DICOM PS3.3 2024d - Information Object Definitions |
---|
Table C.4-12. Imaging Service Request Module Attributes
Name of the physician who requested the Imaging Service Request. |
||
Identification of the physician who requested the Imaging Service Request. |
||
>Include Table 10-1 “Person Identification Macro Attributes” |
||
Name of the Patient's referring physician for this Imaging Service Request. |
||
>Include Table 10-1 “Person Identification Macro Attributes” |
||
Institutional department, unit or service where the request initiated. See Note 3. |
||
Institutional department, unit or service where the request initiated. Equivalent to HL7 v2.x ORC-17. See Note 3. |
||
A departmental Information System generated number that identifies the Imaging Service Request. |
||
Identifier of the Assigning Authority that issued the Accession Number. |
||
>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
Date on which the Imaging Service Request was issued by the requester. |
||
Time at which the Imaging Service Request was issued by the requester. |
||
The order number assigned to the Imaging Service Request by the party placing the order. |
||
Identifier of the Assigning Authority that issued the Placer Order Number. |
||
>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
The order number assigned to the Imaging Service Request by the party filling the order. |
||
Identifier of the Assigning Authority that issued the Filler Order Number. |
||
>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
The person who entered the Imaging Service Request into an Information System. |
||
The location at which the Imaging Service Request was entered. |
||
Telephone Number at which additional information can be retrieved. |
||
The telecommunication contact information, including telephone, email, or other telecom addresses, at which additional information about the order can be retrieved. Note
|
||
Identification number of the Visit as assigned by the healthcare provider |
||
Identifier of the Assigning Authority that issued the Admission ID. |
||
>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
Reason(s) for this visit by the patient to the facility or provider. |
||
Coded reason(s) for this visit by the patient to the facility or provider. |
||
Placer Order Number / Imaging Service Request (0040,2016) and Filler Order Number / Imaging Service Request (0040,2017) are intended to convey the corresponding order numbers as defined in HL7, in the case where interoperability with an HL7 environment is the objective.
Attributes (0040,2001), (0040,2006) and (0040,2007) were previously defined in DICOM. They are now retired (see PS3.3-1998 ).
Both Requesting Service (0032,1033) and Requesting Service Code Sequence (0032,1034) are defined in this table; the latter is preferred, but the former may be copied from an HL7 message whether or not there is also the ability to map it to a coded form (e.g., with only ORC-17 component 1 valued).
DICOM PS3.3 2024d - Information Object Definitions |
---|