DICOM PS3.3 2024d - Information Object Definitions |
---|
Table C.17-2 specifies the Attributes of an SR Document Instance. These Attributes identify the SR Document and provide context for the entire document.
Table C.17-2. SR Document General Module Attributes
Indicates whether this SR Document is intended to be regarded as a preliminary or final report. Enumerated Values: |
|||
The estimated degree of completeness of this SR Document. See Section C.17.2.7. |
|||
Indicates whether this SR Document is Verified. Enumerated Values: A value of "VERIFIED" shall be used only when the value of Completion Flag (0040,A491) is "COMPLETE". |
|||
The person or persons authorized to verify documents of this type and accept responsibility for the content of this document. |
|||
The person authorized by the Verifying Organization (0040,A027) to verify documents of this type and who accepts responsibility for the content of this document. |
|||
Organization to which the Verifying Observer Name (0040,A075) is accountable in the current interpretation procedure. |
|||
Date and Time of verification by the Verifying Observer Name (0040,A075). |
|||
The person or device that created the clinical content of this document. This Attribute sets the default Observer Context for the root of the Content Tree. |
|||
>Include Table C.17-3b “Identified Person or Device Macro Attributes” |
|||
Persons or devices related to the clinical content of this document. |
|||
Participant's role with respect to the clinical content of this document. See Section C.17.2.5. Defined Terms: |
|||
DateTime of participation with respect to the clinical content of this document. |
|||
>Include Table C.17-3b “Identified Person or Device Macro Attributes” |
|||
Custodial organization for this SR Document Instance. Represents the organization from which the document originates and that is in charge of maintaining the document, i.e., the steward of the original source document. NoteThis may or may not be identical to the Institution identified in the General Equipment Module. |
|||
The department, unit or service that is responsible for the management of this Instance. See Section C.34.2.3. |
|||
References to SOP Instances (e.g., prior or preliminary reports) whose content has been wholly or partially included in this document with or without modification. One or more Items shall be included in this Sequence. Required if this document includes content from other documents. |
|||
>Include Table C.17-3 “Hierarchical SOP Instance Reference Macro Attributes” |
Purpose of Reference Code Sequence in the Hierarchical SOP Instance Reference Macro DCID 7009 “Purpose of Reference to Predecessor Report”. |
||
Duplicates of this document, stored with different SOP Instance UIDs. One or more Items shall be included in this Sequence. Required if this document is stored with different SOP Instance UIDs in one or more other Studies. See Section C.17.2.2 for further explanation. |
|||
>Include Table C.17-3 “Hierarchical SOP Instance Reference Macro Attributes” |
|||
Identifies Requested Procedures that are being fulfilled (completely or partially) by creation of this Document. One or more Items shall be included in this Sequence. Required if this Document fulfills at least one Requested Procedure. May be present otherwise. |
|||
>Include Table C.17-3c “Referenced Request Macro Attributes” |
|||
A Sequence that conveys the codes of the performed procedures pertaining to this SOP Instance. Zero or more Items shall be included in this Sequence. |
|||
Full set of Composite SOP Instances, of which the creator is aware, which were created to satisfy the current Requested Procedure(s) for which this SR Document is generated or that are referenced in the Content Tree. One or more Items shall be included in this Sequence. Required if the creator is aware of Composite Objects acquired in order to satisfy the Requested Procedure(s) for which the SR Document is or if Instances are referenced in the Content Tree. May be present otherwise. See Section C.17.2.3 for further explanation. |
|||
>Include Table C.17-3 “Hierarchical SOP Instance Reference Macro Attributes” |
|||
Other Composite SOP Instances that are considered to be pertinent evidence by the creator of this SR Document. This evidence must have been acquired in order to satisfy Requested Procedures other than the one(s) for which this SR Document is generated. One or more Items shall be included in this Sequence. Required if pertinent evidence from other Requested Procedures needs to be recorded. See Section C.17.2.3 for further explanation. |
|||
>Include Table C.17-3 “Hierarchical SOP Instance Reference Macro Attributes” |
|||
Sequence specifying SOP Instances significantly related to the current SOP Instance, but which are not referenced in the Current Requested Procedure Evidence Sequence (0040,A375), Pertinent Other Evidence Sequence (0040,A385), Predecessor Documents Sequence (0040,A360) or Identical Documents Sequence (0040,A525). Such referenced Instances may include equivalent documents or renderings of this document. One or more Items shall be included in this Sequence. Required if the identity of a CDA Document equivalent to the current SOP Instance is known at the time of creation of this SOP Instance (see Section C.17.2.6). May be present otherwise. |
|||
>Include Table 10-11 “SOP Instance Reference Macro Attributes” |
|||
Code describing the purpose of the reference to the Instance(s). |
|||
Table C.17-3 specifies the Attributes of the Hierarchical SOP Instance Reference Macro, which reference a list of SOP Instances.
Table C.17-3. Hierarchical SOP Instance Reference Macro Attributes
Sequence of Items where each Item includes the Attributes of a Series containing referenced Composite Object(s). |
|||
>Include Table C.17-3a “Hierarchical Series Reference Macro Attributes” |
Table C.17-3a specifies the Attributes that reference a Series of SOP Instances.
Table C.17-3a. Hierarchical Series Reference Macro Attributes
Unique identifier of a Series that is part of this Study and contains the referenced Composite Object(s). |
|||
Title of the DICOM Application Entity where the Composite Object(s) may be retrieved on the network. |
|||
Unique identifier of the system where the Composite Object(s) may be retrieved on the network. |
|||
The user or implementation specific human readable identifier that identifies the Storage Media on which the Composite Object (s) reside. |
|||
Uniquely identifies the Storage Media on which the Composite Object(s) reside. |
|||
References to Composite Object SOP Class/SOP Instance pairs that are part of the Study defined by Study Instance UID and the Series defined by Series Instance UID (0020,000E). |
|||
>Include Table 10-11 “SOP Instance Reference Macro Attributes” |
|||
Sequence of references to Digital Signatures in the referenced SOP Instance. |
|||
The Unique Identifier of a Digital Signature held in the referenced SOP Instance. |
|||
The Signature Value identified by the Digital Signature UID within the Referenced SOP Instance UID. |
|||
A MAC Calculation from data in the referenced SOP Instance that can be used as a data integrity check. |
|||
The Transfer Syntax UID used to encode the values of the Data Elements included in the MAC calculation. When computing the MAC, only Transfer Syntaxes that explicitly include the VR and use Little Endian encoding shall be used. Note
|
|||
The algorithm used in generating the MAC. For Defined Terms, see Table C.12.1.1.3.1.2-1, “Defined Terms for MAC Algorithm (0400,0015)”. |
|||
A list of Data Element Tags in the order they appear at the top level of the referenced SOP Instance that identify the Data Elements used in creating the MAC. See Section C.12.1.1.3.1.1. |
|||
The MAC generated as described in Section C.12.1.1.3, but unencrypted and without inclusion of fields from the Digital Signatures Sequence. See Section C.12.1.1.3.1.2. |
DICOM PS3.3 2024d - Information Object Definitions |
---|