DICOM PS3.3 2024d - Information Object Definitions |
---|
Table 10-9. Request Attributes Macro Attributes
Identifier that identifies the Requested Procedure in the Imaging Service Request. Required if procedure was scheduled. May be present otherwise. NoteThe condition is to allow the contents of this Macro to be present (e.g., to convey the reason for the procedure, such as whether a mammogram is for screening or diagnostic purposes) even when the procedure was not formally scheduled and a value for this identifier is unknown, rather than making up a dummy value. |
|||
A departmental Information System generated number that identifies the Imaging Service Request. |
|||
Identifier of the Assigning Authority that issued the Accession Number. |
|||
>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
|||
The unique identifier for the Study provided for this Requested Procedure. |
|||
Uniquely identifies the Studies associated with this SOP Instance. One or more Items are permitted in this Sequence. See Section 10.6.1. |
|||
>Include Table 10-11 “SOP Instance Reference Macro Attributes” |
|||
Institution-generated administrative description or classification of Requested Procedure. |
|||
A Sequence that conveys the Procedure Type of the requested procedure. |
|||
Identifier that identifies the Scheduled Procedure Step. Required if procedure was scheduled. NoteThe condition is to allow the contents of this Macro to be present (e.g., to convey the reason for the procedure, such as whether a mammogram is for screening or diagnostic purposes) even when the procedure step was not formally scheduled and a value for this identifier is unknown, rather than making up a dummy value. |
|||
Institution-generated description or classification of the Scheduled Procedure Step to be performed. |
|||
Sequence describing the Scheduled Protocol following a specific coding scheme. One or more Items are permitted in this Sequence. |
|||
Sequence that specifies the context for the Scheduled Protocol Code Sequence (0040,0008) Item. One or more Items are permitted in this Sequence. |
|||
Sequence that specifies modifiers for a Protocol Context Content Item. One or more Items are permitted in this Sequence. See Section C.4.10.1. |
|||
>>>Include Table 10-2 “Content Item Macro Attributes” |
Since Referenced Study Sequence (0008,1110) is Type 2 or 3 in each usage, the Attribute may be zero length or omitted, respectively.
If Referenced Study Sequence (0008,1110) is present with an Item, the SOP Class UID of the Detached Study Management SOP Class (Retired) may be used in Referenced SOP Class UID (0008,1150).
DICOM PS3.3 2024d - Information Object Definitions |
---|