for Breast

1.2.840.10008.6.​1.​476

CID 6162

Assessment of Metastasis for Breast

1.2.840.10008.6.​1.​477

CID 6163

Menstrual Cycle Phase

1.2.840.10008.6.​1.​478

CID 6164

Time Interval

1.2.840.10008.6.​1.​479

CID 6165

Breast Linear Measurement

1.2.840.10008.6.​1.​480

CID 6166

CAD Geometry Secondary Graphical Representation

1.2.840.10008.6.​1.​481

CID 7000

Diagnostic Imaging Report Document Title

1.2.840.10008.6.​1.​482

CID 7001

Diagnostic Imaging Report Heading

1.2.840.10008.6.​1.​483

CID 7002

Diagnostic Imaging Report Element

1.2.840.10008.6.​1.​484

CID 7003

Diagnostic Imaging Report Purpose of Reference

1.2.840.10008.6.​1.​485

CID 7004

Waveform Purpose of Reference

1.2.840.10008.6.​1.​486

CID 7005

Contributing Equipment Purpose of Reference

1.2.840.10008.6.​1.​487

CID 7006

SR Document Purpose of Reference

1.2.840.10008.6.​1.​488

CID 7007

Signature Purpose

1.2.840.10008.6.​1.​489

CID 7008

Media Import

1.2.840.10008.6.​1.​490

CID 7010

Key Object Selection Document Title

1.2.840.10008.6.​1.​491

CID 7011

Rejected for Quality Reason

1.2.840.10008.6.​1.​492

CID 7012

Best in Set

1.2.840.10008.6.​1.​493

CID 7020

Document Title

1.2.840.10008.6.​1.​494

CID 7100

RCS Registration Method Type

1.2.840.10008.6.​1.​495

CID 7101

Brain Atlas Fiducial

1.2.840.10008.6.​1.​496

CID 7150

Segmentation Property Category

1.2.840.10008.6.​1.​497

CID 7151

Segmentation Property Type

1.2.840.10008.6.​1.​498

CID 7152

Cardiac Structure Segmentation Type

1.2.840.10008.6.​1.​499

CID 7153

CNS Segmentation Type

1.2.840.10008.6.​1.​500

CID 7154

Abdominal Segmentation Type

1.2.840.10008.6.​1.​501

CID 7155

Thoracic Segmentation Type

1.2.840.10008.6.​1.​502

CID 7156

Vascular Segmentation Type

1.2.840.10008.6.​1.​503

CID 7157

Device Segmentation Type

1.2.840.10008.6.​1.​504

CID 7158

Artifact Segmentation Type

1.2.840.10008.6.​1.​505

CID 7159

Lesion Segmentation Type

1.2.840.10008.6.​1.​506

CID 7160

Pelvic Organ Segmentation Type

1.2.840.10008.6.​1.​507

CID 7161

Physiology Segmentation Type

1.2.840.10008.6.​1.​508

CID 7201

Referenced Image Purpose of Reference

1.2.840.10008.6.​1.​509

CID 7202

Source Image Purpose of Reference

1.2.840.10008.6.​1.​510

CID 7203

Image Derivation

1.2.840.10008.6.​1.​511

CID 7205

Purpose of Reference to Alternate Representation

1.2.840.10008.6.​1.​512

CID 7210

Related Series Purpose of Reference

1.2.840.10008.6.​1.​513

CID 7250

Multi-Frame Subset Type

1.2.840.10008.6.​1.​514

CID 7450

Person Role

1.2.840.10008.6.​1.​515

CID 7451

Family Member

1.2.840.10008.6.​1.​516

CID 7452

Organizational Role

1.2.840.10008.6.​1.​517

CID 7453

Performing Role

1.2.840.10008.6.​1.​518

CID 7454

Animal Taxonomic Rank Value

1.2.840.10008.6.​1.​519

CID 7455

Sex

1.2.840.10008.6.​1.​520

CID 7456

Age Unit

1.2.840.10008.6.​1.​521

CID 7460

Linear Measurement Unit

1.2.840.10008.6.​1.​522

CID 7461

Area Measurement Unit

1.2.840.10008.6.​1.​523

CID 7462

Volume Measurement Unit

1.2.840.10008.6.​1.​524

CID 7470

Linear Measurement

1.2.840.10008.6.​1.​525

CID 7471

Area Measurement

1.2.840.10008.6.​1.​526

CID 7472

Volume Measurement

1.2.840.10008.6.​1.​527

CID 7473

General Area Calculation Method

1.2.840.10008.6.​1.​528

CID 7474

General Volume Calculation Method

1.2.840.10008.6.​1.​529

CID 7480

Breed

1.2.840.10008.6.​1.​530

CID 7481

Breed Registry

1.2.840.10008.6.​1.​531

CID 9231

Workitem Definition

1.2.840.10008.6.​1.​532

CID 9232

Non-DICOM Output Types (Retired)

RET (2011)

1.2.840.10008.6.​1.​533

CID 9300

Procedure Discontinuation Reason

1.2.840.10008.6.​1.​534

CID 10000

Scope of Accumulation

1.2.840.10008.6.​1.​535

CID 10001

UID Type

1.2.840.10008.6.​1.​536

CID 10002

Irradiation Event Type

1.2.840.10008.6.​1.​537

CID 10003

Equipment Plane Identification

1.2.840.10008.6.​1.​538

CID 10004

Fluoro Mode

1.2.840.10008.6.​1.​539

CID 10006

X-Ray Filter Material

1.2.840.10008.6.​1.​540

CID 10007

X-Ray Filter Type

1.2.840.10008.6.​1.​541

CID 10008

Dose Related Distance Measurement

1.2.840.10008.6.​1.​542

CID 10009

Measured/Calculated

1.2.840.10008.6.​1.​543

CID 10010

Dose Measurement Device

1.2.840.10008.6.​1.​544

CID 10011

Effective Dose Evaluation Method

1.2.840.10008.6.​1.​545

CID 10013

CT Acquisition Type

1.2.840.10008.6.​1.​546

CID 10014

Contrast Imaging Technique

1.2.840.10008.6.​1.​547

CID 10015

CT Dose Reference Authority

1.2.840.10008.6.​1.​548

CID 10016

Anode Target Material

1.2.840.10008.6.​1.​549

CID 10017

X-Ray Grid

1.2.840.10008.6.​1.​550

CID 12001

Ultrasound Protocol Type

1.2.840.10008.6.​1.​551

CID 12002

Ultrasound Protocol Stage Type

1.2.840.10008.6.​1.​552

CID 12003

OB-GYN Date

1.2.840.10008.6.​1.​553

CID 12004

Fetal Biometry Ratio

1.2.840.10008.6.​1.​554

CID 12005

Fetal Biometry Measurement

1.2.840.10008.6.​1.​555

CID 12006

Fetal Long Bones Biometry Measurement

1.2.840.10008.6.​1.​556

CID 12007

Fetal Cranium Measurement

1.2.840.10008.6.​1.​557

CID 12008

OB-GYN Amniotic Sac Measurement

1.2.840.10008.6.​1.​558

CID 12009

Early Gestation Biometry Measurement

1.2.840.10008.6.​1.​559

CID 12011

Ultrasound Pelvis and Uterus Measurement

1.2.840.10008.6.​1.​560

CID 12012

OB Equation/Table

1.2.840.10008.6.​1.​561

CID 12013

Gestational Age Equation/Table

1.2.840.10008.6.​1.​562

CID 12014

OB Fetal Body Weight Equation/Table

1.2.840.10008.6.​1.​563

CID 12015

Fetal Growth Equation/Table

1.2.840.10008.6.​1.​564

CID 12016

Estimated Fetal Weight Percentile Equation/Table

1.2.840.10008.6.​1.​565

CID 12017

Growth Distribution Rank

1.2.840.10008.6.​1.​566

CID 12018

OB-GYN Summary

1.2.840.10008.6.​1.​567

CID 12019

OB-GYN Fetus Summary

1.2.840.10008.6.​1.​568

CID 12101

Vascular Summary

1.2.840.10008.6.​1.​569

CID 12102

Temporal Period Relating to Procedure or Therapy

1.2.840.10008.6.​1.​570

CID 12103

Vascular Ultrasound Anatomic Location

1.2.840.10008.6.​1.​571

CID 12104

Extracranial Artery

1.2.840.10008.6.​1.​572

CID 12105

Intracranial Cerebral Vessel

1.2.840.10008.6.​1.​573

CID 12106

Intracranial Cerebral Vessel (Unilateral)

1.2.840.10008.6.​1.​574

CID 12107

Upper Extremity Artery

1.2.840.10008.6.​1.​575

CID 12108

Upper Extremity Vein

1.2.840.10008.6.​1.​576

CID 12109

Lower Extremity Artery

1.2.840.10008.6.​1.​577

CID 12110

Lower Extremity Vein

1.2.840.10008.6.​1.​578

CID 12111

Abdominopelvic Artery (Paired)

1.2.840.10008.6.​1.​579

CID 12112

Abdominopelvic Artery (Unpaired)

1.2.840.10008.6.​1.​580

CID 12113

Abdominopelvic Vein (Paired)

1.2.840.10008.6.​1.​581

CID 12114

Abdominopelvic Vein (Unpaired)

1.2.840.10008.6.​1.​582

CID 12115

Renal Vessel

1.2.840.10008.6.​1.​583

CID 12116

Vessel Segment Modifier

1.2.840.10008.6.​1.​584

CID 12117

Vessel Branch Modifier

1.2.840.10008.6.​1.​585

CID 12119

Vascular Ultrasound Property

1.2.840.10008.6.​1.​586

CID 12120

Ultrasound Blood Velocity Measurement

1.2.840.10008.6.​1.​587

CID 12121

Vascular Index/Ratio

1.2.840.10008.6.​1.​588

CID 12122

Other Vascular Property

1.2.840.10008.6.​1.​589

CID 12123

Carotid Ratio

1.2.840.10008.6.​1.​590

CID 12124

Renal Ratio

1.2.840.10008.6.​1.​591

CID 12140

Pelvic Vasculature Anatomical Location

1.2.840.10008.6.​1.​592

CID 12141

Fetal Vasculature Anatomical Location

1.2.840.10008.6.​1.​593

CID 12200

Echocardiography Left Ventricle Measurement

1.2.840.10008.6.​1.​594

CID 12201

Left Ventricle Linear Measurement

1.2.840.10008.6.​1.​595

CID 12202

Left Ventricle Volume Measurement

1.2.840.10008.6.​1.​596

CID 12203

Left Ventricle Other Measurement

1.2.840.10008.6.​1.​597

CID 12204

Echocardiography Right Ventricle Measurement

1.2.840.10008.6.​1.​598

CID 12205

Echocardiography Left Atrium Measurement

1.2.840.10008.6.​1.​599

CID 12206

Echocardiography Right Atrium Measurement

1.2.840.10008.6.​1.​600

CID 12207

Echocardiography Mitral Valve Measurement

1.2.840.10008.6.​1.​601

CID 12208

Echocardiography Tricuspid Valve Measurement

1.2.840.10008.6.​1.​602

CID 12209

Echocardiography Pulmonic Valve Measurement

1.2.840.10008.6.​1.​603

CID 12210

Echocardiography Pulmonary Artery Measurement

1.2.840.10008.6.​1.​604

CID 12211

Echocardiography Aortic Valve Measurement

1.2.840.10008.6.​1.​605

CID 12212

Echocardiography Aorta Measurement

1.2.840.10008.6.​1.​606

CID 12214

Echocardiography Pulmonary Vein Measurement

1.2.840.10008.6.​1.​607

CID 12215

Echocardiography Vena Cava Measurement

1.2.840.10008.6.​1.​608

CID 12216

Echocardiography Hepatic Vein Measurement

1.2.840.10008.6.​1.​609

CID 12217

Echocardiography Cardiac Shunt Measurement

1.2.840.10008.6.​1.​610

CID 12218

Echocardiography Congenital Anomaly Measurement

1.2.840.10008.6.​1.​611

CID 12219

Pulmonary Vein Modifier

1.2.840.10008.6.​1.​612

CID 12220

Echocardiography Common Measurement

1.2.840.10008.6.​1.​613

CID 12221

Flow Direction

1.2.840.10008.6.​1.​614

CID 12222

Orifice Flow Property

1.2.840.10008.6.​1.​615

CID 12223

Echocardiography Stroke Volume Origin

1.2.840.10008.6.​1.​616

CID 12224

Ultrasound Image Mode

1.2.840.10008.6.​1.​617

CID 12226

Echocardiography Image View

1.2.840.10008.6.​1.​618

CID 12227

Echocardiography Measurement Method

1.2.840.10008.6.​1.​619

CID 12228

Echocardiography Volume Method

1.2.840.10008.6.​1.​620

CID 12229

Echocardiography Area Method

1.2.840.10008.6.​1.​621

CID 12230

Gradient Method

1.2.840.10008.6.​1.​622

CID 12231

Volume Flow Method

1.2.840.10008.6.​1.​623

CID 12232

Myocardium Mass Method

1.2.840.10008.6.​1.​624

CID 12233

Cardiac Phase

1.2.840.10008.6.​1.​625

CID 12234

Respiration State

1.2.840.10008.6.​1.​626

CID 12235

Mitral Valve Anatomic Site

1.2.840.10008.6.​1.​627

CID 12236

Echocardiography Anatomic Site

1.2.840.10008.6.​1.​628

CID 12237

Echocardiography Anatomic Site Modifier

1.2.840.10008.6.​1.​629

CID 12238

Wall Motion Scoring Scheme

1.2.840.10008.6.​1.​630

CID 12239

Cardiac Output Property

1.2.840.10008.6.​1.​631

CID 12240

Left Ventricle Area Measurement

1.2.840.10008.6.​1.​632

CID 12241

Tricuspid Valve Finding Site

1.2.840.10008.6.​1.​633

CID 12242

Aortic Valve Finding Site

1.2.840.10008.6.​1.​634

CID 12243

Left Ventricle Finding Site

1.2.840.10008.6.​1.​635

CID 12244

Congenital Finding Site

1.2.840.10008.6.​1.​636

CID 7162

Surface Processing Algorithm Family

1.2.840.10008.6.​1.​637

CID 3207

Stress Test Procedure Phase

1.2.840.10008.6.​1.​638

CID 3778

Stage

1.2.840.10008.6.​1.​735

CID 252

S-M-L Size Descriptor

1.2.840.10008.6.​1.​736

CID 3016

Major Coronary Artery

1.2.840.10008.6.​1.​737

CID 3083

Radioactivity Unit

1.2.840.10008.6.​1.​738

CID 3102

Rest/Stress State

1.2.840.10008.6.​1.​739

CID 3106

PET Cardiology Protocol

1.2.840.10008.6.​1.​740

CID 3107

PET Cardiology Radiopharmaceutical

1.2.840.10008.6.​1.​741

CID 3108

NM/PET Procedure

1.2.840.10008.6.​1.​742

CID 3110

Nuclear Cardiology Protocol

1.2.840.10008.6.​1.​743

CID 3111

Nuclear Cardiology Radiopharmaceutical

1.2.840.10008.6.​1.​744

CID 3112

Attenuation Correction

1.2.840.10008.6.​1.​745

CID 3113

Perfusion Defect Type

1.2.840.10008.6.​1.​746

CID 3114

Study Quality

1.2.840.10008.6.​1.​747

CID 3115

Stress Imaging Quality Issue

1.2.840.10008.6.​1.​748

CID 3116

NM Extracardiac Finding

1.2.840.10008.6.​1.​749

CID 3117

Attenuation Correction Method

1.2.840.10008.6.​1.​750

CID 3118

Level of Risk

1.2.840.10008.6.​1.​751

CID 3119

LV Function

1.2.840.10008.6.​1.​752

CID 3120

Perfusion Finding

1.2.840.10008.6.​1.​753

CID 3121

Perfusion Morphology

1.2.840.10008.6.​1.​754

CID 3122

Ventricular Enlargement

1.2.840.10008.6.​1.​755

CID 3200

Stress Test Procedure

1.2.840.10008.6.​1.​756

CID 3201

Indications for Stress Test

1.2.840.10008.6.​1.​757

CID 3202

Chest Pain

1.2.840.10008.6.​1.​758

CID 3203

Exerciser Device

1.2.840.10008.6.​1.​759

CID 3204

Stress Agent

1.2.840.10008.6.​1.​760

CID 3205

Indications for Pharmacological Stress Test

1.2.840.10008.6.​1.​761

CID 3206

Non-invasive Cardiac Imaging Procedure

1.2.840.10008.6.​1.​763

CID 3208

Exercise ECG Summary Code

1.2.840.10008.6.​1.​764

CID 3209

Stress Imaging Summary Code

1.2.840.10008.6.​1.​765

CID 3210

Speed of Response

1.2.840.10008.6.​1.​766

CID 3211

BP Response

1.2.840.10008.6.​1.​767

CID 3212

Treadmill Speed

1.2.840.10008.6.​1.​768

CID 3213

Stress Hemodynamic Finding

1.2.840.10008.6.​1.​769

CID 3215

Perfusion Finding Method

1.2.840.10008.6.​1.​770

CID 3217

Comparison Finding

1.2.840.10008.6.​1.​771

CID 3220

Stress Symptom

1.2.840.10008.6.​1.​772

CID 3221

Stress Test Termination Reason

1.2.840.10008.6.​1.​773

CID 3227

QTc Measurement

1.2.840.10008.6.​1.​774

CID 3228

ECG Timing Measurement

1.2.840.10008.6.​1.​775

CID 3229

ECG Axis Measurement

1.2.840.10008.6.​1.​776

CID 3230

ECG Finding

1.2.840.10008.6.​1.​777

CID 3231

ST Segment Finding

1.2.840.10008.6.​1.​778

CID 3232

ST Segment Location

1.2.840.10008.6.​1.​779

CID 3233

ST Segment Morphology

1.2.840.10008.6.​1.​780

CID 3234

Ectopic Beat Morphology

1.2.840.10008.6.​1.​781

CID 3235

Perfusion Comparison Finding

1.2.840.10008.6.​1.​782

CID 3236

Tolerance Comparison Finding

1.2.840.10008.6.​1.​783

CID 3237

Wall Motion Comparison Finding

1.2.840.10008.6.​1.​784

CID 3238

Stress Scoring Scale

1.2.840.10008.6.​1.​785

CID 3239

Perceived Exertion Scale

1.2.840.10008.6.​1.​786

CID 3463

Ventricle Identification

1.2.840.10008.6.​1.​787

CID 6200

Colon Overall Assessment

1.2.840.10008.6.​1.​788

CID 6201

Colon Finding or Feature

1.2.840.10008.6.​1.​789

CID 6202

Colon Finding or Feature Modifier

1.2.840.10008.6.​1.​790

CID 6203

Colon Non-lesion Object Type

1.2.840.10008.6.​1.​791

CID 6204

Anatomic Non-colon Finding

1.2.840.10008.6.​1.​792

CID 6205

Clockface Location for Colon

1.2.840.10008.6.​1.​793

CID 6206

Recumbent Patient Orientation for Colon

1.2.840.10008.6.​1.​794

CID 6207

Colon Quantitative Temporal Difference Type

1.2.840.10008.6.​1.​795

CID 6208

Colon Types of Quality Control Standard

1.2.840.10008.6.​1.​796

CID 6209

Colon Morphology Descriptor

1.2.840.10008.6.​1.​797

CID 6210

Location in Intestinal Tract

1.2.840.10008.6.​1.​798

CID 6211

Colon CAD Material Description

1.2.840.10008.6.​1.​799

CID 6212

Calculated Value for Colon Finding

1.2.840.10008.6.​1.​800

CID 4214

Ophthalmic Horizontal Direction

1.2.840.10008.6.​1.​801

CID 4215

Ophthalmic Vertical Direction

1.2.840.10008.6.​1.​802

CID 4216

Ophthalmic Visual Acuity Type

1.2.840.10008.6.​1.​803

CID 3004

Arterial Pulse Waveform

1.2.840.10008.6.​1.​804

CID 3005

Respiration Waveform

1.2.840.10008.6.​1.​805

CID 12030

Ultrasound Contrast/Bolus Agent

1.2.840.10008.6.​1.​806

CID 12031

Protocol Interval Event

1.2.840.10008.6.​1.​807

CID 12032

Transducer Scan Pattern

1.2.840.10008.6.​1.​808

CID 12033

Ultrasound Transducer Geometry

1.2.840.10008.6.​1.​809

CID 12034

Ultrasound Transducer Beam Steering

1.2.840.10008.6.​1.​810

CID 12035

Ultrasound Transducer Application

1.2.840.10008.6.​1.​811

CID 50

Instance Availability Status

1.2.840.10008.6.​1.​812

CID 9301

Modality PPS Discontinuation Reason

1.2.840.10008.6.​1.​813

CID 9302

Media Import PPS Discontinuation Reason

1.2.840.10008.6.​1.​814

CID 7482

DX Anatomy Imaged for Animal

1.2.840.10008.6.​1.​815

CID 7483

Common Anatomic Regions for Animal

1.2.840.10008.6.​1.​816

CID 7484

DX View for Animal

1.2.840.10008.6.​1.​817

CID 7030

Institutional Department/Unit/Service

1.2.840.10008.6.​1.​818

CID 7009

Purpose of Reference to Predecessor Report

1.2.840.10008.6.​1.​819

CID 4220

Visual Fixation Quality During Acquisition

1.2.840.10008.6.​1.​820

CID 4221

Visual Fixation Quality Problem

1.2.840.10008.6.​1.​821

CID 4222

Ophthalmic Macular Grid Problem

1.2.840.10008.6.​1.​822

CID 5002

Organization

1.2.840.10008.6.​1.​823

CID 7486

Mixed Breed

1.2.840.10008.6.​1.​824

CID 7040

Broselow-Luten Pediatric Size Category

1.2.840.10008.6.​1.​825

CID 7042

CMDCTECC Calcium Scoring Patient Size Category

1.2.840.10008.6.​1.​826

CID 12245

Cardiac Ultrasound Report Title

1.2.840.10008.6.​1.​827

CID 12246

Cardiac Ultrasound Indication for Study

1.2.840.10008.6.​1.​828

CID 12247

Pediatric, Fetal and Congenital Cardiac Surgical Intervention

1.2.840.10008.6.​1.​829

CID 12248

Cardiac Ultrasound Summary Code

1.2.840.10008.6.​1.​830

CID 12249

Cardiac Ultrasound Fetal Summary Code

1.2.840.10008.6.​1.​831

CID 12250

Cardiac Ultrasound Common Linear Measurement

1.2.840.10008.6.​1.​832

CID 12251

Cardiac Ultrasound Linear Valve Measurement

1.2.840.10008.6.​1.​833

CID 12252

Cardiac Ultrasound Cardiac Function

1.2.840.10008.6.​1.​834

CID 12253

Cardiac Ultrasound Area Measurement

1.2.840.10008.6.​1.​835

CID 12254

Cardiac Ultrasound Hemodynamic Measurement

1.2.840.10008.6.​1.​836

CID 12255

Cardiac Ultrasound Myocardium Measurement

1.2.840.10008.6.​1.​837

1.2.840.10008.6.​1.​838

CID 12257

Cardiac Ultrasound Left Ventricle Measurement

1.2.840.10008.6.​1.​839

CID 12258

Cardiac Ultrasound Right Ventricle Measurement

1.2.840.10008.6.​1.​840

CID 12259

Cardiac Ultrasound Ventricles Measurement

1.2.840.10008.6.​1.​841

CID 12260

Cardiac Ultrasound Pulmonary Artery Measurement

1.2.840.10008.6.​1.​842

CID 12261

Cardiac Ultrasound Pulmonary Vein

1.2.840.10008.6.​1.​843

CID 12262

Cardiac Ultrasound Pulmonary Valve Measurement

1.2.840.10008.6.​1.​844

CID 12263

Cardiac Ultrasound Venous Return Pulmonary Measurement

1.2.840.10008.6.​1.​845

CID 12264

Cardiac Ultrasound Venous Return Systemic Measurement

1.2.840.10008.6.​1.​846

CID 12265

Cardiac Ultrasound Atria and Atrial Septum Measurement

1.2.840.10008.6.​1.​847

CID 12266

Cardiac Ultrasound Mitral Valve Measurement

1.2.840.10008.6.​1.​848

CID 12267

Cardiac Ultrasound Tricuspid Valve Measurement

1.2.840.10008.6.​1.​849

CID 12268

Cardiac Ultrasound Atrioventricular Valve Measurement

1.2.840.10008.6.​1.​850

CID 12269

Cardiac Ultrasound Interventricular Septum Measurement

1.2.840.10008.6.​1.​851

CID 12270

Cardiac Ultrasound Aortic Valve Measurement

1.2.840.10008.6.​1.​852

CID 12271

Cardiac Ultrasound Outflow Tract Measurement

1.2.840.10008.6.​1.​853

CID 12272

Cardiac Ultrasound Semilunar Valve, Annulate and Sinus Measurement

1.2.840.10008.6.​1.​854

CID 12273

Cardiac Ultrasound Aortic Sinotubular Junction Measurement

1.2.840.10008.6.​1.​855

CID 12274

Cardiac Ultrasound Aorta Measurement

1.2.840.10008.6.​1.​856

CID 12275

Cardiac Ultrasound Coronary Artery Measurement

1.2.840.10008.6.​1.​857

CID 12276

Cardiac Ultrasound Aorto Pulmonary Connection Measurement

1.2.840.10008.6.​1.​858

CID 12277

Cardiac Ultrasound Pericardium and Pleura Measurement

1.2.840.10008.6.​1.​859

CID 12279

Cardiac Ultrasound Fetal General Measurement

1.2.840.10008.6.​1.​860

CID 12280

Cardiac Ultrasound Target Site

1.2.840.10008.6.​1.​861

CID 12281

Cardiac Ultrasound Target Site Modifier

1.2.840.10008.6.​1.​862

CID 12282

Cardiac Ultrasound Venous Return Systemic Finding Site

1.2.840.10008.6.​1.​863

CID 12283

Cardiac Ultrasound Venous Return Pulmonary Finding Site

1.2.840.10008.6.​1.​864

CID 12284

Cardiac Ultrasound Atria and Atrial Septum Finding Site

1.2.840.10008.6.​1.​865

CID 12285

Cardiac Ultrasound Atrioventricular Valve Finding Site

1.2.840.10008.6.​1.​866

CID 12286

Cardiac Ultrasound Interventricular Septum Finding Site

1.2.840.10008.6.​1.​867

CID 12287

Cardiac Ultrasound Ventricle Finding Site

1.2.840.10008.6.​1.​868

CID 12288

Cardiac Ultrasound Outflow Tract Finding Site

1.2.840.10008.6.​1.​869

CID 12289

Cardiac Ultrasound Semilunar Valve, Annulus and Sinus Finding Site

1.2.840.10008.6.​1.​870

CID 12290

Cardiac Ultrasound Pulmonary Artery Finding Site

1.2.840.10008.6.​1.​871

CID 12291

Cardiac Ultrasound Aorta Finding Site

1.2.840.10008.6.​1.​872

CID 12292

Cardiac Ultrasound Coronary Artery Finding Site

1.2.840.10008.6.​1.​873

CID 12293

Cardiac Ultrasound Aortopulmonary Connection Finding Site

1.2.840.10008.6.​1.​874

CID 12294

Cardiac Ultrasound Pericardium and Pleura Finding Site

1.2.840.10008.6.​1.​876

CID 4230

Ophthalmic Ultrasound Axial Measurements Type

1.2.840.10008.6.​1.​877

CID 4231

Lens Status

1.2.840.10008.6.​1.​878

CID 4232

Vitreous Status

1.2.840.10008.6.​1.​879

CID 4233

Ophthalmic Axial Length Measurements Segment Name

1.2.840.10008.6.​1.​880

CID 4234

Refractive Surgery Type

1.2.840.10008.6.​1.​881

CID 4235

Keratometry Descriptor

1.2.840.10008.6.​1.​882

CID 4236

IOL Calculation Formula

1.2.840.10008.6.​1.​883

CID 4237

Lens Constant Type

1.2.840.10008.6.​1.​884

CID 4238

Refractive Error Type

1.2.840.10008.6.​1.​885

CID 4239

Anterior Chamber Depth Definition

1.2.840.10008.6.​1.​886

CID 4240

Ophthalmic Measurement or Calculation Data Source

1.2.840.10008.6.​1.​887

CID 4241

Ophthalmic Axial Length Selection Method

1.2.840.10008.6.​1.​888

Retired

1.2.840.10008.6.​1.​889

CID 4243

Ophthalmic Quality Metric Type

1.2.840.10008.6.​1.​890

CID 4244

Ophthalmic Agent Concentration Unit

1.2.840.10008.6.​1.​891

CID 91

Functional Condition Present During Acquisition

1.2.840.10008.6.​1.​892

CID 92

Joint Position During Acquisition

1.2.840.10008.6.​1.​893

CID 93

Joint Positioning Method

1.2.840.10008.6.​1.​894

CID 94

Physical Force Applied During Acquisition

1.2.840.10008.6.​1.​895

CID 3690

ECG Control Numeric Variable

1.2.840.10008.6.​1.​896

CID 3691

ECG Control Text Variable

1.2.840.10008.6.​1.​897

CID 8120

Whole Slide Microscopy Image Referenced Image Purpose of Reference

1.2.840.10008.6.​1.​898

CID 8121

Microscopy Lens Type

1.2.840.10008.6.​1.​899

CID 8122

Microscopy Illuminator and Sensor Color

1.2.840.10008.6.​1.​900

CID 8123

Microscopy Illumination Method

1.2.840.10008.6.​1.​901

CID 8124

Microscopy Filter

1.2.840.10008.6.​1.​902

CID 8125

Microscopy Illuminator Type

1.2.840.10008.6.​1.​903

CID 400

Audit Event ID

1.2.840.10008.6.​1.​904

CID 401

Audit Event Type Code

1.2.840.10008.6.​1.​905

CID 402

Audit Active Participant Role ID Code

1.2.840.10008.6.​1.​906

CID 403

Security Alert Type Code

1.2.840.10008.6.​1.​907

CID 404

Audit Participant Object ID Type Code

1.2.840.10008.6.​1.​908

CID 405

Media Type Code

1.2.840.10008.6.​1.​909

CID 4250

Visual Field Static Perimetry Test Pattern

1.2.840.10008.6.​1.​910

CID 4251

Visual Field Static Perimetry Test Strategy

1.2.840.10008.6.​1.​911

CID 4252

Visual Field Static Perimetry Screening Test Mode

1.2.840.10008.6.​1.​912

CID 4253

Visual Field Static Perimetry Fixation Strategy

1.2.840.10008.6.​1.​913

CID 4254

Visual Field Static Perimetry Test Analysis Result

1.2.840.10008.6.​1.​914

CID 4255

Visual Field Illumination Color

1.2.840.10008.6.​1.​915

CID 4256

Visual Field Procedure Modifier

1.2.840.10008.6.​1.​916

CID 4257

Visual Field Global Index Name

1.2.840.10008.6.​1.​917

CID 7180

Abstract Multi-dimensional Image Model Component Semantic

1.2.840.10008.6.​1.​918

CID 7181

Abstract Multi-dimensional Image Model Component Unit

1.2.840.10008.6.​1.​919

CID 7182

Abstract Multi-dimensional Image Model Dimension Semantic

1.2.840.10008.6.​1.​920

CID 7183

Abstract Multi-dimensional Image Model Dimension Unit

1.2.840.10008.6.​1.​921

CID 7184

Abstract Multi-dimensional Image Model Axis Direction

1.2.840.10008.6.​1.​922

CID 7185

Abstract Multi-dimensional Image Model Axis Orientation

1.2.840.10008.6.​1.​923

CID 7186

Abstract Multi-dimensional Image Model Qualitative Dimension Sample Semantic

1.2.840.10008.6.​1.​924

CID 7320

Planning Method

1.2.840.10008.6.​1.​925

CID 7050

De-identification Method

1.2.840.10008.6.​1.​926

CID 12118

Measurement Orientation

1.2.840.10008.6.​1.​927

CID 3689

ECG Global Waveform Duration

1.2.840.10008.6.​1.​930

CID 3692

ICD

1.2.840.10008.6.​1.​931

CID 9241

Radiotherapy General Workitem Definition

1.2.840.10008.6.​1.​932

CID 9242

Radiotherapy Acquisition Workitem Definition

1.2.840.10008.6.​1.​933

CID 9243

Radiotherapy Registration Workitem Definition

1.2.840.10008.6.​1.​934

CID 3850

Contrast Bolus Substance

1.2.840.10008.6.​1.​935

CID 10022

Label Type

1.2.840.10008.6.​1.​936

CID 4260

Ophthalmic Mapping Unit for Real World Value Mapping

1.2.840.10008.6.​1.​937

CID 4261

Ophthalmic Mapping Acquisition Method

1.2.840.10008.6.​1.​938

CID 4262

Retinal Thickness Definition

1.2.840.10008.6.​1.​939

CID 4263

Ophthalmic Thickness Map Value Type

1.2.840.10008.6.​1.​940

CID 4264

Ophthalmic Map Purpose of Reference

1.2.840.10008.6.​1.​941

CID 4265

Ophthalmic Thickness Deviation Category

1.2.840.10008.6.​1.​942

CID 4266

Ophthalmic Anatomic Structure Reference Point

1.2.840.10008.6.​1.​943

CID 3104

Cardiac Synchronization Technique

1.2.840.10008.6.​1.​944

CID 8130

Staining Protocol

1.2.840.10008.6.​1.​945

Retired

1.2.840.10008.6.​1.​946

Retired

1.2.840.10008.6.​1.​947

CID 10023

Size Specific Dose Estimation Method for CT

1.2.840.10008.6.​1.​948

CID 8131

Pathology Imaging Protocol

1.2.840.10008.6.​1.​949

CID 8132

Magnification Selection

1.2.840.10008.6.​1.​950

CID 8133

Tissue Selection

1.2.840.10008.6.​1.​951

CID 7464

General Region of Interest Measurement Modifier

1.2.840.10008.6.​1.​952

CID 7465

Measurement Derived From Multiple ROI Measurements

1.2.840.10008.6.​1.​953

CID 8201

Surface Scan Acquisition Type

1.2.840.10008.6.​1.​954

CID 8202

Surface Scan Mode Type

1.2.840.10008.6.​1.​956

CID 8203

Surface Scan Registration Method Type

1.2.840.10008.6.​1.​957

CID 27

Basic Cardiac View

1.2.840.10008.6.​1.​958

CID 10033

CT Reconstruction Algorithm

1.2.840.10008.6.​1.​959

CID 10030

Detector Type

1.2.840.10008.6.​1.​960

CID 10031

CR/DR Mechanical Configuration

1.2.840.10008.6.​1.​961

CID 10032

Projection X-Ray Acquisition Device Type

1.2.840.10008.6.​1.​962

CID 7165

Abstract Segmentation Type

1.2.840.10008.6.​1.​963

CID 7166

Common Tissue Segmentation Type

1.2.840.10008.6.​1.​964

CID 7167

Peripheral Nervous System Segmentation Type

1.2.840.10008.6.​1.​965

CID 4267

Corneal Topography Mapping Unit for Real World Value Mapping

1.2.840.10008.6.​1.​966

CID 4268

Corneal Topography Map Value Type

1.2.840.10008.6.​1.​967

CID 7140

Brain Structure for Volumetric Measurement

1.2.840.10008.6.​1.​968

CID 7220

RT Dose Derivation

1.2.840.10008.6.​1.​969

CID 7221

RT Dose Purpose of Reference

1.2.840.10008.6.1.970

CID 7215

Spectroscopy Purpose of Reference

1.2.840.10008.6.​1.​971

CID 9250

Scheduled Processing Parameter Concept Codes for RT Treatment

1.2.840.10008.6.1.972

CID 10040

Radiopharmaceutical Organ Dose Reference Authority

1.2.840.10008.6.1.973

CID 10041

Source of Radioisotope Activity Information

1.2.840.10008.6.1.975

CID 10043

Intravenous Extravasation Symptom

1.2.840.10008.6.1.976

CID 10044

Radiosensitive Organ

1.2.840.10008.6.1.977

CID 10045

Radiopharmaceutical Patient State

1.2.840.10008.6.1.978

CID 10046

GFR Measurement

1.2.840.10008.6.1.979

CID 10047

GFR Measurement Method

1.2.840.10008.6.1.980

CID 8300

Visual Evaluation Method

1.2.840.10008.6.1.981

CID 8301

Test Pattern Code

1.2.840.10008.6.1.982

CID 8302

Measurement Pattern Code

1.2.840.10008.6.1.983

CID 8303

Display Device Type

1.2.840.10008.6.1.984

CID 85

SUV Unit

1.2.840.10008.6.1.985

CID 4100

T1 Measurement Method

1.2.840.10008.6.1.986

CID 4101

Tracer Kinetic Model

1.2.840.10008.6.1.987

CID 4102

Perfusion Measurement Method

1.2.840.10008.6.1.988

CID 4103

Arterial Input Function Measurement Method

1.2.840.10008.6.1.989

CID 4104

Bolus Arrival Time Derivation Method

1.2.840.10008.6.1.990

CID 4105

Perfusion Analysis Method

1.2.840.10008.6.1.991

CID 4106

Quantitative Method Used for Perfusion and Tracer Kinetic Model

1.2.840.10008.6.1.992

CID 4107

Tracer Kinetic Model Parameter

1.2.840.10008.6.1.993

CID 4108

Perfusion Model Parameter

1.2.840.10008.6.1.994

CID 4109

Model-Independent Dynamic Contrast Analysis Parameter

1.2.840.10008.6.1.995

CID 4110

Tracer Kinetic Modeling Covariate

1.2.840.10008.6.1.996

CID 4111

Contrast Characteristic

1.2.840.10008.6.1.997

CID 7021

Measurement Report Document Title

1.2.840.10008.6.1.998

CID 100

Quantitative Diagnostic Imaging Procedure

1.2.840.10008.6.1.999

CID 7466

PET Region of Interest Measurement

1.2.840.10008.6.1.1000

CID 7467

Gray Level Co-occurrence Matrix Measurement

1.2.840.10008.6.1.1001

CID 7468

Texture Measurement

1.2.840.10008.6.1.1002

CID 6146

Time Point Type

1.2.840.10008.6.1.1003

CID 7469

Generic Intensity and Size Measurement

1.2.840.10008.6.1.1004

CID 6147

Response Criteria

1.2.840.10008.6.1.1005

CID 12020

Fetal Biometry Anatomic Site

1.2.840.10008.6.1.1006

CID 12021

Fetal Long Bone Anatomic Site

1.2.840.10008.6.1.1007

CID 12022

Fetal Cranium Anatomic Site

1.2.840.10008.6.1.1008

CID 12023

Pelvis and Uterus Anatomic Site

1.2.840.10008.6.1.1009

CID 7222

Parametric Map Derivation Image Purpose of Reference

1.2.840.10008.6.1.1010

CID 9000

Physical Quantity Descriptor

1.2.840.10008.6.1.1011

CID 7600

Lymph Node Anatomic Site

1.2.840.10008.6.1.1012

CID 7601

Head and Neck Cancer Anatomic Site

1.2.840.10008.6.1.1013

CID 7701

Fiber Tract In Brainstem

1.2.840.10008.6.1.1014

CID 7702

Projection and Thalamic Fiber

1.2.840.10008.6.1.1015

CID 7703

Association Fiber

1.2.840.10008.6.1.1016

CID 7704

Limbic System Tract

1.2.840.10008.6.1.1017

CID 7705

Commissural Fiber

1.2.840.10008.6.1.1018

CID 7706

Cranial Nerve

1.2.840.10008.6.1.1019

CID 7707

Spinal Cord Fiber

1.2.840.10008.6.1.1020

CID 7710

Tractography Anatomic Site

1.2.840.10008.6.1.1021

CID 4025

Primary Anatomic Structure for Intra-oral Radiography (Supernumerary Dentition - Designation of Teeth)

1.2.840.10008.6.1.1022

CID 4026

Primary Anatomic Structure for Intra-oral and Craniofacial Radiography - Teeth

1.2.840.10008.6.1.1023

CID 9401

IEC61217 Device Position Parameter

1.2.840.10008.6.1.1024

CID 9402

IEC61217 Gantry Position Parameter

1.2.840.10008.6.1.1025

CID 9403

IEC61217 Patient Support Position Parameter

1.2.840.10008.6.1.1026

CID 7035

Actionable Finding Classification

1.2.840.10008.6.1.1027

CID 7036

Image Quality Assessment

1.2.840.10008.6.1.1028

CID 10050

Summary Radiation Exposure Quantity

1.2.840.10008.6.1.1029

CID 4245

Wide Field Ophthalmic Photography Transformation Method

1.2.840.10008.6.1.1030

CID 84

PET Unit

1.2.840.10008.6.1.1031

CID 7300

Implant Material

1.2.840.10008.6.1.1032

CID 7301

Intervention Type

1.2.840.10008.6.1.1033

CID 7302

Implant Template View Orientation

1.2.840.10008.6.1.1034

CID 7303

Implant Template Modified View Orientation

1.2.840.10008.6.1.1035

CID 7304

Implant Target Anatomy

1.2.840.10008.6.1.1036

CID 7305

Implant Planning Landmark

1.2.840.10008.6.1.1037

CID 7306

Human Hip Implant Planning Landmark

1.2.840.10008.6.1.1038

CID 7307

Implant Component Type

1.2.840.10008.6.1.1039

CID 7308

Human Hip Implant Component Type

1.2.840.10008.6.1.1040

CID 7309

Human Trauma Implant Component Type

1.2.840.10008.6.1.1041

CID 7310

Implant Fixation Method

1.2.840.10008.6.1.1042

CID 7445

Device Participating Role

1.2.840.10008.6.1.1043

CID 8101

Container Type

1.2.840.10008.6.1.1044

CID 8102

Container Component Type

1.2.840.10008.6.1.1045

CID 8103

Anatomic Pathology Specimen Type

1.2.840.10008.6.1.1046

CID 8104

Breast Tissue Specimen Type

1.2.840.10008.6.1.1047

CID 8109

Specimen Collection Procedure

1.2.840.10008.6.1.1048

CID 8110

Specimen Sampling Procedure

1.2.840.10008.6.1.1049

CID 8111

Specimen Preparation Procedure

1.2.840.10008.6.1.1050

CID 8112

Specimen Stain

1.2.840.10008.6.1.1051

CID 8113

Specimen Preparation Step

1.2.840.10008.6.1.1052

CID 8114

Specimen Fixative

1.2.840.10008.6.1.1053

CID 8115

Specimen Embedding Media

1.2.840.10008.6.1.1054

CID 10020

Source of Projection X-Ray Dose Information

1.2.840.10008.6.1.1055

CID 10021

Source of CT Dose Information

1.2.840.10008.6.1.1056

CID 10025

Radiation Dose Reference Point

1.2.840.10008.6.1.1057

CID 501

Volumetric View Description

1.2.840.10008.6.1.1058

CID 502

Volumetric View Modifier

1.2.840.10008.6.1.1059

CID 7260

Diffusion Acquisition Value Type

1.2.840.10008.6.1.1060

CID 7261

Diffusion Model Value Type

1.2.840.10008.6.1.1061

CID 7262

Diffusion Tractography Algorithm Family

1.2.840.10008.6.1.1062

CID 7263

Diffusion Tractography Measurement Type

1.2.840.10008.6.​1.​1063

CID 7490

Research Animal Source Registry

1.2.840.10008.6.​1.​1064

CID 231

Yes-No Only

1.2.840.10008.6.​1.​1065

CID 601

Biosafety Level

1.2.840.10008.6.​1.​1066

CID 602

Biosafety Control Reason

1.2.840.10008.6.​1.​1067

CID 7457

Sex - Male Female or Both

1.2.840.10008.6.​1.​1068

CID 603

Animal Room Type

1.2.840.10008.6.​1.​1069

CID 604

Device Reuse

1.2.840.10008.6.​1.​1070

CID 605

Animal Bedding Material

1.2.840.10008.6.​1.​1071

CID 606

Animal Shelter Type

1.2.840.10008.6.​1.​1072

CID 607

Animal Feed Type

1.2.840.10008.6.​1.​1073

CID 608

Animal Feed Source

1.2.840.10008.6.​1.​1074

CID 609

Animal Feeding Method

1.2.840.10008.6.​1.​1075

CID 610

Water Type

1.2.840.10008.6.​1.​1076

CID 611

Anesthesia Category Code Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1077

CID 612

Anesthesia Category Code Type from Anesthesia Quality Initiative

1.2.840.10008.6.​1.​1078

CID 613

Anesthesia Induction Code Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1079

CID 614

Anesthesia Induction Code Type from Anesthesia Quality Initiative

1.2.840.10008.6.​1.​1080

CID 615

Anesthesia Maintenance Code Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1081

CID 616

Anesthesia Maintenance Code Type from Anesthesia Quality Initiative

1.2.840.10008.6.​1.​1082

CID 617

Airway Management Method Code Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1083

CID 618

Airway Management Method Code Type from Anesthesia Quality Initiative

1.2.840.10008.6.​1.​1084

CID 619

Airway Management Sub-Method Code Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1085

CID 620

Airway Management Sub-Method Code Type from Anesthesia Quality Initiative

1.2.840.10008.6.​1.​1086

CID 621

Medication Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1087

CID 622

Medication Type Code Type from Anesthesia Quality Initiative

1.2.840.10008.6.​1.​1088

CID 623

Medication for Small Animal Anesthesia

1.2.840.10008.6.​1.​1089

CID 624

Inhalational Anesthesia Agent for Small Animal Anesthesia

1.2.840.10008.6.​1.​1090

CID 625

Injectable Anesthesia Agent for Small Animal Anesthesia

1.2.840.10008.6.​1.​1091

CID 626

Premedication Agent for Small Animal Anesthesia

1.2.840.10008.6.​1.​1092

CID 627

Neuromuscular Blocking Agent for Small Animal Anesthesia

1.2.840.10008.6.​1.​1093

CID 628

Ancillary Medications for Small Animal Anesthesia

1.2.840.10008.6.​1.​1094

CID 629

Carrier Gases for Small Animal Anesthesia

1.2.840.10008.6.​1.​1095

CID 630

Local Anesthetics for Small Animal Anesthesia

1.2.840.10008.6.​1.​1096

CID 631

Procedure Phase Requiring Anesthesia

1.2.840.10008.6.​1.​1097

CID 632

Surgical Procedure Phase Requiring Anesthesia

1.2.840.10008.6.​1.​1098

CID 633

Phase of Imaging Procedure Requiring Anesthesia (Retired)

Retired

1.2.840.10008.6.​1.​1099

CID 634

Animal Handling Phase

1.2.840.10008.6.​1.​1100

CID 635

Heating Method

1.2.840.10008.6.​1.​1101

CID 636

Temperature Sensor Device Component Type for Small Animal Procedure

1.2.840.10008.6.​1.​1102

CID 637

Exogenous Substance Type

1.2.840.10008.6.​1.​1103

CID 638

Exogenous Substance

1.2.840.10008.6.​1.​1104

CID 639

Tumor Graft Histologic Type

1.2.840.10008.6.​1.​1105

CID 640

Fibril

1.2.840.10008.6.​1.​1106

CID 641

Virus

1.2.840.10008.6.​1.​1107

CID 642

Cytokine

1.2.840.10008.6.​1.​1108

CID 643

Toxin

1.2.840.10008.6.​1.​1109

CID 644

Exogenous Substance Administration Site

1.2.840.10008.6.​1.​1110

CID 645

Exogenous Substance Origin Tissue

1.2.840.10008.6.​1.​1111

CID 646

Preclinical Small Animal Imaging Procedure

1.2.840.10008.6.​1.​1112

CID 647

Position Reference Indicator for Frame of Reference

1.2.840.10008.6.​1.​1113

CID 241

Present-Absent Only

1.2.840.10008.6.​1.​1114

CID 10024

Water Equivalent Diameter Method

1.2.840.10008.6.​1.​1115

CID 7022

Radiotherapy Purpose of Reference

1.2.840.10008.6.​1.​1116

CID 701

Content Assessment Type

1.2.840.10008.6.​1.​1117

CID 702

RT Content Assessment Type

1.2.840.10008.6.​1.​1118

CID 703

Assessment Basis

1.2.840.10008.6.​1.​1119

CID 7449

Reader Specialty

1.2.840.10008.6.​1.​1120

CID 9233

Requested Report Type

1.2.840.10008.6.1.1121

CID 1000

CT Transverse Plane Reference Basis

1.2.840.10008.6.1.1122

CID 1001

Anatomical Reference Basis

1.2.840.10008.6.1.1123

CID 1002

Anatomical Reference Basis - Head

1.2.840.10008.6.1.1124

CID 1003

Anatomical Reference Basis - Spine

1.2.840.10008.6.1.1125

CID 1004

Anatomical Reference Basis - Chest

1.2.840.10008.6.1.1126

CID 1005

Anatomical Reference Basis - Abdomen/Pelvis

1.2.840.10008.6.1.1127

CID 1006

Anatomical Reference Basis - Extremity

1.2.840.10008.6.1.1128

CID 1010

Reference Geometry - Plane

1.2.840.10008.6.1.1129

CID 1011

Reference Geometry - Point

1.2.840.10008.6.1.1130

CID 1015

Patient Alignment Method

1.2.840.10008.6.1.1131

CID 1200

Contraindications For CT Imaging

1.2.840.10008.6.1.1132

CID 7110

Fiducial Category

1.2.840.10008.6.1.1133

CID 7111

Fiducial

1.2.840.10008.6.1.1134

CID 7013

Non-Image Source Instance Purpose of Reference

1.2.840.10008.6.1.1135

CID 7023

RT Process Output

1.2.840.10008.6.1.1136

CID 7024

RT Process Input

1.2.840.10008.6.1.1137

CID 7025

RT Process Input Used

1.2.840.10008.6.1.1138

CID 6300

Prostate Anatomy

1.2.840.10008.6.1.1139

CID 6301

Prostate Sector Anatomy from PI-RADS v2

1.2.840.10008.6.1.1140

CID 6302

Prostate Sector Anatomy from European Concensus 16 Sector (Minimal) Model

1.2.840.10008.6.1.1141

CID 6303

Prostate Sector Anatomy from European Concensus 27 Sector (Optimal) Model

1.2.840.10008.6.1.1142

CID 12301

Measurement Selection Reason

1.2.840.10008.6.1.1143

CID 12302

Echo Finding Observation Type

1.2.840.10008.6.1.1144

CID 12303

Echo Measurement Type

1.2.840.10008.6.1.1145

CID 12304

Echo Measured Property

1.2.840.10008.6.1.1146

CID 12305

Basic Echo Anatomic Site

1.2.840.10008.6.1.1147

CID 12306

Echo Flow Direction

1.2.840.10008.6.1.1148

CID 12307

Cardiac Phase and Time Point

1.2.840.10008.6.1.1149

CID 12300

Core Echo Measurement

1.2.840.10008.6.1.1150

CID 4270

OCT-A Processing Algorithm Family

1.2.840.10008.6.1.1151

CID 4271

En Face Image Type

1.2.840.10008.6.1.1152

CID 4272

OPT Scan Pattern Type

1.2.840.10008.6.1.1153

CID 4273

Retinal Segmentation Surface

1.2.840.10008.6.1.1154

CID 10060

Organ for Radiation Dose Estimate

1.2.840.10008.6.1.1155

CID 10061

Absorbed Radiation Dose Type

1.2.840.10008.6.1.1156

CID 10062

Equivalent Radiation Dose Type

1.2.840.10008.6.1.1157

CID 10063

Radiation Dose Estimate Distribution Representation

1.2.840.10008.6.1.1158

CID 10064

Patient Model Type

1.2.840.10008.6.1.1159

CID 10065

Radiation Transport Model Type

1.2.840.10008.6.1.1160

CID 10066

Attenuator Category

1.2.840.10008.6.1.1161

CID 10067

Radiation Attenuator Material

1.2.840.10008.6.1.1162

CID 10068

Estimate Method Type

1.2.840.10008.6.1.1163

CID 10069

Radiation Dose Estimate Parameter

1.2.840.10008.6.1.1164

CID 10070

Radiation Dose Type

1.2.840.10008.6.1.1165

CID 7270

MR Diffusion Component Semantic

1.2.840.10008.6.1.1166

CID 7271

MR Diffusion Anisotropy Index

1.2.840.10008.6.1.1167

CID 7272

MR Diffusion Model Parameter

1.2.840.10008.6.1.1168

CID 7273

MR Diffusion Model

1.2.840.10008.6.1.1169

CID 7274

MR Diffusion Model Fitting Method

1.2.840.10008.6.1.1170

CID 7275

MR Diffusion Model Specific Method

1.2.840.10008.6.1.1171

CID 7276

MR Diffusion Model Input

1.2.840.10008.6.1.1172

CID 7277

Diffusion Rate Area Over Time Unit

1.2.840.10008.6.1.1173

CID 7039

Pediatric Size Category

1.2.840.10008.6.1.1174

CID 7041

Calcium Scoring Patient Size Category

1.2.840.10008.6.1.1175

CID 10034

Reason for Repeating Acquisition

1.2.840.10008.6.1.1176

CID 800

Protocol Assertion

1.2.840.10008.6.1.1177

CID 7026

Radiotherapeutic Dose Measurement Device

1.2.840.10008.6.1.1178

CID 7014

Export Additional Information Document Title

1.2.840.10008.6.1.1179

CID 7015

Export Delay Reason

1.2.840.10008.6.1.1180

CID 7016

Level of Difficulty

1.2.840.10008.6.1.1181

CID 7017

Category of Teaching Material - Imaging

1.2.840.10008.6.1.1182

CID 7018

Miscellaneous Document Title

1.2.840.10008.6.1.1183

CID 7019

Segmentation Non-Image Source Purpose of Reference

1.2.840.10008.6.1.1184

CID 280

Longitudinal Temporal Event Type

1.2.840.10008.6.1.1185

CID 6401

Non-lesion Object Type - Physical Object

1.2.840.10008.6.1.1186

CID 6402

Non-lesion Object Type - Substance

1.2.840.10008.6.1.1187

CID 6403

Non-lesion Object Type - Tissue

1.2.840.10008.6.1.1188

CID 6404

Chest Non-lesion Object Type - Physical Object

1.2.840.10008.6.1.1189

CID 6405

Chest Non-lesion Object Type - Tissue

1.2.840.10008.6.1.1190

CID 7191

Tissue Segmentation Property Type

1.2.840.10008.6.1.1191

CID 7192

Anatomical Structure Segmentation Property Type

1.2.840.10008.6.1.1192

CID 7193

Physical Object Segmentation Property Type

1.2.840.10008.6.1.1193

CID 7194

Morphologically Abnormal Structure Segmentation Property Type

1.2.840.10008.6.1.1194

CID 7195

Function Segmentation Property Type

1.2.840.10008.6.1.1195

CID 7196

Spatial and Relational Concept Segmentation Property Type

1.2.840.10008.6.1.1196

CID 7197

Body Substance Segmentation Property Type

1.2.840.10008.6.1.1197

CID 7198

Substance Segmentation Property Type

1.2.840.10008.6.1.1198

CID 9303

Interpretation Request Discontinuation Reason

1.2.840.10008.6.1.1199

CID 7475

Gray Level Run Length Based Feature

1.2.840.10008.6.1.1200

CID 7476

Gray Level Size Zone Based Feature

1.2.840.10008.6.1.1201

CID 7060

Encapsulated Document Source Purpose of Reference

1.2.840.10008.6.1.1202

CID 7061

Model Document Title

1.2.840.10008.6.1.1203

CID 7062

Purpose of Reference to Predecessor 3D Model

1.2.840.10008.6.1.1204

CID 7063

Model Scale Unit

1.2.840.10008.6.1.1205

CID 7064

Model Usage

1.2.840.10008.6.1.1206

CID 10071

Radiation Dose Unit

1.2.840.10008.6.1.1207

CID 7112

Radiotherapy Fiducial

1.2.840.10008.6.1.1208

CID 300

Multi-energy Relevant Material

1.2.840.10008.6.1.1209

CID 301

Multi-energy Material Unit

1.2.840.10008.6.1.1210

CID 9500

Dosimetric Objective Type

1.2.840.10008.6.1.1211

CID 9501

Prescription Anatomy Category

1.2.840.10008.6.1.1212

CID 9502

RT Segment Annotation Category

1.2.840.10008.6.1.1213

CID 9503

Radiotherapy Therapeutic Role Category

1.2.840.10008.6.1.1214

CID 9504

RT Geometric Information

1.2.840.10008.6.1.1215

CID 9505

Fixation or Positioning Device

1.2.840.10008.6.1.1216

CID 9506

Brachytherapy Device

1.2.840.10008.6.1.1217

CID 9507

External Body Model

1.2.840.10008.6.1.1218

CID 9508

Non-specific Volume

1.2.840.10008.6.1.1219

CID 9509

Purpose of Reference For RT Physician Intent Input

1.2.840.10008.6.1.1220

CID 9510

Purpose of Reference For RT Treatment Planning Input

1.2.840.10008.6.1.1221

CID 9511

General External Radiotherapy Procedure Technique

1.2.840.10008.6.1.1222

CID 9512

Tomotherapeutic Radiotherapy Procedure Technique

1.2.840.10008.6.1.1223

CID 9513

Fixation Device

1.2.840.10008.6.1.1224

CID 9514

Anatomical Structure For Radiotherapy

1.2.840.10008.6.1.1225

CID 9515

RT Patient Support Device

1.2.840.10008.6.1.1226

CID 9516

Radiotherapy Bolus Device Type

1.2.840.10008.6.1.1227

CID 9517

Radiotherapy Block Device Type

1.2.840.10008.6.1.1228

CID 9518

Radiotherapy Accessory No-slot Holder Device Type

1.2.840.10008.6.1.1229

CID 9519

Radiotherapy Accessory Slot Holder Device Type

1.2.840.10008.6.1.1230

CID 9520

Segmented RT Accessory Device

1.2.840.10008.6.1.1231

CID 9521

Radiotherapy Treatment Energy Unit

1.2.840.10008.6.1.1232

CID 9522

Multi-source Radiotherapy Procedure Technique

1.2.840.10008.6.1.1233

CID 9523

Robotic Radiotherapy Procedure Technique

1.2.840.10008.6.1.1234

CID 9524

Radiotherapy Procedure Technique

1.2.840.10008.6.1.1235

CID 9525

Radiation Therapy Particle

1.2.840.10008.6.1.1236

CID 9526

Ion Therapy Particle

1.2.840.10008.6.1.1237

CID 9527

Teletherapy Isotope

1.2.840.10008.6.1.1238

CID 9528

Brachytherapy Isotope

1.2.840.10008.6.1.1239

CID 9529

Single Dose Dosimetric Objective

1.2.840.10008.6.1.1240

CID 9530

Percentage and Dose Dosimetric Objective

1.2.840.10008.6.1.1241

CID 9531

Volume and Dose Dosimetric Objective

1.2.840.10008.6.1.1242

CID 9532

No-Parameter Dosimetric Objective

1.2.840.10008.6.1.1243

CID 9533

Delivery Time Structure

1.2.840.10008.6.1.1244

CID 9534

Radiotherapy Target

1.2.840.10008.6.1.1245

CID 9535

Radiotherapy Dose Calculation Role

1.2.840.10008.6.1.1246

CID 9536

Radiotherapy Prescribing and Segmenting Person Role

1.2.840.10008.6.1.1247

CID 9537

Effective Dose Calculation Method Category

1.2.840.10008.6.1.1248

CID 9538

Radiation Transport-based Effective Dose Method Modifier

1.2.840.10008.6.1.1249

CID 9539

Fractionation-based Effective Dose Method Modifier

1.2.840.10008.6.1.1250

CID 60

Imaging Agent Administration Adverse Event

1.2.840.10008.6.1.1251

CID 61

Time Relative to Procedure (Retired)

Retired

1.2.840.10008.6.1.1252

CID 62

Imaging Agent Administration Phase Type

1.2.840.10008.6.1.1253

CID 63

Imaging Agent Administration Mode

1.2.840.10008.6.1.1254

CID 64

Imaging Agent Administration Patient State

1.2.840.10008.6.1.1255

CID 65

Imaging Agent Administration Premedication

1.2.840.10008.6.1.1256

CID 66

Imaging Agent Administration Medication

1.2.840.10008.6.1.1257

CID 67

Imaging Agent Administration Completion Status

1.2.840.10008.6.1.1258

CID 68

Imaging Agent Administration Pharmaceutical Presentation Unit

1.2.840.10008.6.1.1259

CID 69

Imaging Agent Administration Consumable

1.2.840.10008.6.1.1260

CID 70

Flush

1.2.840.10008.6.1.1261

CID 71

Imaging Agent Administration Injector Event Type

1.2.840.10008.6.1.1262

CID 72

Imaging Agent Administration Step Type

1.2.840.10008.6.1.1263

CID 73

Bolus Shaping Curve

1.2.840.10008.6.1.1264

CID 74

Imaging Agent Administration Consumable Catheter Type

1.2.840.10008.6.1.1265

CID 75

Low High or Equal

1.2.840.10008.6.1.1266

CID 76

Premedication Type

1.2.840.10008.6.1.1267

CID 245

Laterality with Median

1.2.840.10008.6.1.1268

CID 4029

Dermatology Anatomic Site

1.2.840.10008.6.1.1269

CID 218

Quantitative Image Feature

1.2.840.10008.6.1.1270

CID 7477

Global Shape Descriptor

1.2.840.10008.6.1.1271

CID 7478

Intensity Histogram Feature

1.2.840.10008.6.1.1272

CID 7479

Grey Level Distance Zone Based Feature

1.2.840.10008.6.1.1273

CID 7500

Neighbourhood Grey Tone Difference Based Feature

1.2.840.10008.6.1.1274

CID 7501

Neighbouring Grey Level Dependence Based Feature

1.2.840.10008.6.1.1275

CID 4242

Cornea Measurement Method Descriptor

1.2.840.10008.6.1.1276

CID 7027

Segmented Radiotherapeutic Dose Measurement Device

1.2.840.10008.6.1.1277

CID 6098

Clinical Course of Disease

1.2.840.10008.6.1.1278

CID 6099

Racial Group

1.2.840.10008.6.1.1279

CID 246

Relative Laterality

1.2.840.10008.6.1.1280

CID 7168

Brain Lesion Segmentation Type With Necrosis

1.2.840.10008.6.1.1281

CID 7169

Brain Lesion Segmentation Type Without Necrosis

1.2.840.10008.6.1.1282

CID 32

Non-Acquisition Modality

1.2.840.10008.6.1.1283

CID 33

Modality

1.2.840.10008.6.1.1284

CID 247

Laterality Left-Right Only

1.2.840.10008.6.1.1285

CID 210

Qualitative Evaluation Modifier Type

1.2.840.10008.6.1.1286

CID 211

Qualitative Evaluation Modifier Value

1.2.840.10008.6.1.1287

CID 212

Generic Anatomic Location Modifier

1.2.840.10008.6.1.1288

CID 9541

Beam Limiting Device Type

1.2.840.10008.6.1.1289

CID 9542

Compensator Device Type

1.2.840.10008.6.1.1290

CID 9543

Radiotherapy Treatment Machine Mode

1.2.840.10008.6.1.1291

CID 9544

Radiotherapy Distance Reference Location

1.2.840.10008.6.1.1292

CID 9545

Fixed Beam Limiting Device Type

1.2.840.10008.6.1.1293

CID 9546

Radiotherapy Wedge Type

1.2.840.10008.6.1.1294

CID 9547

RT Beam Limiting Device Orientation Label

1.2.840.10008.6.1.1295

CID 9548

General Accessory Device Type

1.2.840.10008.6.1.1296

CID 9549

Radiation Generation Mode Type

1.2.840.10008.6.1.1297

CID 9550

C-Arm Photon-Electron Delivery Rate Unit

1.2.840.10008.6.1.1298

CID 9551

Treatment Delivery Device Type

1.2.840.10008.6.1.1299

CID 9552

C-Arm Photon-Electron Dosimeter Unit

1.2.840.10008.6.1.1300

CID 9553

Treatment Point

1.2.840.10008.6.1.1301

CID 9554

Equipment Reference Point

1.2.840.10008.6.1.1302

CID 9555

Radiotherapy Treatment Planning Person Role

1.2.840.10008.6.1.1303

CID 7070

Real Time Video Rendition Title

1.2.840.10008.6.1.1304

CID 219

Geometry Graphical Representation

1.2.840.10008.6.1.1305

CID 217

Visual Explanation

1.2.840.10008.6.​1.​1306

CID 6304

Prostate Sector Anatomy from PI-RADS v2.1

1.2.840.10008.6.​1.​1307

CID 9556

Radiotherapy Robotic Node Set

1.2.840.10008.6.​1.​1308

CID 9557

Tomotherapeutic Dosimeter Unit

1.2.840.10008.6.​1.​1309

CID 9558

Tomotherapeutic Dose Rate Unit

1.2.840.10008.6.​1.​1310

CID 9559

Robotic Delivery Device Dosimeter Unit

1.2.840.10008.6.​1.​1311

CID 9560

Robotic Delivery Device Dose Rate Unit

1.2.840.10008.6.​1.​1312

CID 8134

Anatomic Structure

1.2.840.10008.6.​1.​1313

CID 6148

Mediastinum Finding or Feature

1.2.840.10008.6.​1.​1314

CID 6149

Mediastinum Anatomy

1.2.840.10008.6.​1.1315

CID 12100

Vascular Ultrasound Report Document Title

1.2.840.10008.6.​1.1316

CID 12130

Organ Part (Non-Lateralized)

1.2.840.10008.6.​1.1317

CID 12131

Organ Part (Lateralized)

1.2.840.10008.6.1.1318

CID 9561

Treatment Termination Reason

1.2.840.10008.6.1.1319

CID 9562

Radiotherapy Treatment Delivery Person Role

1.2.840.10008.6.1.1320

CID 9563

Radiotherapy Interlock Resolution

1.2.840.10008.6.1.1321

CID 9564

Treatment Session Confirmation Assertion

1.2.840.10008.6.1.1322

CID 9565

Treatment Tolerance Violation Cause

1.2.840.10008.6.1.1323

CID 9566

Clinical Tolerance Violation Type

1.2.840.10008.6.1.1324

CID 9567

Machine Tolerance Violation Type

1.2.840.10008.6.1.1325

CID 9568

Radiotherapy Treatment Interlock

1.2.840.10008.6.1.1326

CID 9569

Isocentric Patient Support Position Parameter

1.2.840.10008.6.1.1327

CID 9570

RT Overridden Treatment Parameter

1.2.840.10008.6.1.1328

CID 3030

EEG Lead

1.2.840.10008.6.1.1329

CID 3031

Lead Location Near or in Muscle

1.2.840.10008.6.1.1330

CID 3032

Lead Location Near Peripheral Nerve

1.2.840.10008.6.1.1331

CID 3033

EOG Lead

1.2.840.10008.6.1.1332

CID 3034

Body Position Channel

1.2.840.10008.6.1.1333

CID 3035

EEG Annotation – Neurophysiologic Enumeration

1.2.840.10008.6.1.1334

CID 3036

EMG Annotation – Neurophysiological Enumeration

1.2.840.10008.6.1.1335

CID 3037

EOG Annotation – Neurophysiological Enumeration

1.2.840.10008.6.1.1336

CID 3038

Pattern Event

1.2.840.10008.6.1.1337

CID 3039

Device-related and Environment-related Event

1.2.840.10008.6.1.1338

CID 3040

EEG Annotation - Neurological Monitoring Measurement

1.2.840.10008.6.​1.1339

CID 12024

OB-GYN Ultrasound Report Document Title

1.2.840.10008.6.​1.1340

CID 7230

Automation of Measurement

1.2.840.10008.6.​1.1341

CID 12025

OB-GYN Ultrasound Beam Path

1.2.840.10008.6.​1.1342

CID 7550

Angle Measurement

1.2.840.10008.6.​1.1343

CID 7551

Generic Purpose of Reference to Images and Coordinates in Measurement

1.2.840.10008.6.​1.1344

CID 7552

Generic Purpose of Reference to Images in Measurement

1.2.840.10008.6.​1.1345

CID 7553

Generic Purpose of Reference to Coordinates in Measurement

1.2.840.10008.6.​1.1346

CID 4401

Fitzpatrick Skin Type

1.2.840.10008.6.​1.1347

CID 4402

History of Malignant Melanoma

1.2.840.10008.6.​1.1348

CID 4403

History of Melanoma in Situ

1.2.840.10008.6.​1.1349

CID 4404

History of Non-Melanoma Skin Cancer

1.2.840.10008.6.​1.1350

CID 4405

Skin Disorder

1.2.840.10008.6.​1.1351

CID 4406

Patient Reported Lesion Characteristic

1.2.840.10008.6.​1.1352

CID 4407

Lesion Palpation Finding

1.2.840.10008.6.​1.1353

CID 4408

Lesion Visual Finding

1.2.840.10008.6.​1.1354

CID 4409

Skin Procedure

1.2.840.10008.6.​1.1355

CID 12125

Abdominopelvic Vessel

1.2.840.10008.6.​1.1356

CID 43

Numeric Value Failure Qualifier

1.2.840.10008.6.​1.1357

CID 44

Numeric Value Unknown Qualifier

1.2.840.10008.6.​1.​1358

CID 7170

Couinaud Liver Segment

1.2.840.10008.6.​1.​1359

CID 7171

Liver Segmentation Type

1.2.840.10008.6.​1.​1360

CID 1201

Contraindications For XA Imaging

1.2.840.10008.6.​1.​1361

CID 3041

Neurophysiologic Stimulation Mode

1.2.840.10008.6.​1.​1362

CID 10072

Reported Value Type

1.2.840.10008.6.​1.​1363

CID 10073

Value Timing

1.2.840.10008.6.​1.​1364

CID 10074

RDSR Frame of Reference Origin

1.2.840.10008.6.​1.​1365

CID 8135

Microscopy Annotation Property Type

1.2.840.10008.6.​1.​1366

CID 8136

Microscopy Measurement Type

1.2.840.10008.6.​1.​1367

CID 6310

Prostate Reporting System

1.2.840.10008.6.​1.​1368

CID 6311

MR Signal Intensity

1.2.840.10008.6.​1.​1369

CID 6312

Cross-sectional Scan Plane Orientation

1.2.840.10008.6.​1.​1370

CID 6313

History of Prostate Disease

1.2.840.10008.6.​1.​1371

CID 6314

Prostate MRI Study Quality Finding

1.2.840.10008.6.​1.​1372

CID 6315

Prostate MRI Series Quality Finding

1.2.840.10008.6.​1.​1373

CID 6316

MR Imaging Artifact

1.2.840.10008.6.​1.​1374

CID 6317

Prostate DCE MRI Quality Finding

1.2.840.10008.6.​1.​1375

CID 6318

Prostate DWI MRI Quality Finding

1.2.840.10008.6.​1.​1376

CID 6319

Abdominal Intervention Type

1.2.840.10008.6.​1.​1377

CID 6320

Abdominopelvic Intervention

1.2.840.10008.6.​1.​1378

CID 6321

Prostate Cancer Diagnostic Procedure

1.2.840.10008.6.​1.​1379

CID 6322

Prostate Cancer Family History

1.2.840.10008.6.​1.​1380

CID 6323

Prostate Cancer Therapy

1.2.840.10008.6.​1.​1381

CID 6324

Prostate MRI Assessment

1.2.840.10008.6.​1.​1382

CID 6325

Overall Assessment from PI-RADS®

1.2.840.10008.6.​1.​1383

CID 6326

Image Quality Control Standard

1.2.840.10008.6.​1.​1384

CID 6327

Prostate Imaging Indication

1.2.840.10008.6.​1.​1385

CID 6328

PI-RADS® v2 Lesion Assessment Category

1.2.840.10008.6.​1.​1386

CID 6329

PI-RADS® v2 T2WI PZ Lesion Assessment Category

1.2.840.10008.6.​1.​1387

CID 6330

PI-RADS® v2 T2WI TZ Lesion Assessment Category

1.2.840.10008.6.​1.​1388

CID 6331

PI-RADS® v2 DWI Lesion Assessment Category

1.2.840.10008.6.​1.​1389

CID 6332

PI-RADS® v2 DCE Lesion Assessment Category

1.2.840.10008.6.​1.​1390

CID 6333

mpMRI Assessment Type

1.2.840.10008.6.​1.​1391

CID 6334

mpMRI Assessment Type from PI-RADS®

1.2.840.10008.6.​1.​1392

CID 6335

mpMRI Assessment Value

1.2.840.10008.6.​1.​1393

CID 6336

MRI Abnormality

1.2.840.10008.6.​1.​1394

CID 6337

mpMRI Prostate Abnormality from PI-RADS®

1.2.840.10008.6.​1.​1395

CID 6338

mpMRI Benign Prostate Abnormality from PI-RADS®

1.2.840.10008.6.​1.​1396

CID 6339

MRI Shape Characteristic

1.2.840.10008.6.​1.​1397

CID 6340

Prostate MRI Shape Characteristic from PI-RADS®

1.2.840.10008.6.​1.​1398

CID 6341

MRI Margin Characteristic

1.2.840.10008.6.​1.​1399

CID 6342

Prostate MRI Margin Characteristic from PI-RADS®

1.2.840.10008.6.​1.​1400

CID 6343

MRI Signal Characteristic

1.2.840.10008.6.​1.​1401

CID 6344

Prostate MRI Signal Characteristic from PI-RADS®

1.2.840.10008.6.​1.​1402

CID 6345

MRI Enhancement Pattern

1.2.840.10008.6.​1.​1403

CID 6346

Prostate MRI Enhancement Pattern from PI-RADS®

1.2.840.10008.6.​1.​1404

CID 6347

Prostate MRI Extra-prostatic Finding

1.2.840.10008.6.​1.​1405

CID 6348

Prostate MRI Assessment of Extra-prostatic Anatomic Site

1.2.840.10008.6.​1.​1406

CID 6349

MR Coil Type

1.2.840.10008.6.​1.​1407

CID 6350

Endorectal Coil Fill Substance

1.2.840.10008.6.​1.​1408

CID 6351

Prostate Relational Measurement

1.2.840.10008.6.​1.​1409

CID 6352

Prostate Cancer Diagnostic Blood Lab Measurement

1.2.840.10008.6.​1.​1410

CID 6353

Prostate Imaging Types of Quality Control Standard

1.2.840.10008.6.​1.​1411

CID 12308

Ultrasound Shear Wave Measurement

1.2.840.10008.6.​1.​1412

CID 3780

Left Ventricle Myocardial Wall 16 Segment Model (Retired)

Retired

1.2.840.10008.6.​1.​1413

CID 3781

Left Ventricle Myocardial Wall 18 Segment Model

1.2.840.10008.6.​1.​1414

CID 3782

Left Ventricle Basal Wall 6 Segments

1.2.840.10008.6.​1.​1415

CID 3783

Left Ventricle Midlevel Wall 6 Segments

1.2.840.10008.6.​1.​1416

CID 3784

Left Ventricle Apical Wall 4 Segments

1.2.840.10008.6.​1.​1417

CID 3785

Left Ventricle Apical Wall 6 Segments

1.2.840.10008.6.1.1418

CID 9571

Patient Treatment Preparation Method

1.2.840.10008.6.1.1419

CID 9572

Patient Shielding Device

1.2.840.10008.6.1.1420

CID 9573

Patient Treatment Preparation Device

1.2.840.10008.6.1.1421

CID 9574

Patient Position Displacement Reference Point

1.2.840.10008.6.1.1422

CID 9575

Patient Alignment Device

1.2.840.10008.6.1.1423

CID 9576

Reasons for RT Radiation Treatment Omission

1.2.840.10008.6.1.1424

CID 9577

Patient Treatment Preparation Procedure

1.2.840.10008.6.1.1425

CID 9578

Motion Management Setup Device

1.2.840.10008.6.1.1426

CID 12309

Core Echo Strain Measurement

1.2.840.10008.6.1.1427

CID 12310

Myocardial Strain Method

1.2.840.10008.6.1.1428

CID 12311

Echo Measured Strain Property

1.2.840.10008.6.1.1429

CID 3020

Assessment from CAD-RADS™

1.2.840.10008.6.1.1430

CID 3021

CAD-RADS™ Stenosis Assessment Modifier

1.2.840.10008.6.1.1431

CID 3022

CAD-RADS™ Assessment Modifier

1.2.840.10008.6.1.1432

CID 9579

RT Segment Material

1.2.840.10008.6.1.1433

CID 7602

Vertebral Anatomic Structure

1.2.840.10008.6.1.1434

CID 7603

Vertebra

1.2.840.10008.6.1.1435

CID 7604

Intervertebral Disc

1.2.840.10008.6.1.1436

CID 101

Imaging Procedure

1.2.840.10008.6.1.1437

CID 103

NICIP Short Code Imaging Procedure

1.2.840.10008.6.1.1438

CID 104

NICIP SNOMED Imaging Procedure

1.2.840.10008.6.1.1439

CID 105

ICD-10-PCS Imaging Procedure

1.2.840.10008.6.1.1440

CID 106

ICD-10-PCS Nuclear Medicine Procedure

1.2.840.10008.6.1.1441

CID 107

ICD-10-PCS Radiation Therapy Procedure

1.2.840.10008.6.1.1442

CID 9580

RT Segmentation Property Category

1.2.840.10008.6.1.1443

CID 9581

Radiotherapy Registration Mark

1.2.840.10008.6.1.1444

CID 9582

Radiotherapy Dose Region

1.2.840.10008.6.​1.1445

CID 7199

Anatomically Localized Lesion Segmentation Type

1.2.840.10008.6.​1.1446

CID 7031

Reason for Removal from Operational Use

1.2.840.10008.6.​1.1447

CID 12320

General Ultrasound Report Document Title

1.2.840.10008.6.​1.1448

CID 12321

Elastography Site

1.2.840.10008.6.​1.1449

CID 12322

Elastography Measurement Site

1.2.840.10008.6.​1.1450

CID 12323

Ultrasound Relevant Patient Condition

1.2.840.10008.6.​1.1451

CID 12324

Shear Wave Detection Method

1.2.840.10008.6.​1.1452

CID 12325

Liver Ultrasound Study Indication

1.2.840.10008.6.​1.1453

CID 3042

Analog Waveform Filter

1.2.840.10008.6.​1.1454

CID 3043

Digital Waveform Filter

1.2.840.10008.6.​1.1455

CID 3044

Waveform Filter Lookup Table Input Frequency Unit

1.2.840.10008.6.​1.1456

CID 3045

Waveform Filter Lookup Table Output Magnitude Unit

1.2.840.10008.6.​1.1457

CID 272

Specific Observation Subject Class

1.2.840.10008.6.​1.1458

CID 9540

Movable Beam Limiting Device Type

1.2.840.10008.6.​1.1459

CID 9260

Radiotherapy Acquisition WorkItem Subtasks

1.2.840.10008.6.​1.1460

CID 9261

Patient Position Acquisition Radiation Source Locations

1.2.840.10008.6.​1.1461

CID 9262

Energy Derivation Types

1.2.840.10008.6.​1.1462

CID 9263

KV Imaging Acquisition Techniques

1.2.840.10008.6.​1.1463

CID 9264

MV Imaging Acquisition Techniques

1.2.840.10008.6.​1.1464

CID 9265

Patient Position Acquisition - Projection Techniques

1.2.840.10008.6.​1.1465

CID 9266

Patient Position Acquisition – CT Techniques

1.2.840.10008.6.​1.1466

CID 9267

Patient Positioning Related Object Purposes

1.2.840.10008.6.​1.1467

CID 9268

Patient Position Acquisition Devices

1.2.840.10008.6.​1.1468

CID 9269

RT Radiation Meterset Units

1.2.840.10008.6.​1.1469

CID 9270

Acquisition Initiation Types

1.2.840.10008.6.​1.1470

CID 9271

RT Image Patient Position Acquisition Devices

1.2.840.10008.6.1.1471

CID 11001

Photoacoustic Illumination Method

1.2.840.10008.6.1.1472

CID 11002

Acoustic Coupling Medium

1.2.840.10008.6.1.1473

CID 11003

Ultrasound Transducer Technology

1.2.840.10008.6.1.1474

CID 11004

Speed of Sound Correction Mechanisms

1.2.840.10008.6.1.1475

CID 11005

Photoacoustic Reconstruction Algorithm Family

1.2.840.10008.6.1.1476

CID 11006

Photoacoustic Imaged Property

1.2.840.10008.6.1.1477

CID 10005

X-Ray Radiation Dose Procedure Type Reported

1.2.840.10008.6.1.1478

CID 4410

Topical Treatment

1.2.840.10008.6.1.1479

CID 4411

Lesion Color

1.2.840.10008.6.1.1480

CID 4412

Specimen Stain for Confocal Microscopy

1.2.840.10008.6.1.1481

CID 9272

RT ROI Image Acquisition Context

1.2.840.10008.6.1.1482

CID 6170

Lobe of Lung

1.2.840.10008.6.1.1483

CID 6171

Zone of Lung

1.2.840.10008.6.1.1484

CID 3046

Sleep Stage

1.2.840.10008.6.1.1485

CID 9273

Patient Position Acquisition – MR Techniques

1.2.840.10008.6.1.1486

CID 9583

RT Plan Radiotherapy Procedure Technique

1.2.840.10008.6.1.1487

CID 3047

Waveform Annotation Classification

1.2.840.10008.6.1.1488

CID 3048

Waveform Annotations Document Title

1.2.840.10008.6.1.1489

CID 3049

EEG Procedure

1.2.840.10008.6.1.1490

CID 3050

Patient Consciousness

1.2.840.10008.6.1.1491

CID 12010

Follicle Type

1.2.840.10008.6.1.1492

CID 7163

Breast Segmentation Types

1.2.840.10008.6.1.1493

CID 3779

Implanted Device

1.2.840.10008.6.1.1494

CID 281

Similarity Measure

1.2.840.10008.6.1.1495

CID 34

Waveform Acquisition Modality

1.2.840.10008.6.1.1496

CID 4274

En Face Processing Algorithm Family

1.2.840.10008.6.1.1497

CID 4275

Anterior Eye Segmentation Surface

1.2.840.10008.6.1.1498

CID 12312

Fetal Echocardiography Image View

1.2.840.10008.6.1.1499

CID 12313

Cardiac Ultrasound Fetal Arrhythmia Measurements

1.2.840.10008.6.1.1500

CID 12314

Common Fetal Echocardiography Measurements


Note

For some Context Group UIDs, no Context Group Name or Identifier is specified; these are "placeholders" that are not assigned but will not be reused.

Table A-4 lists the UID values that are registered for document templates.

Table A-4. Template UID Values

UID Value

UID Name

UID Type

Part

1.2.840.10008.9.1

Imaging Report

Document TemplateID

PS3.20

1.2.840.10008.9.2

Clinical Information

Section TemplateID

PS3.20

1.2.840.10008.9.3

Imaging Procedure Description

Section TemplateID

PS3.20

1.2.840.10008.9.4

Comparison Study

Section TemplateID

PS3.20

1.2.840.10008.9.5

Impression

Section TemplateID

PS3.20

1.2.840.10008.9.6

Addendum

Section TemplateID

PS3.20

1.2.840.10008.9.7

Request

Section TemplateID

PS3.20

1.2.840.10008.9.8

Radiation Exposure and Protection Information

Section TemplateID

PS3.20

1.2.840.10008.9.9

Fetus Findings

Section TemplateID

PS3.20

1.2.840.10008.9.10

Labeled Subsection

Section TemplateID

PS3.20

1.2.840.10008.9.11

Communication of Actionable Findings

Section TemplateID

PS3.20

1.2.840.10008.9.12

Recommendation

Section TemplateID

PS3.20

1.2.840.10008.9.13

Procedural Medication

Entry TemplateID

PS3.20

1.2.840.10008.9.14

Procedure Technique

Entry TemplateID

PS3.20

1.2.840.10008.9.15

Image Quality

Entry TemplateID

PS3.20

1.2.840.10008.9.16

Study Act

Entry TemplateID

PS3.20

1.2.840.10008.9.17

Series Act

Entry TemplateID

PS3.20

1.2.840.10008.9.18

SOP Instance Observation

Entry TemplateID

PS3.20

1.2.840.10008.9.19

Section Text

Element Set TemplateID

PS3.20

1.2.840.10008.9.20

General Header

Element Set TemplateID

PS3.20

1.2.840.10008.9.21

Imaging Header

Element Set TemplateID

PS3.20

1.2.840.10008.9.22

Parent Document

Element Set TemplateID

PS3.20

1.2.840.10008.9.23

General Section Entries

Element Set TemplateID

PS3.20

1.2.840.10008.9.24

Imaging Addendum Report

Document TemplateID

PS3.20


DICOM PS3.6 2024d - Data Dictionary