| DICOM PS3.20 2024c - Imaging Reports using HL7 Clinical Document Architecture |
|---|
|
Records details about the reason for the procedure. This section may include the pre-procedure diagnosis or diagnoses as well as one or more symptoms that contribute to the reason the procedure is being performed. |
|
|
Included in 9.2 Clinical Information |
|
|
DICOM-20150324: adapted to use optional Coded Observation entry rather than optional Indication entry |
|
9.1.1 Section Text 1.2.840.10008.9.19 |
||||||||
|
10.1 Coded Observation 2.16.840.1.113883.10.20.6.2.13 |
The binding to the Coded Observation concept domains is:
In Consolidated CDA r1.1 the binding to the observationType is to Value Set Problem Type (2.16.840.1.113883.3.88.12.3221.7.2) with conformance SHOULD. Values from that Value Set are acceptable here as well.
Example 9.8.2.1-1. Procedure indications section example
<section classCode="DOCSECT" moodCode="EVN">
<templateId root="2.16.840.1.113883.10.20.22.2.29"/>
<id root="1.2.840.10213.2.62.044785528.1142895426"/>
<code code="59768-2"
codeSystem="2.16.840.1.113883.6.1"
codeSystemName="LOINC"
displayName="Procedure Indications"/>
<title>Procedure Indications</title>
<text>The procedure is performed as a follow-up for abnormal screening result.</text>
</section>
| DICOM PS3.20 2024c - Imaging Reports using HL7 Clinical Document Architecture |
|---|