DICOM PS3.17 2024c - Explanatory Information

FFFF.3 Encoding Example

Table FFFF.3-1. Encoding Example

Nesting

Attribute Name

Tag

Value

Comment

Advanced Blending Sequence

(0070,1B01)

%item 1

Identifies Anatomical Series, no subset of series or registration

>

Blending Input Number

(0070,1B02)

1

>

Study Instance UID

(0020,000D)

"1.3.46.670589.11.3"

>

Series Instance UID

(0020,000E)

"1.3.46.670589.11.3.45"

>

Geometry for Display

(0070,1B08)

TRUE

Series geometry shall be used as target geometry for the blending operation

%enditem 1

%item 2

Identifies DTI Series, no subset of series is used, no registration present

>

Blending Input Number

(0070,1B02)

2

>

Study Instance UID

(0020,000D)

"1.3.46.670589.11.3"

>

Series Instance UID

(0020,000E)

"1.3.46.670589.11.3.49"

>

Geometry for Display

(0070,1B08)

FALSE

Series geometry shall not be used as target geometry for the blending operation

%enditem 2

%item 3

Identifies first Parametric map, no registration

>

Blending Input Number

(0070,1B02)

3

>

Study Instance UID

(0020,000D)

"1.3.46.670589.11.3"

>

Series Instance UID

(0020,000E)

"1.3.46.670589.11.3.56"

>

Threshold Sequence

(0070,1B11)

>

%item 3-1

>>

Threshold Value Sequence

(0070,1B12)

>>

%item 3-1-1

>>>

Threshold Value

(0070,1B14)

6

First threshold value

>>

%enditem 3-1-1

>>

%item 3-1-2

>>>

Threshold Value

(0070,1B14)

50

Second threshold value

>>

%enditem 3-1-2

>>

Threshold Type

(0070,1B13)

RANGE_INCL

>

%enditem 3-1

%enditem 3

%item 4

Identifies second Parametric map, no registration

>

Blending Input Number

(0070,1B02)

3

>

Study Instance UID

(0020,000D)

"1.3.46.670589.11.3"

>

Series Instance UID

(0020,000E)

"1.3.46.670589.11.3.58"

>

Threshold Sequence

(0070,1B11)

>

%item 4-1

>>

Threshold Value Sequence

(0070,1B12)

>>>

%item 4-1-1

>>>

Threshold Value

(0070,1B14)

9

First threshold value

>>

%enditem 4-1-1

>>

%item 4-1-2

>>>

Threshold Value

(0070,1B14)

60

Second threshold value

>>

%enditem 4-1-2

>>

Threshold Type

(0070,1B13)

RANGE_INCL

>

%enditem 4-1

%enditem 4

%item 5

Identifies third Parametric map, no registration

>

Blending Input Number

(0070,1B02)

3

>

Study Instance UID

(0020,000D)

"1.3.46.670589.11.3"

>

Series Instance UID

(0020,000E)

"1.3.46.670589.11.3.59"

>

Threshold Sequence

(0070,1B11)

>

%item 5-1

>>

Threshold Value Sequence

(0070,1B12)

>>

%item 5-1-1

>>>

Threshold Value

(0070,1B14)

7

First threshold value

>>

%enditem 5-1-1

>>

%item 5-1-2

>>>

Threshold Value

(0070,1B14)

75

Second threshold value

>>

%enditem 5-1-2

>>

Threshold Type

(0070,1B13)

RANGE_INCL

>

%enditem 5-1

%enditem 5

Pixel Presentation

(0008,9205)

"TRUE_COLOR"

Blending Display Sequence

(0070,1B04)

%item 1

>

Blending Display Input Sequence

(0070,1B03)

>

%item 1-1

Anatomical series, no threshold

>>

Blending Input Number

(0070,1B02)

1

>

%enditem 1-1

>

%item 1-2

DTI series, no threshold

>>

Blending Input Number

(0070,1B02)

2

>

%enditem 1-2

>

Relative Opacity

(0070,0403)

0.7

>

Blending Mode

(0070,1B06)

FOREGROUND

>

Blending Input Number

(0070,1B02)

6

Output is used for later Blending

%enditem 1

%item 2

>

Blending Display Input Sequence

(0070,1B03)

>

%item 2-1

Parametric series 1

>>

Blending Input Number

(0070,1B02)

3

>

%enditem 2-1

>

%item 2-2

Parametric series 2

>>

Blending Input Number

(0070,1B02)

4

>

%enditem 2-2

>

%item 2-3

Parametric series 3

>>

Blending Input Number

(0070,1B02)

5

>

End Sequence Item 2-3

>

Blending Mode

(0070,1B06)

EQUAL

>

Blending Input Number

(0070,1B02)

7

Output is used for later Blending

%enditem 2

%item 3

>

Blending Display Input Sequence

(0070,1B03)

>

%item 3-1

Output first blending operation, no threshold

>>

Blending Input Number

(0070,1B02)

6

>

%enditem 3-1

>

%item 3-2

Output second blending operation, no threshold

>>

Blending Input Number

(0070,1B02)

7

>

%enditem 3-2

>

Relative Opacity

(0070,0403)

0.6

>

Blending Mode

(0070,1B06)

FOREGROUND

%enditem 3

No Parametric Blending Input Number is present as this step defines the output to be displayed.


DICOM PS3.17 2024c - Explanatory Information