| DICOM PS3.17 2024c - Explanatory Information |
|---|
An alternative method is to replicate the entire Image SOP Instance with a new SOP Instance UID, and assign each Image IOD it's own identifying Attributes. In this case, each of the Study Instance UID and the Accession Number values can be used in their own Image SOP Instance.
Both Image SOP Instances may reference a single MPPS SOP Instance (via the MPPS SOP Instance UID in the Referenced Performed Procedure Step Sequence).
Each individual Image SOP Instance may reference it's own related Study SOP Instance, if it exists (via the Referenced Study Sequence). This Study SOP Instance has a one to one relationship with the corresponding Requested Procedure.
If an MPPS SOP Instance is created, it may reference both related Study SOP Instances.
For all Series in the MPPS, replicate the entire Series of Images using new Series Instance UIDs
Create replicated Image SOP Instances with different SOP Instance UIDs that use the new Series Instance UIDs, for each of the two or more Requested Procedures
In each of the Image SOP Instances, using values from the corresponding Requested Procedure:
In the MPPS SOP Instance (if supported):
In both the Image SOP Instances and the MPPS SOP Instance (if supported):
| DICOM PS3.17 2024c - Explanatory Information |
|---|