DICOM PS3.18 2024c - Web Services
10.6.3.3.2 Series Resources

For each matching Series, the origin server shall return all Attributes listed in Table 10.6.3-4. The "Type" column in the table below refers to the Query/Retrieve Attribute Types defined in Section C.2.2.1 “Attribute Types” in PS3.4. The unique key for a Series resource Search response is the Series Instance UID (0020,000E).

Table 10.6.3-4. Series Resources Search Response Payload

Attribute Name

Tag

Type

Condition

Modality

(0008,0060)

R

Timezone Offset From UTC

(0008,0201)

C

Shall be present if known

Series Description

(0008,103E)

C

Shall be present if known

Retrieve URL

(0008,1190)

R

Shall be present if the Instance is retrievable by the Retrieve transaction

Series Instance UID

(0020,000E)

U

Series Number

(0020,0011)

R

Number of Series Related Instances

(0020,1209)

R

Performed Procedure Step Start Date

(0040,0244)

C

Shall be present if known

Performed Procedure Step Start Time

(0040,0245)

C

Shall be present if known

Request Attributes Sequence

(0040,0275)

C

Shall be present if known

>Scheduled Procedure Step ID

(0040,0009)

R

>Requested Procedure ID

(0040,1001)

R


Note

  1. While some of the above Attributes in are optional in Table C.6-3 “Series Level Attributes for the Patient Root Query/Retrieve Information Model” in PS3.4, they are consistent with the those required in [IHE RAD TF Vol2] Table 4.14-1.

  2. If either Prior Record Key (0008,041C) or Record Key (0008,041B) is present in the request and the origin server supports these attributes, then the responses are ordered as defined in Section C.6.4 “Repository Query SOP Class” in PS3.4.

In addition, the response shall contain:

Instance Level Attributes contained in includefield parameters shall not be returned.

DICOM PS3.18 2024c - Web Services