The response shall have the following syntax:
version SP status-code SP reason-phrase CRLF
[Content-Type: media-type CRLF]
[(Content-Length: uint / Transfer-Encoding: encoding) CRLF]
[Content-Location: url CRLF]
*(header-field CRLF)
CRLF
payload / status-report
Table 10.4.3-1 shows some common status codes corresponding to this transaction. See also Section 8.5 for additional status codes.
Table 10.4.3-1. Status Code Meaning
|
Status
|
Code
|
Meaning
|
|
Success
|
200 (OK)
|
The response payload contains representations for all of the Target Resource(s)
|
|
206 (Partial Content)
|
The response payload contains representations for some, but not all, of the Target Resource(s)
|
|
Failure
|
400 (Bad Request)
|
The origin server cannot process the request because of errors in the request headers or parameters.
|
|
404 (Not Found)
|
The Target Resource does not exist
|
|
406 (Not Acceptable)
|
The origin server does not support any of the Acceptable Media Types
|
|
410 (Gone)
|
The Target Resource has been deleted
|
|
413 (Payload Too Large)
|
The Target Resource is too large to be returned by the origin server.
|