DICOM PS3.3 2024d - Information Object Definitions |
---|
The following standards contain provisions that, through reference in this text, constitute provisions of this Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this Standard are encouraged to investigate the possibilities of applying the most recent editions of the standards indicated below.
[ISO/IEC Directives, Part 2] 2016/05. 7.0. Rules for the structure and drafting of International Standards. http://www.iec.ch/members_experts/refdocs/iec/isoiecdir-2%7Bed7.0%7Den.pdf .
[ISO 7498-1] 1994. Information Processing Systems - Open Systems Interconnection - Basic Reference Model.
[ISO 7498-2] 1989. Information processing systems - Open Systems Interconnection - Basic reference Model - Part 2: Security Architecture.
[ISO/TR 8509] Information Processing Systems - Open Systems Interconnection - Service Conventions. ISO/TR 8509 has been withdrawn. See ISO/IEC 2382-26:1993 Information technology - Vocabulary - Part 26: Open systems interconnection .
[ISO 8825-1] 2002. Information technology - ASN.1 encoding rules: Specification of Basic Encoding Rules (BER), Canonical Encoding Rules (CER) and Distinguished Encoding Rules (DER).
[ISO/IEC 8859-1] 1987. Information processing - 8-bit single-byte coded graphic character sets - Part 1: Latin alphabet No. 1.
[ISO/IEC 8859-2] 1987. Information processing - 8-bit single-byte coded graphic character sets - Part 2: Latin alphabet No. 2.
[ISO/IEC 8859-3] 1988. Information processing - 8-bit single-byte coded graphic character sets - Part 3: Latin alphabet No. 3.
[ISO/IEC 8859-4] 1988. Information processing - 8-bit single-byte coded graphic character sets - Part 4: Latin alphabet No. 4.
[ISO/IEC 8859-5] 1988. Information processing - 8-bit single-byte coded graphic character sets - Part 5: Latin/Cyrillic alphabet.
[ISO/IEC 8859-6] 1987. Information processing - 8-bit single-byte coded graphic character sets - Part 6: Latin/Arabic alphabet.
[ISO/IEC 8859-7] 1987. Information processing - 8-bit single-byte coded graphic character sets - Part 7: Latin/Greek alphabet.
[ISO/IEC 8859-8] 1988. Information processing - 8-bit single-byte coded graphic character sets - Part 8: Latin/Hebrew alphabet.
[ISO/IEC 8859-9] 1989. Information processing - 8-bit single-byte coded graphic character sets - Part 9: Latin alphabet No. 5.
[ISO/IEC 8859-15] 1999. Information technology — 8-bit single-byte coded graphic character sets — Part 15: Latin alphabet No. 9.
[ISO/IEC 10118-3] 1998. Information technology - Security techniques - Hash-functions - Part 3: Dedicated hash-functions (RIPEMD-160 reference). The draft RIPEMD-160 specification and sample code are also available at http://homes.esat.kuleuven.be/~bosselae/ripemd160.html .
[ISO/IEC 10646] 2020. Information Technology - Universal Coded Character Set (UCS). ISO/IEC 10646-2020 is the same as Unicode Version 13.0, available at http://unicode.org .
[ISO/IEC 10918-1] 1994. JPEG Standard for digital compression and encoding of continuous-tone still images. Part 1 - Requirements and implementation guidelines.
[ISO/IEC 10918-5] 2013. JPEG Standard for digital compression and encoding of continuous-tone still images. Part 5 - JPEG File Interchange Format (JFIF).
[ISO 11664-4] 2008. Colorimetry - Part 4: CIE 1976 L*a*b* Colour space. ISO 11664-4 2008 is the same as CIE S 014-4/E:2007 .
[ISO 12232] 2006. Photography - Digital still cameras - Determination of exposure index, ISO speed ratings, standard output sensitivity, and recommended exposure index. http://www.iso.org/standard/37777.html .
[ISO 12233] 2018. Photography - Electronic still picture imaging - Resolution and spatial frequency responses. http://www.iso.org/standard/71696.html .
[ISO 12234-2] 2001. Electronic still-picture imaging - Removable memory - Part 2: TIFF/EP image data formats. http://www.iso.org/standard/29377.html .
[ISO/IEC 13818-1] 2000. Information technology - Generic coding of moving pictures and associated audio information: Systems.
[ISO/IEC 13818-2] 2000. Information technology - Generic coding of moving pictures and associated audio information: Video.
[ISO/IEC 13818-3] 1998. Information technology - Generic coding of moving pictures and associated audio information - Part 3: Audio.
[ISO/IEC 13818-4] 2004. Information technology - Generic coding of moving pictures and associated audio information - Part 4: Conformance testing.
[ISO/IEC 14495-1] 1997. Lossless and near-lossless coding of continuous tone still images (JPEG-LS).
[ISO/IEC 14496-10] 2009. Information technology - Coding of audio-visual objects - Part 210: Advanced Video Coding. http://www.iso.org/iso/iso_catalogue/catalogue_tc/catalogue_detail.htm?csnumber=52974 .
[ISO/IEC 14496-22] Information technology - Coding of audio-visual objects - Part 22: Open Font Format. http://www.iso.org/iso/iso_catalogue/catalogue_tc/catalogue_detail.htm?csnumber=52136 .
[ISO 14524] 2009. Photography - Electronic still-picture cameras - Methods for measuring opto-electronic conversion functions (OECFs). http://www.iso.org/standard/43527.html .
[ISO 15076-1] 2005. Image technology colour management - Architecture, profile format, and data structure. Also available as ICC.1:2004-10 (Profile version 4.2.0.0), International Color Consortium, available at http://www.color.org/v4spec.xalter .
[ISO/IEC 18181-1] 2022. Information technology - JPEG XL Image Coding System - Part 1 Core Coding System.
[ISO 21320-1] 2015. Information technology – Document Container File – Part 1: Core. http://standards.iso.org/ittf/PubliclyAvailableStandards/c060101_ISO_IEC_21320-1_2015.zip .
[ISO 22028-2] 2013. Photography and graphic technology - Extended colour encodings for digital image storage, manipulation and interchange - Part 2: Reference output medium metric RGB colour image encoding (ROMM RGB). http://www.iso.org/iso/catalogue_detail.htm?csnumber=56591 .
[ISO/IEC 23008-2] Information technology - High efficiency coding and media delivery in heterogeneous environments - Part 2: High efficiency video coding. http://www.iso.org/iso/iso_catalogue/catalogue_tc/catalogue_detail.htm?csnumber=67660 .
[ISO 32000-1] Document management - Portable document format - Part 1. http://www.iso.org/iso/catalogue_detail.htm?csnumber=51502 .
[IEC 60601-2-1] 2020. Ed.4. Medical Electrical Equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV.
[IEC 60601-2-33] 2010. Ed.3.1. Medical Electrical Equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis.
[IEC 60601-2-44] 2016. Ed.3.2. Medical Electrical Equipment - Part 2-44: Particular Requirements for the Safety of X-Ray Equipment for Computed Tomography.
[IEC 60601-2-63] 2012. Medical Electrical Equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-Ray equipment.
[IEC 60601-2-64] 2014. Medical Electrical Equipment - Part 2-64: Particular requirements for the basic safety and essential performance of light ion beam medical electrical equipment.
[IEC 61966-2.1] 1999. Ed 1.0. Multimedia systems and equipment - colour measurement and management - Part 2.1: colour management - Default RGB colour space - sRGB.
[IEC 62494-1] 2008. Medical electrical equipment - Exposure index of digital X-Ray imaging systems - Part 1: Definitions and requirements for general radiography.
[IEC 62563-1] 2009. Ed 1.0. Medical Electrical Equipment - Medical image display systems - Part 1: Evaluation methods.
[ISO IR 13] 1975. Registration - The Japanese KATAKANA graphic set of characters. http://www.itscj.ipsj.or.jp/iso-ir/013.pdf .
[ISO IR 14] 1975. Registration - The Japanese Roman graphic set of characters. http://www.itscj.ipsj.or.jp/iso-ir/014.pdf .
[ISO IR 100] 1986. Registration - Right-hand Part of the Latin Alphabet Nr. 1. http://www.itscj.ipsj.or.jp/iso-ir/100.pdf .
[ISO IR 101] 1986. Registration - Right-hand Part of the Latin Alphabet Nr. 2. http://www.itscj.ipsj.or.jp/iso-ir/101.pdf .
[ISO IR 109] 1986. Registration - Right-hand Part of the Latin Alphabet Nr. 3. http://www.itscj.ipsj.or.jp/iso-ir/109.pdf .
[ISO IR 110] 1986. Registration - Right-hand Part of the Latin Alphabet Nr. 4. http://www.itscj.ipsj.or.jp/iso-ir/110.pdf .
[ISO IR 126] 1986. Registration - Right-hand Part of the Latin/Greek alphabet. http://www.itscj.ipsj.or.jp/iso-ir/126.pdf .
[ISO IR 127] 1986. Registration - Right-hand Part of Latin/Arabic alphabet. http://www.itscj.ipsj.or.jp/iso-ir/127.pdf .
[ISO IR 138] 1987. Registration - Latin/Hebrew alphabet. http://www.itscj.ipsj.or.jp/iso-ir/138.pdf .
[ISO IR 144] 1988. Registration - Cyrillic Part of the Latin/Cyrillic Alphabet. http://www.itscj.ipsj.or.jp/iso-ir/144.pdf .
[ISO IR 148] 1988. Registration - Right-hand Part of Latin alphabet No. 5. http://www.itscj.ipsj.or.jp/iso-ir/148.pdf .
[ISO IR 166] 1992. Registration - Thai Character Set. http://www.itscj.ipsj.or.jp/iso-ir/166.pdf .
[ISO IR 192] 1996. Registration - UCS Transformation Format (UTF-8), implementation level 3, without standard return. http://www.itscj.ipsj.or.jp/iso-ir/192.pdf .
[ISO IR 203] 1998. Registration - European supplementary Latin set ("Latin 9"). http://www.itscj.ipsj.or.jp/iso-ir/203.pdf .
[ITU-T X.509] 2000. Information technology - Open Systems Interconnection - The directory: Public-key and attribute certificate frameworks. ITU-T Recommendation X.509 is similar to ISO/IEC 9594-8 1990. However, the ITU-T recommendation is the more familiar form, and was revised in 1993 and 2000, with two sets of corrections in 2001. ITU-T was formerly known as CCITT. .
[RFC1321] The MD5 Message-Digest Algorithm. http://tools.ietf.org/html/rfc1321 .
[RFC1951] DEFLATE Compressed Data Format Specification Version 1.3. http://tools.ietf.org/html/rfc1952 .
[RFC1952] GZIP file format specification version 4.3. http://tools.ietf.org/html/rfc1952 .
[RFC2046] November 1996. Multipurpose Internet Mail Extensions (MIME) Part Two: Media Types. http://tools.ietf.org/html/rfc2046 .
[RFC2437] October 1998. PKCS #1 RSA Cryptography Specifications Version 2.0. http://tools.ietf.org/html/rfc2437 . The RSA Encryption Standard is also defined in informative Annex A of ISO/IEC 9796, and in Normative Annex A of the CEN/TC251 European Prestandard prENV 12388:1996. .
[RFC3161] Internet X.509 Public Key Infrastructure; Time Stamp Protocols. http://tools.ietf.org/html/rfc3161 .
[RFC3986] Uniform Resource Identifiers (URI): Generic Syntax. http://tools.ietf.org/html/rfc3986 .
[RFC5652] September 2009. Cryptographic Message Syntax. http://tools.ietf.org/html/rfc5652 .
[RFC6151] March 2011. Updated Security Considerations for the MD5 Message-Digest and the HMAC-MD5 Algorithms. http://tools.ietf.org/html/rfc6151 .
[RFC7230] Hypertext Transfer Protocol (HTTP/1.1): Message Syntax and Routing. http://tools.ietf.org/html/rfc7230 .
[RFC7231] Hypertext Transfer Protocol (HTTP/1.1): Semantics and Content. http://tools.ietf.org/html/rfc7231 .
[RFC7530] Network File System (NFS) Version 4 Protocol. http://tools.ietf.org/html/rfc7530 .
[HL7 V2.5] 2003. HL7 Standard Version 2.5 - An Application Protocol for Electronic Data Exchange in Healthcare Environments. http://www.hl7.org/documentcenter/private/standards/V25/HL7_Messaging_v25_PDF.zip .
[HL7 CDA R1] 2000. HL7 Version 3 Standard: Clinical Document Architecture Framework, Release 1. http://www.hl7.org/documentcenter/private/standards/cda/r1/HL7_CDA_R1_FINAL.zip .
[HL7 CDA R2] 2005. HL7 Version 3 Standard: Clinical Document Architecture Framework, Release 2. http://www.hl7.org/documentcenter/private/standards/cda/r2/cda_r2_normativewebedition2010.zip .
[HL7 SPL R1.0] 2004. HL7 Structured Product Labeling Standard, Release 1.0. http://www.hl7.org/documentcenter/private/standards/SPL/SPL_Specification_ANSI_R1.0-2004.zip .
[FIPS PUB 46] . Data Encryption Standard (DES). Withdrawn . http://csrc.nist.gov/publications/fips/archive/fips46-3/fips46-3.pdf .
[FIPS PUB 180-4] August 2015. Secure Hash Standard (SHS). http://doi.org/10.6028/NIST.FIPS.180-4 .
[FIPS PUB 202] August 2015. SHA-3 Standard. http://doi.org/10.6028/NIST.FIPS.202 .
[ACR-NEMA 300-1985] 1985. Digital Imaging and Communications. http://dicom.nema.org/medical/dicom/1985/ACR-NEMA_300-1985.pdf .
[ACR-NEMA 300-1988] 1988. Digital Imaging and Communications. http://dicom.nema.org/medical/dicom/1988/ACR-NEMA_300-1988.pdf .
[Adobe RGB] 1998. 2005-05. Adobe RGB (1998) Color Image Encoding. http://www.adobe.com/digitalimag/pdfs/AdobeRGB1998.pdf .
[Anderson 1986] Medical Physics. 1986. 6. 898-903. “A "natural" volume-dose histogram for brachytherapy”. doi:10.1118/1.595815
[ANSI X9.52] 1998. Triple Data Encryption Algorithm Modes of Operation, Accredited Standards Committee (ASC) X9, Financial Services.
[APEX] August 4, 2007. APEX — The Additive System of Photographic Exposure. http://dougkerr.net/Pumpkin/articles/APEX.pdf .
[BI-RADS®] 1998. 3.0. Breast Imaging Reporting and Data System Atlas. http://www.acr.org/Quality-Safety/Resources/BIRADS .
[ECMA 235] 1996. The ECMA GSS-API Mechanism. http://www.ecma-international.org/publications/standards/Ecma-235.htm .
[EXIF 2.31] July 2016. 2.31. Exchangeable Image File Format for Digital Still Cameras - CIPA DC-008, JEITA CP-3451C Translation. http://cipa.jp/std/documents/e/DC-008-Translation-2016-E.pdf .
[FDA UDI] 2016. 1.2. UDI formats by FDA-Accredited Issuing Agency. http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/UniqueDeviceIdentification/UDIIssuingAgencies/UCM489869.pdf .
[JIS X 0212] 1990. Code of the supplementary Japanese Graphic Character set for information interchange.
[NEMA UD3] 2004. Standard for Real-Time Display of Thermal and Mechanical Acoustic Output Indices on Diagnostic Ultrasound Equipment.
[IEEE 754] 2019. IEEE Standard for Floating Point Arithmetic. http://dx.doi.org/10.1109/IEEESTD.2019.8766229 .
[IEEE 1588] 2008. Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems. doi:10.1109/IEEESTD.2008.4579760
[IHE ITI TF-2b] 2020. Integrating the Healthcare Enterprise Radiology Technical Framework Volume 2b Transactions Part B – Sections 3.29 – 3.64. http://www.ihe.net/uploadedFiles/Documents/ITI/IHE_ITI_TF_Vol2b.pdf .
[IHE RAD TF-1] 2020. Integrating the Healthcare Enterprise Radiology Technical Framework Volume 1 Integration Profiles. http://www.ihe.net/uploadedFiles/Documents/Radiology/IHE_RAD_TF_Vol1.pdf .
[IHE RAD TF-1x] 2020. Integrating the Healthcare Enterprise Radiology Technical Framework Volume 1x Appendices to Integration Profiles. http://www.ihe.net/uploadedFiles/Documents/Radiology/IHE_RAD_TF_Vol1x.pdf .
[IHE RAD TF-2] 2020. Integrating the Healthcare Enterprise Radiology Technical Framework Volume 2 Transactions. http://www.ihe.net/uploadedFiles/Documents/Radiology/IHE_RAD_TF_Vol2.pdf .
[IHE RAD TF-2x] 2020. Integrating the Healthcare Enterprise Radiology Technical Framework Volume 2x Appendices to Transactions. http://www.ihe.net/uploadedFiles/Documents/Radiology/IHE_RAD_TF_Vol2x.pdf .
[IHE RAD TF-3] 2020. Integrating the Healthcare Enterprise Radiology Technical Framework Volume 3 Cross-Transaction Specifications and Content Specifications. http://www.ihe.net/uploadedFiles/Documents/Radiology/IHE_RAD_TF_Vol3.pdf .
[IHE RAD TF-4] 2020. Integrating the Healthcare Enterprise Radiology Technical Framework Volume 4 National Extensions. http://www.ihe.net/uploadedFiles/Documents/Radiology/IHE_RAD_TF_Vol4.pdf .
[OBJ] 1992. Advanced Visualizer. B1. Object Files (.obj). http://www.cs.utah.edu/~boulos/cs3505/obj_spec.pdf .
[PDF] 1985. Fifth Edition. PDF Reference, version 1.6. http://www.adobe.com/devnet/pdf/pdf_reference_archive.html .
[TIS 620-2533] 1990. Thai Characters Code for Information Interchange. http://www.nectec.or.th/it-standards/std620/std620.html .
[McCollough 2007] Radiology. 2007. 2. 527. “A multi-institutional, multi-manufacturer, international standard for the quantification of coronary artery calcium using cardiac CT”. doi:10.1148/radiol.2432050808
[CSS2] 2011. Cascading Style Sheet (CSS) CSS2 generic font families. http://www.w3.org/TR/REC-CSS2/fonts.html#generic-font-families .
[HPGL] . PCL/PJL Reference PCL5 Printer Language Technical Reference Manual. IIHP 5961-0509. http://www.hp.com/ctg/Manual/bpl13211.pdf .
[AAPM TG 116] July 2009. Report of AAPM Task Group 116 - An Exposure Indicator for Digital Radiography. http://www.aapm.org/pubs/reports/rpt_116.pdf .
[AAPM Report 204] 2011. Report of AAPM Task Group 204 - Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations. http://www.aapm.org/pubs/reports/RPT_204.pdf .
[AAPM Report 220] September 2014. Report of AAPM Task Group 220 - Use of Water Equivalent Diameter for Calculating Patient Size and Size-Specific Dose Estimates (SSDE) in CT. http://www.aapm.org/pubs/reports/rpt_220.pdf .
[AAPM OR 03] 2005. Assessment of Display Performance for Medical Imaging Systems. http://www.aapm.org/pubs/reports/OR_03.pdf .
[DIN 6868-57] 2001. Image quality assurance in diagnostic X-Ray departments - Acceptance testing for image display devices.
[US 6,272,235] Method and Apparatus for Creating a Virtual Microscope Slide. US Patent. 6,272,235. August 7, 2001.
[Porter and Duff 1984] Computer Graphics. 1984. 3. 253-259. “Compositing Digital Images”. doi:10.1145/800031.808606 http://keithp.com/~keithp/porterduff/p253-porter.pdf .
[Phong 1975] Communications of the ACM. 1975. 6. 311-317. “Illumination for computer generated pictures”. doi:10.1145/360825.360839 http://www.cs.northwestern.edu/~ago820/cs395/Papers/Phong_1975.pdf .
[Poynton 2008] 2008/01/24. Chroma subsampling notation. http://www.poynton.com/PDFs/Chroma_subsampling_notation.pdf .
[POSIX] 2017. POSIX.1-2017 (IEEE Std 1003.1™-2017). http://pubs.opengroup.org/onlinepubs/9699919799/ .
[ZIP] 1989. ZIP File Format Specification. http://www.pkware.com/documents/casestudies/APPNOTE.TXT .
[Chytyk-Praznik 2013] Med Phys. 2013. 3. 031713. “Model-based prediction of portal dose images during patient treatment”. doi:10.1118/1.4792203
DICOM PS3.3 2024d - Information Object Definitions |
---|