| DICOM PS3.17 2024c - Explanatory Information |
|---|
Goal: A Hanging Protocol for MR & CT of Head, for a neurosurgery plan. 1Kx1K screen on left shows orthogonal MPR slices through the acquisition volume, and in one presentation group has a 3D interactive volume rendering in the lower right quadrant. In all display sets the 1Kx1K screen is split into 4 512x512 quadrants. The 2560x2048 screen has a 4 row by 3 column tiled display area. There are 4 temporal presentation groups: CTnew, MR, combined CTnew and MR, combined CTnew and CTold.
Display Environment Spatial Position Attribute values for image boxes are represented in terms of ratios in pixel space [(0/3072, 512/2560), (512/3072,0/2560)] rather than (0.0,0.0), (1.0,1.0) space, for ease of understanding the example.
Hanging Protocol Description: "Neurosurgery planning, requiring MR and CT of head"
Hanging Protocol Definition Sequence:
Item 1: (69536005, SCT, "Head")
Item 1: (69536005, SCT, "Head")
Hanging Protocol User Identification Code Sequence: zero length
| DICOM PS3.17 2024c - Explanatory Information |
|---|