DICOM PS3.20 2024c - Imaging Reports using HL7 Clinical Document Architecture

10.7 Series Act

Template ID

1.2.840.10008.9.17

Name

Series Act

Effective Date

2015/03/24

Version Label

DICOM-20150324

Status

Active

Description

A Series Act contains the DICOM series information for referenced DICOM composite objects. The series information defines the attributes that are used to group composite instances into distinct logical sets. Each series is associated with exactly one study. Series Act clinical statements are only instantiated in the 9.8.7 DICOM Object Catalog section inside a 10.6 Study Act.

Classification

CDA Entry Level

Relationships

Included in 10.6 Study Act

Context

parent node

Open/Closed

open

Revision History

DICOM-20150324: Initial publication, derived from template originally published in DIR r1-2009, revised in Consolidated CDA r1-2011 as 2.16.840.1.113883.10.20.22.4.63. This derivation uses DICOM-20150324 SOP Instance subsidiary template.

Business Name

Nest Level

Element/​Attribute

Card

Elem/Attr Conf

Data Type

Value Conf

Value

Subsidiary Template

Series[*]

act

1..1

SHALL

@

@classCode

1..1

SHALL

CS

SHALL

ACT

@

@moodCode

1..1

SHALL

CS

SHALL

EVN

>

template​Id

1..1

SHALL

II

>@

@root

1..1

SHALL

UID

SHALL

1.2.840.10008.9.17

>

id

1..1

SHALL

Series​UID

>@

@root

1..1

SHALL

UID

Series Instance UID (0020,000E)

>@

@extension

0..0

SHALL NOT

>

code

1..1

SHALL

CD

SHALL

(113015, DCM, "Series")

>>

qualifier

1..1

SHALL

>>>

name

1..1

SHALL

CD

SHALL

(121139, DCM, "Modality")

Modality

>>>

value

1..1

SHALL

CD

Modality (0008,0060)

Description

>

text

0..1

MAY

ED

Time

>

effective​Time

0..1

SHOULD

TS

Series Date (0008,0021) + Series Time (0008,0031) + Timezone Offset From UTC (0008,0201)

>

entry​Relationship

1..*

SHALL

>@

@typeCode

1..1

SHALL

CS

SHALL

COMP

SOPInstance[*]

>>

observation

1..1

10.8 SOP Instance Observation 1.2.840.10008.9.18

Example 10.7-1. Series act example

<act classCode="ACT" moodCode="EVN">
    <templateId root="1.2.840.10008.9.17"/>
    <id root="1.2.840.113619.2.62.994044785528.20060823223142485051"/>
    <code code="113015" codeSystem="1.2.840.10008.2.16.4"
            codeSystemName="DCM" displayName="Series">
        <qualifier>
            <name code="121139" codeSystem="1.2.840.10008.2.16.4"
                codeSystemName="DCM"
                displayName="Modality"/>
            <value code="CR" codeSystem="1.2.840.10008.2.16.4"
                codeSystemName="DCM"
                displayName="Computed Radiography"/>
        </qualifier>
    </code>
    <!-- **** SOP Instance UID *** -->
    <entryRelationship typeCode="COMP">
        <observation classCode="DGIMG" moodCode="EVN">
            <templateId root="2.16.840.1.113883.10.20.6.2.8"/>
            ...
        </observation>
    </entryRelationship>
</act>

DICOM PS3.20 2024c - Imaging Reports using HL7 Clinical Document Architecture