DICOM PS3.17 2024c - Explanatory Information

NNNN Mapping of Visible Light Photography Related Attributes to EXIF and TIFF/EP Tags (Informative)

NNNN.1 Mapping

NNNN-1 describes a mapping of EXIF Tags as defined in [EXIF 2.31] and TIFF/EP Tags as defined in [ISO 12234-2] to Visible Light Photography related Attributes. The list of EXIF and associated TIFF tags was derived from the table at http://www.exiv2.org/tags.html, updated to remove redundancies and resolve differences between EXIF 2.3 and 2.31. The intent is that this mapping support the extraction of embedded EXIF information into DICOM Attributes for accessibility in DICOM-based systems. It is not intended to define a deterministic mapping supporting round-trip full-fidelity conversion from EXIF to DICOM and back to EXIF again. Not all EXIF Tags are mapped.

When mapping EXIF values to DICOM, some tags map to multiple DICOM Attributes and vice versa, as noted. In general, Ascii types are mapped to UT VR (except that dates and times and timezone offsets are mapped to the appropriate DA, TM, DT or SH VR), Short and Long are mapped to IS VR unless they are used for a list of defined terms, in which case US VR is used, Rational and SRational are mapped to DS (VR) (i.e., each numerator and denominator pair is mapped to a single decimal representation), and Undefined is mapped to OB or UT VR as appropriate. In some special cases, the structure within a single EXIF value is expected to be decoded, e.g., the tabular representation of the OECF and Spatial Frequency Response. An appropriate choice of DICOM Specific Character Set and any corresponding character set mapping encoding conversion is expected; special handling of the decoding of character sets may be necessary for some EXIF tags, such as 37510 UserComment.

Some unmapped EXIF tags may theoretically influence the way in which an image might be displayed differently than it is encoded. E.g., Orientation (274) may contain enumerated values describing the "image orientation viewed" in terms of "visual rows and columns" related to encoded rows and columns, is not mapped. This may be a factor if the camera is physically rotated or if the user has edited the preferred orientation. In theory, such information could be mapped to a Presentation State, which is not defined by this Annex. There is no expectation that the mapping will involve re-encoding the pixel data in a different orientation, though this is not explicitly forbidden.

In NNNN-1, the word "tag" in the columns labelled "EXIF or TIFF Tag" and "EXIF or TIFF Tag description" refer to the tag in the EXIF or TIFF standards and not the DICOM Tag.

Table NNNN-1. Mapping of Visible Light Photography Related Attributes to EXIF Tags

DICOM Tag

Attribute Name

DICOM Module

EXIF or TIFF Tag (hex)

EXIF or TIFF Tag (dec)

EXIF or TIFF IFD

EXIF or TIFF Key

EXIF or TIFF Type

EXIF or TIFF Tag Description

(0008,0201)

Timezone Offset From UTC

SOP Common Module

0x9010

36880

Photo 231

Offset​Time

Ascii

A tag used to record the offset from UTC (the time difference from Universal Time Coordinated including daylight saving time) of the time of Date​Time tag. The format when recording the offset is "±HH:MM". The part of "±" shall be recorded as "+" or "-". When the offset are unknown, all the character spaces except colons (":") should be filled with blank characters, or else the Interoperability field should be filled with blank characters. The character string length is 7 Bytes including NULL for termination. When the field is left blank, it is treated as unknown.

(0008,0201)

Timezone Offset From UTC

SOP Common Module

0x9011

36881

Photo 231

Offset​Time​Original

Ascii

A tag used to record the offset from UTC (the time difference from Universal Time Coordinated including daylight saving time) of the time of Date​Time​Original tag. The format when recording the offset is "±HH:MM". The part of "±" shall be recorded as "+" or "-". When the offset are unknown, all the character spaces except colons (":") should be filled with blank characters, or else the Interoperability field should be filled with blank characters. The character string length is 7 Bytes including NULL for termination. When the field is left blank, it is treated as unknown.

(0008,0201)

Timezone Offset From UTC

SOP Common Module

0x9012

36882

Photo 231

Offset​Time​Digitized

Ascii

A tag used to record the offset from UTC (the time difference from Universal Time Coordinated including daylight saving time) of the time of Date​TimeDigitized tag. The format when recording the offset is "±HH:MM". The part of "±" shall be recorded as "+" or "-". When the offset are unknown, all the character spaces except colons (":") should be filled with blank characters, or else the Interoperability field should be filled with blank characters. The character string length is 7 Bytes including NULL for termination. When the field is left blank, it is treated as unknown.

(0016,0030)

Temperature

VL Photographic Acquisition Module

0x9400

37888

Photo 231

Temperature

SRational

Temperature as the ambient situation at the shot, for example the room temperature where the photographer was holding the camera. The unit is °C. If the denominator of the recorded value is FFFFFFFF.H, unknown shall be indicated. Obtaining method or accuracy is not stipulated. Therefore methods like that the photographer manually input the numeric, as an example, are usable.

(0016,0031)

Humidity

VL Photographic Acquisition Module

0x9401

37889

Photo 231

Humidity

Rational

Humidity as the ambient situation at the shot, for example the room humidity where the photographer was holding the camera. The unit is %. If the denominator of the recorded value is FFFFFFFF.H, unknown shall be indicated. Obtaining method or accuracy is not stipulated. Therefore methods like that the photographer manually input the numeric, as an example, are usable.

(0016,0032)

Pressure

VL Photographic Acquisition Module

0x9402

37890

Photo 231

Pressure

Rational

Pressure as the ambient situation at the shot, for example the room atmospfere where the photographer was holding the camera or the water pressure under the sea. The unit is hPa. If the denominator of the recorded value is FFFFFFFF.H, unknown shall be indicated. Obtaining method or accuracy is not stipulated. Therefore methods like that the photographer manually input the numeric, as an example, are usable.

(0016,0033)

Water Depth

VL Photographic Acquisition Module

0x9403

37891

Photo 231

Water​Depth

SRational

Water depth as the ambient situation at the shot, for example the water depth of the camera at underwater photography. The unit is m. When the value is negative, the absolute value of it indicates the height (elevation) above the water level. If the denominator of the recorded value is FFFFFFFF.H, unknown shall be indicated. Obtaining method or accuracy is not stipulated. Therefore methods like that the photographer manually input the numeric, as an example, are usable.

(0016,0034)

Acceleration

VL Photographic Acquisition Module

0x9404

37892

Photo 231

Acceleration

Rational

Acceleration (a scalar regardless of direction) as the ambient situation at the shot, for example the driving acceleration of the vehicle which the photographer rode on at the shot. The unit is mGal (10-5 m/s2). If the denominator of the recorded value is FFFFFFFF.H, unknown shall be indicated. Obtaining method or accuracy is not stipulated. Therefore methods like that the photographer manually input the numeric, as an example, are usable.

(0016,0035)

Camera Elevation Angle

VL Photographic Acquisition Module

0x9405

37893

Photo 231

Camera​ElevationAngle

SRational

Elevation/depression. angle of the orientation of the camera(imaging optical axis) as the ambient situation at the shot. The unit is degree(°). The range of the value is from -180 to less than 180. If the denominator of the recorded value is FFFFFFFF.H, unknown shall be indicated. Obtaining method or accuracy is not stipulated. Therefore methods like that the photographer manually input the numeric, as an example, are usable.

(0016,0004)

Exposure Time in Seconds

VL Photographic Acquisition Module

0x829a

33434

Photo

Exposure​Time

Rational

Exposure time, given in seconds (sec).

(0016,0005)

F-Number

VL Photographic Acquisition Module

0x829d

33437

Photo

FNumber

Rational

The F number.

(0016,0016)

Exposure Program

VL Photographic Acquisition Module

0x8822

34850

Photo

Exposure​Program

Short

The class of the program used by the camera to set exposure when the picture is taken.

(0016,0017)

Spectral Sensitivity

VL Photographic Acquisition Module

0x8824

34852

Photo

Spectral​Sensitivity

Ascii

Indicates the spectral sensitivity of each channel of the camera used. The tag value is an ASCII string compatible with the standard developed by the ASTM Technical Committee.

(0016,0018)

Photographic Sensitivity

VL Photographic Acquisition Module

0x8827

34855

Photo

PhotographicSensitivity

Short

Indicates the ISO Speed and ISO Latitude of the camera or input device as specified in [ISO 12232].

Formerly called ISOSpeed​Ratings.

(0016,0006), (0016,0007), (0016,0008), (0016,0009)

OECF Rows, OECF Columns, OECF Column Names, OECF Values

VL Photographic Acquisition Module

0x8828

34856

Photo

OECF

Undefined

Indicates the Opto-Electronic Conversion Function (OECF) specified in [ISO 14524]. <OECF> is the relationship between the camera optical input and the image values.

(0016,001A)

Sensitivity Type

VL Photographic Acquisition Module

0x8830

34864

Photo

Sensitivity​Type

Short

The Sensitivity​Type tag indicates which one of the parameters of ISO12232 is the Photographic​Sensitivity tag. Although it is an optional tag, it should be recorded when a Photographic​Sensitivity tag is recorded. Value = 4, 5, 6, or 7 may be used in case that the values of plural parameters are the same.

(0016,001B)

Standard Output Sensitivity

VL Photographic Acquisition Module

0x8831

34865

Photo

Standard​OutputSensitivity

Long

This tag indicates the standard output sensitivity value of a camera or input device defined in [ISO 12232]. When recording this tag, the Photographic​Sensitivity and Sensitivity​Type tags shall also be recorded.

(0016,001C)

Recommended Exposure Index

VL Photographic Acquisition Module

0x8832

34866

Photo

Recommended​ExposureIndex

Long

This tag indicates the recommended exposure index value of a camera or input device defined in [ISO 12232]. When recording this tag, the Photographic​Sensitivity and Sensitivity​Type tags shall also be recorded.

(0016,001D)

ISO Speed​

VL Photographic Acquisition Module

0x8833

34867

Photo

ISOSpeed

Long

This tag indicates the ISO speed value of a camera or input device that is defined in [ISO 12232]. When recording this tag, the Photographic​Sensitivity and Sensitivity​Type tags shall also be recorded.

(0016,001E)

ISO Speed​​ Latitude yyy

VL Photographic Acquisition Module

0x8834

34868

Photo

ISOSpeed​Latitudeyyy

Long

This tag indicates the ISO speed latitude yyy value of a camera or input device that is defined in [ISO 12232]. However, this tag shall not be recorded without ISOSpeed and ISOSpeed​Latitudezzz.

(0016,001F)

ISO Speed​​ Latitude zzz

VL Photographic Acquisition Module

0x8835

34869

Photo

ISOSpeed​Latitudezzz

Long

This tag indicates the ISO speed latitude zzz value of a camera or input device that is defined in [ISO 12232]. However, this tag shall not be recorded without ISOSpeed and ISOSpeed​Latitudeyyy.

(0016,0020)

EXIF Version

VL Photographic Acquisition Module

0x9000

36864

Photo

Exif​Version

Undefined

The version of this standard supported. Nonexistence of this field is taken to mean nonconformance to the standard. Encoded as 4-byte ASCII.

(0008,002A)

Acquisition Date​Time

General Image Module

0x9003

36867

Photo

Date​TimeOriginal

Ascii

The date and time when the original image data was generated. For a digital still camera the date and time the picture was taken are recorded.

(0008,0023), (0008,0033)

Content Date, Content Time

General Image Module

0x9004

36868

Photo

Date​TimeDigitized

Ascii

The date and time when the image was stored as digital data.

-

-

-

0x9101

37121

Photo

Components​Configuration

Undefined

Information specific to compressed data. The channels of each component are arranged in order from the 1st component to the 4th. For uncompressed data the data arrangement is given in the <Photometric​Interpretation> tag. However, since <Photometric​Interpretation> can only express the order of Y, Cb and Cr, this tag is provided for cases when compressed data uses components other than Y, Cb, and Cr and to enable support of other sequences.

-

-

-

0x9102

37122

Photo

Compressed​BitsPer​Pixel

Rational

Information specific to compressed data. The compression mode used for a compressed image is indicated in unit bits per pixel.

(0016,0021)

Shutter Speed Value

VL Photographic Acquisition Module

0x9201

37377

Photo

Shutter​SpeedValue

SRational

Shutter speed. The unit is the APEX (Additive System of Photographic Exposure) setting.

(0016,0022)

Aperture Value

VL Photographic Acquisition Module

0x9202

37378

Photo

Aperture​Value

Rational

The lens aperture. The unit is the APEX value.

(0016,0023)

Brightness Value

VL Photographic Acquisition Module

0x9203

37379

Photo

Brightness​Value

SRational

The value of brightness. The unit is the APEX value. Ordinarily it is given in the range of -99.99 to 99.99.

(0016,0024)

Exposure Bias Value

VL Photographic Acquisition Module

0x9204

37380

Photo

Exposure​BiasValue

SRational

The exposure bias. The units is the APEX value. Ordinarily it is given in the range of -99.99 to 99.99.

(0016,0025)

Max Aperture Value

VL Photographic Acquisition Module

0x9205

37381

Photo

Max​ApertureValue

Rational

The smallest F number of the lens. The unit is the APEX value. Ordinarily it is given in the range of 00.00 to 99.99, but it is not limited to this range.

(0016,0026)

Subject Distance

VL Photographic Acquisition Module

0x9206

37382

Photo

Subject​Distance

Rational

The distance to the subject, given in meters.

(0016,0027)

Metering Mode

VL Photographic Acquisition Module

0x9207

37383

Photo

Metering​Mode

Short

The metering mode.

(0016,0028)

Light Source

VL Photographic Acquisition Module

0x9208

37384

Photo

Light​Source

Short

The kind of light source.

(0016,0011), (0016,0012), (0016,0013), (0016,0014), (0016,0015)

Flash Firing Status, Flash Return Status, Flash Mode, Flash Function Present, Flash Red Eye Mode

VL Photographic Acquisition Module

0x9209

37385

Photo

Flash

Short

This tag is recorded when an image is taken using a strobe light (flash).

(0016,0029)

Focal Length

VL Photographic Acquisition Module

0x920a

37386

Photo

Focal​Length

Rational

The actual focal length of the lens, in mm. Conversion is not made to the focal length of a 35 mm film camera.

(0016,002A)

Subject Area

VL Photographic Acquisition Module

0x9214

37396

Photo

Subject​Area

Short

This tag indicates the location and area of the main subject in the overall scene.

(0016,002B)

Maker Note

VL Photographic Acquisition Module

0x927c

37500

Photo

Maker​Note

Undefined

A tag for manufacturers of Exif writers to record any desired information. The contents are up to the manufacturer.

(0020,4000)

Image Comments

General Image Module

0x9286

37510

Photo

User​Comment

Comment

A tag for Exif users to write keywords or comments on the image besides those in <Image​Description>, and without the character code limitations of the <Image​Description> tag. The character code used in the UserComment tag is identified based on an ID code in a fixed 8-byte area at the start of the tag data area.

-

-

VL Photographic Acquisition Module

0x9290

37520

Photo

Sub​SecTime

Ascii

A tag used to record fractions of seconds for the <Date​Time> tag.

(0008,002A)

Acquisition Date​Time

General Image Module

0x9291

37521

Photo

Sub​SecTime​Original

Ascii

A tag used to record fractions of seconds for the <Date​TimeOriginal> tag.

(0008,0033)

Content Time

General Image Module

0x9292

37522

Photo

Sub​SecTime​Digitized

Ascii

A tag used to record fractions of seconds for the <Date​TimeDigitized> tag.

-

-

-

0xa000

40960

Photo

Flashpix​Version

Undefined

The Flash​Pix format version supported by a FPXR file.

(0028,2002)

Color Space

Image Pixel Module

0xa001

40961

Photo

Color​Space

Short

The color space information tag is always recorded as the color space specifier. Normally sRGB is used to define the color space based on the PC monitor conditions and environment. If a color space other than sRGB is used, Uncalibrated is set. Image data recorded as Uncalibrated can be treated as sRGB when it is converted to Flash​Pix.

(0028,0011)

Columns

Image Pixel Module

0xa002

40962

Photo

PixelXDimension

Long

Information specific to compressed data. When a compressed file is recorded, the valid width of the meaningful image must be recorded in this tag, whether or not there is padding data or a restart marker. This tag should not exist in an uncompressed file.

(0028,0010)

Rows

Image Pixel Module

0xa003

40963

Photo

PixelYDimension

Long

Information specific to compressed data. When a compressed file is recorded, the valid height of the meaningful image must be recorded in this tag, whether or not there is padding data or a restart marker. This tag should not exist in an uncompressed file. Since data padding is unnecessary in the vertical direction, the number of lines recorded in this valid image height tag will in fact be the same as that recorded in the SOF.

-

-

-

0xa004

40964

Photo

Related​SoundFile

Ascii

This tag is used to record the name of an audio file related to the image data. The only relational information recorded here is the Exif audio file name and extension (an ASCII string consisting of 8 characters + '.' + 3 characters). The path is not recorded.

-

-

-

0xa005

40965

Photo

Interoperability​Tag

Long

Interoperability IFD is composed of tags which stores the information to ensure the Interoperability and pointed by the following tag located in Exif IFD. The Interoperability structure of Interoperability IFD is the same as TIFF defined IFD structure but does not contain the image data characteristically compared with normal TIFF IFD.

(0016,0036)

Flash Energy

VL Photographic Acquisition Module

0xa20b

41483

Photo

Flash​Energy

Rational

Indicates the strobe energy at the time the image is captured, as measured in Beam Candle Power Seconds (BCPS).

(0016,000A), (0016,000B), (0016,000C), (0016,000D)

Spatial Frequency Response Rows, Spatial Frequency Response Columns, Spatial Frequency Response Column Names, Spatial Frequency Response Values

VL Photographic Acquisition Module

0xa20c

41484

Photo

Spatial​FrequencyResponse

Undefined

This tag records the camera or input device spatial frequency table and SFR values in the direction of image width, image height, and diagonal direction, as specified in [ISO 12233].

(0018,1164)

Imager Pixel Spacing

VL Image Module

0xa20e

41486

Photo

Focal​PlaneXResolution

Rational

Indicates the number of pixels in the image width (X) direction per <Focal​PlaneResolution​Unit> on the camera focal plane.

(0018,1164)

Imager Pixel Spacing

VL Image Module

0xa20f

41487

Photo

Focal​PlaneYResolution

Rational

Indicates the number of pixels in the image height (V) direction per <Focal​PlaneResolution​Unit> on the camera focal plane.

(0018,1164)

Imager Pixel Spacing

VL Image Module

0xa210

41488

Photo

Focal​PlaneResolution​Unit

Short

Indicates the unit for measuring <Focal​PlaneXResolution> and <Focal​PlaneYResolution>. This value is the same as the <Resolution​Unit>.

(0016,0037)

Subject Location

VL Photographic Acquisition Module

0xa214

41492

Photo

Subject​Location

Short

Indicates the location of the main subject in the scene. The value of this tag represents the pixel at the center of the main subject relative to the left edge, prior to rotation processing as per the <Rotation> tag. The first value indicates the X column number and second indicates the Y row number.

(0016,0038)

Photographic Exposure Index

VL Photographic Acquisition Module

0xa215

41493

Photo

Exposure​Index

Rational

Indicates the exposure index selected on the camera or input device at the time the image is captured.

(0016,0039)

Sensing Method

VL Photographic Acquisition Module

0xa217

41495

Photo

Sensing​Method

Short

Indicates the image sensor type on the camera or input device.

(0016,003A)

File Source

VL Photographic Acquisition Module

0xa300

41728

Photo

File​Source

Undefined

Indicates the image source. If a DSC recorded the image, this tag value of this tag always be set to 3, indicating that the image was recorded on a DSC.

(0016,003B)

Scene Type

VL Photographic Acquisition Module

0xa301

41729

Photo

Scene​Type

Undefined

Indicates the type of scene. If a DSC recorded the image, this tag value must always be set to 1, indicating that the image was directly photographed.

(0016,000E), (0016,000F), (0016,0010)

Color Filter Array Pattern Rows, Color Filter Array Pattern Columns, Color Filter Array Pattern Values

VL Photographic Acquisition Module

0xa302

41730

Photo

CFAPattern

Undefined

Indicates the color filter array (CFA) geometric pattern of the image sensor when a one-chip color area sensor is used. It does not apply to all sensing methods.

(0016,0041)

Custom Rendered

VL Photographic Acquisition Module

0xa401

41985

Photo

Custom​Rendered

Short

This tag indicates the use of special processing on image data, such as rendering geared to output. When special processing is performed, the reader is expected to disable or minimize any further processing.

(0016,0042)

Exposure Mode

VL Photographic Acquisition Module

0xa402

41986

Photo

Exposure​Mode

Short

This tag indicates the exposure mode set when the image was shot. In auto-bracketing mode, the camera shoots a series of frames of the same scene at different exposure settings.

(0016,0043)

White Balance

VL Photographic Acquisition Module

0xa403

41987

Photo

White​Balance

Short

This tag indicates the white balance mode set when the image was shot.

(0016,0044)

Digital Zoom Ratio

VL Photographic Acquisition Module

0xa404

41988

Photo

Digital​ZoomRatio

Rational

This tag indicates the digital zoom ratio when the image was shot. If the numerator of the recorded value is 0, this indicates that digital zoom was not used.

(0016,0045)

Focal Length In 35mm​ Film

VL Photographic Acquisition Module

0xa405

41989

Photo

Focal​LengthIn35mm​Film

Short

This tag indicates the equivalent focal length assuming a 35mm film camera, in mm. A value of 0 means the focal length is unknown. Note that this tag differs from the <Focal​Length> tag.

(0016,0046)

Scene Capture Type

VL Photographic Acquisition Module

0xa406

41990

Photo

Scene​CaptureType

Short

This tag indicates the type of scene that was shot. It can also be used to record the mode in which the image was shot. Note that this differs from the <Scene​Type> tag.

(0016,0047)

Gain Control

VL Photographic Acquisition Module

0xa407

41991

Photo

Gain​Control

Short

This tag indicates the degree of overall image gain adjustment.

(0016,0048)

Contrast

VL Photographic Acquisition Module

0xa408

41992

Photo

Contrast

Short

This tag indicates the direction of contrast processing applied by the camera when the image was shot.

(0016,0049)

Saturation

VL Photographic Acquisition Module

0xa409

41993

Photo

Saturation

Short

This tag indicates the direction of saturation processing applied by the camera when the image was shot.

(0016,004A)

Sharpness

VL Photographic Acquisition Module

0xa40a

41994

Photo

Sharpness

Short

This tag indicates the direction of sharpness processing applied by the camera when the image was shot.

(0016,004B)

Device Setting Description

VL Photographic Acquisition Module

0xa40b

41995

Photo

Device​SettingDescription

Undefined

This tag indicates information on the picture-taking conditions of a particular camera model. The tag is used only to indicate the picture-taking conditions in the reader.

(0016,004C)

Subject Distance Range

VL Photographic Acquisition Module

0xa40c

41996

Photo

Subject​DistanceRange

Short

This tag indicates the distance to the subject.

(0008,0018)

SOP Instance UID

SOP Common Module

0xa420

42016

Photo

Image​UniqueID

Ascii

This tag indicates an identifier assigned uniquely to each image. It is recorded as an ASCII string equivalent to hexadecimal notation and 128-bit fixed length.

(0016,004D)

Camera Owner Name

VL Photographic Equipment Module

0xa430

42032

Photo

Camera​OwnerName

Ascii

This tag records the owner of a camera used in photography as an ASCII string.

(0018,1000)

Device Serial Number

General Equipment Module

0xa431

42033

Photo

Body​SerialNumber

Ascii

This tag records the serial number of the body of the camera that was used in photography as an ASCII string.

(0016,004E)

Lens Specification

VL Photographic Equipment Module

0xa432

42034

Photo

Lens​Specification

Rational

This tag notes minimum focal length, maximum focal length, minimum F number in the minimum focal length, and minimum F number in the maximum focal length, which are specification information for the lens that was used in photography. When the minimum F number is unknown, the notation is 0/0

(0016,004F)

Lens Make

VL Photographic Equipment Module

0xa433

42035

Photo

Lens​Make

Ascii

This tag records the lens manufactor as an ASCII string.

(0016,0050)

Lens Model

VL Photographic Equipment Module

0xa434

42036

Photo

Lens​Model

Ascii

This tag records the lens's model name and model number as an ASCII string.

(0016,0051)

Lens Serial Number

VL Photographic Equipment Module

0xa435

42037

Photo

Lens​SerialNumber

Ascii

This tag records the serial number of the interchangeable lens that was used in photography as an ASCII string.

(0016,0061)

Interoperability Index

VL Photographic Acquisition Module

0x0001

1

Iop

Interoperability​Index

Ascii

Indicates the identification of the Interoperability rule. Use "R98" for stating Exif​R98 Rules. Four bytes used including the termination code (NULL). see the separate volume of Recommended Exif Interoperability Rules (Exif​R98) for other tags used for Exif​R98.

(0016,0062)

Interoperability Version

VL Photographic Acquisition Module

0x0002

2

Iop

Interoperability​Version

Undefined

Interoperability version

-

-

-

0x1000

4096

Iop

Related​ImageFile​Format

Ascii

File format of image file

-

-

-

0x1001

4097

Iop

Related​ImageWidth

Long

Image width

-

-

-

0x1002

4098

Iop

Related​ImageLength

Long

Image height

-

-

-

0x000b

11

Image

Processing​Software

Ascii

The name and version of the software used to post-process the picture.

-

-

-

0x00fe

254

Image

New​SubfileType

Long

A general indication of the kind of data contained in this subfile.

-

-

-

0x00ff

255

Image

Subfile​Type

Short

A general indication of the kind of data contained in this subfile. This field is deprecated. The New​SubfileType field should be used instead.

(0028,0011)

Columns

Image Pixel Module

0x0100

256

Image

Image​Width

Long

The number of columns of image data, equal to the number of pixels per row. In JPEG compressed data a JPEG marker is used instead of this tag.

(0028,0010)

Rows

Image Pixel Module

0x0101

257

Image

Image​Length

Long

The number of rows of image data. In JPEG compressed data a JPEG marker is used instead of this tag.

(0028,0101)

Bits Stored

Image Pixel Module

0x0102

258

Image

Bits​PerSample

Short

The number of bits per image component. In this standard each component of the image is 8 bits, so the value for this tag is 8. See also <Samples​PerPixel>. In JPEG compressed data a JPEG marker is used instead of this tag.

(0002,0010)

Transfer Syntax UID

DICOM File Meta Information

0x0103

259

Image

Compression

Short

The compression scheme used for the image data. When a primary image is JPEG compressed, this designation is not necessary and is omitted. When thumbnails use JPEG compression, this tag value is set to 6.

(0028,0004)

Photometric Interpretation

Image Pixel Module

0x0106

262

Image

Photometric​Interpretation

Short

The pixel composition. In JPEG compressed data a JPEG marker is used instead of this tag.

-

-

-

0x0107

263

Image

Thresholding

Short

For black and white TIFF files that represent shades of gray, the technique used to convert from gray to black and white pixels.

-

-

-

0x0108

264

Image

Cell​Width

Short

The width of the dithering or halftoning matrix used to create a dithered or halftoned bilevel file.

-

-

-

0x0109

265

Image

Cell​Length

Short

The length of the dithering or halftoning matrix used to create a dithered or halftoned bilevel file.

-

-

-

0x010a

266

Image

Fill​Order

Short

The logical order of bits within a byte

(0042,0010)

Document Title

Encapsulated Document Module

0x010d

269

Image

Document​Name

Ascii

The name of the document from which this image was scanned

(0020,4000)

Image Comments

General Image Module

0x010e

270

Image

Image​Description

Ascii

A character string giving the title of the image. It may be a comment such as "1988 company picnic" or the like. Two-bytes character codes cannot be used. When a 2-bytes code is necessary, the Exif Private tag <User​Comment> is to be used.

(0008,0070)

Manufacturer

General Equipment Module

0x010f

271

Image

Make

Ascii

The manufacturer of the recording equipment. This is the manufacturer of the DSC, scanner, video digitizer or other equipment that generated the image. When the field is left blank, it is treated as unknown.

(0008,1090)

Manufacturer's Model Name

General Equipment Module

0x0110

272

Image

Model

Ascii

The model name or model number of the equipment. This is the model name or number of the DSC, scanner, video digitizer or other equipment that generated the image. When the field is left blank, it is treated as unknown.

-

-

-

0x0111

273

Image

Strip​Offsets

Long

For each strip, the byte offset of that strip. It is recommended that this be selected so the number of strip bytes does not exceed 64 Kbytes. With JPEG compressed data this designation is not needed and is omitted. See also <Rows​PerStrip> and <Strip​ByteCounts>.

-

-

-

0x0112

274

Image

Orientation

Short

The image orientation viewed in terms of rows and columns.

(0028,0002)

Samples Per Pixel

Image Pixel Module

0x0115

277

Image

Samples​PerPixel

Short

The number of components per pixel. Since this standard applies to RGB and YCb​Cr images, the value set for this tag is 3. In JPEG compressed data a JPEG marker is used instead of this tag.

-

-

-

0x0116

278

Image

Rows​PerStrip

Long

The number of rows per strip. This is the number of rows in the image of one strip when an image is divided into strips. With JPEG compressed data this designation is not needed and is omitted. See also <Strip​Offsets> and <Strip​ByteCounts>.

-

-

-

0x0117

279

Image

Strip​ByteCounts

Long

The total number of bytes in each strip. With JPEG compressed data this designation is not needed and is omitted.

(0028,0030)

Pixel Spacing

VL Image Module

0x011a

282

Image

XResolution

Rational

The number of pixels per <Resolution​Unit> in the <Image​Width> direction. When the image resolution is unknown, 72 [dpi] is designated.

(0028,0030)

Pixel Spacing

VL Image Module

0x011b

283

Image

YResolution

Rational

The number of pixels per <Resolution​Unit> in the <Image​Length> direction. The same value as <XResolution> is designated.

(0028,0006)

Planar Configuration

Image Pixel Module

0x011c

284

Image

Planar​Configuration

Short

Indicates whether pixel components are recorded in a chunky or planar format. In JPEG compressed files a JPEG marker is used instead of this tag. If this field does not exist, the TIFF default of 1 (chunky) is assumed.

-

-

-

0x0122

290

Image

Gray​ResponseUnit

Short

The precision of the information contained in the Gray​ResponseCurve.

-

-

-

0x0123

291

Image

Gray​ResponseCurve

Short

For grayscale data, the optical density of each possible pixel value.

-

-

-

0x0124

292

Image

T4​Options

Long

T.4-encoding options.

-

-

-

0x0125

293

Image

T6​Options

Long

T.6-encoding options.

(0028,0030)

Pixel Spacing

VL Image Module

0x0128

296

Image

Resolution​Unit

Short

The unit for measuring <XResolution> and <YResolution>. The same unit is used for both <XResolution> and <YResolution>. 2 = inches 3 = centimeters. If the image resolution is unknown, 2 (inches) is designated.

(0018,2001)

Page Number Vector

SC Multi-frame Vector Module

0x0129

297

Image

Page​Number

Short

The page number of the page from which this image was scanned.

-

-

-

0x012d

301

Image

Transfer​Function

Short

A transfer function for the image, described in tabular style. Normally this tag is not necessary, since color space is specified in the color space information tag (<Color​Space>).

(0018,1020)

Software Versions

General Equipment Module

0x0131

305

Image

Software

Ascii

This tag records the name and version of the software or firmware of the camera or image input device used to generate the image. The detailed format is not specified, but it is recommended that the example shown below be followed. When the field is left blank, it is treated as unknown.

(0x0008,0023), (0008,0023)

Content Date, Content Time

General Image Module

0x0132

306

Image

Date​Time

Ascii

The date and time of image creation. In Exif standard, it is the date and time the file was changed.

(0008,1070)

Operators' Name

General Series Module

0x013b

315

Image

Artist

Ascii

This tag records the name of the camera owner, photographer or image creator. The detailed format is not specified, but it is recommended that the information be written as in the example below for ease of Interoperability. When the field is left blank, it is treated as unknown. Ex.) "Camera owner, John Smith; Photographer, Michael Brown; Image creator, Ken James"

-

-

-

0x013c

316

Image

Host​Computer

Ascii

This tag records information about the host computer used to generate the image.

-

-

-

0x013d

317

Image

Predictor

Short

A predictor is a mathematical operator that is applied to the image data before an encoding scheme is applied.

(0016,0500)

White Point

VL Photographic Acquisition Module

0x013e

318

Image

White​Point

Rational

The chromaticity of the white point of the image. Normally this tag is not necessary, since color space is specified in the colorspace information tag (<Color​Space>).

(0016,0002)

Primary Chromaticities

VL Photographic Acquisition Module

0x013f

319

Image

Primary​Chromaticities

Rational

The chromaticity of the three primary colors of the image. Normally this tag is not necessary, since colorspace is specified in the colorspace information tag (<Color​Space>).

-

-

-

0x0140

320

Image

Color​Map

Short

A color map for palette color images. This field defines a Red-Green-Blue color map (often called a lookup table) for palette-color images. In a palette-color image, a pixel value is used to index into an RGB lookup table.

-

-

-

0x0141

321

Image

Halftone​Hints

Short

The purpose of the Halftone​Hints field is to convey to the halftone function the range of gray levels within a colorimetrically-specified image that should retain tonal detail.

-

-

-

0x0142

322

Image

Tile​Width

Short

The tile width in pixels. This is the number of columns in each tile.

-

-

-

0x0143

323

Image

Tile​Length

Short

The tile length (height) in pixels. This is the number of rows in each tile.

-

-

-

0x0144

324

Image

Tile​Offsets

Short

For each tile, the byte offset of that tile, as compressed and stored on disk. The offset is specified with respect to the beginning of the TIFF file. Note that this implies that each tile has a location independent of the locations of other tiles.

-

-

-

0x0145

325

Image

Tile​ByteCounts

Short

For each tile, the number of (compressed) bytes in that tile. See Tile​Offsets for a description of how the byte counts are ordered.

-

-

-

0x014a

330

Image

SubIFDs

Long

Defined by Adobe Corporation to enable TIFF Trees within a TIFF file.

-

-

-

0x014c

332

Image

Ink​Set

Short

The set of inks used in a separated (Photometric​Interpretation=5) image.

-

-

-

0x014d

333

Image

Ink​Names

Ascii

The name of each ink used in a separated (Photometric​Interpretation=5) image.

-

-

-

0x014e

334

Image

Number​OfInks

Short

The number of inks. Usually equal to Samples​PerPixel, unless there are extra samples.

-

-

-

0x0150

336

Image

Dot​Range

Byte

The component values that correspond to a 0% dot and 100% dot.

-

-

-

0x0151

337

Image

Target​Printer

Ascii

A description of the printing environment for which this separation is intended.

-

-

-

0x0152

338

Image

Extra​Samples

Short

Specifies that each pixel has m extra components whose interpretation is defined by one of the values listed below.

-

-

-

0x0153

339

Image

Sample​Format

Short

This field specifies how to interpret each data sample in a pixel.

-

-

-

0x0154

340

Image

SMin​SampleValue

Short

This field specifies the minimum sample value.

-

-

-

0x0155

341

Image

SMax​SampleValue

Short

This field specifies the maximum sample value.

-

-

-

0x0156

342

Image

Transfer​Range

Short

Expands the range of the Transfer​Function

-

-

-

0x0157

343

Image

Clip​Path

Byte

A TIFF Clip​Path is intended to mirror the essentials of Post​Script's path creation functionality.

-

-

-

0x0158

344

Image

XClip​PathUnits

SShort

The number of units that span the width of the image, in terms of integer Clip​Path coordinates.

-

-

-

0x0159

345

Image

YClip​PathUnits

SShort

The number of units that span the height of the image, in terms of integer Clip​Path coordinates.

-

-

-

0x015a

346

Image

Indexed

Short

Indexed images are images where the 'pixels' do not represent color values, but rather an index (usually 8-bit) into a separate color table, the Color​Map.

-

-

-

0x015b

347

Image

JPEGTables

Undefined

This optional tag may be used to encode the JPEG quantization and Huffman tables for subsequent use by the JPEG decompression process.

-

-

-

0x015f

351

Image

OPIProxy

Short

OPIProxy gives information concerning whether this image is a low-resolution proxy of a high-resolution image (Adobe OPI).

-

-

-

0x0200

512

Image

JPEGProc

Long

This field indicates the process used to produce the compressed data

-

-

-

0x0201

513

Image

JPEGInterchange​Format

Long

The offset to the start byte (SOI) of JPEG compressed thumbnail data. This is not used for primary image JPEG data.

-

-

-

0x0202

514

Image

JPEGInterchange​FormatLength

Long

The number of bytes of JPEG compressed thumbnail data. This is not used for primary image JPEG data. JPEG thumbnails are not divided but are recorded as a continuous JPEG bitstream from SOI to EOI. Appn and COM markers should not be recorded. Compressed thumbnails must be recorded in no more than 64 Kbytes, including all other data to be recorded in APP1.

-

-

-

0x0203

515

Image

JPEGRestart​Interval

Short

This Field indicates the length of the restart interval used in the compressed image data.

-

-

-

0x0205

517

Image

JPEGLossless​Predictors

Short

This Field points to a list of lossless predictor-selection values, one per component.

-

-

-

0x0206

518

Image

JPEGPoint​Transforms

Short

This Field points to a list of point transform values, one per component.

-

-

-

0x0207

519

Image

JPEGQTables

Long

This Field points to a list of offsets to the quantization tables, one per component.

-

-

-

0x0208

520

Image

JPEGDCTables

Long

This Field points to a list of offsets to the DC Huffman tables or the lossless Huffman tables, one per component.

-

-

-

0x0209

521

Image

JPEGACTables

Long

This Field points to a list of offsets to the Huffman AC tables, one per component.

-

-

-

0x0211

529

Image

YCb​CrCoefficients

Rational

The matrix coefficients for transformation from RGB to YCb​Cr image data. No default is given in TIFF; but here the value given in Appendix E, "Color Space Guidelines", is used as the default. The color space is declared in a color space information tag, with the default being the value that gives the optimal image characteristics Interoperability this condition.

-

-

-

0x0212

530

Image

YCb​CrSub​Sampling

Short

The sampling ratio of chrominance components in relation to the luminance component. In JPEG compressed data a JPEG marker is used instead of this tag.

-

-

-

0x0213

531

Image

YCb​CrPositioning

Short

The position of chrominance components in relation to the luminance component. This field is designated only for JPEG compressed data or uncompressed YCb​Cr data. The TIFF default is 1 (centered); but when Y:Cb:Cr = 4:2:2 it is recommended in this standard that 2 (co-sited) be used to record data, in order to improve the image quality when viewed on TV systems. When this field does not exist, the reader shall assume the TIFF default. In the case of Y:Cb:Cr = 4:2:0, the TIFF default (centered) is recommended. If the reader does not have the capability of supporting both kinds of <YCb​CrPositioning>, it shall follow the TIFF default regardless of the value in this field. It is preferable that readers be able to support both centered and co-sited positioning.

-

-

-

0x0214

532

Image

Reference​BlackWhite

Rational

The reference black point value and reference white point value. No defaults are given in TIFF, but the values below are given as defaults here. The color space is declared in a color space information tag, with the default being the value that gives the optimal image characteristics Interoperability these conditions.

-

-

-

0x02bc

700

Image

XMLPacket

Byte

XMP Metadata (Adobe technote 9-14-02)

-

-

-

0x4746

18246

Image

Rating

Short

Rating tag used by Windows

-

-

-

0x4749

18249

Image

Rating​Percent

Short

Rating tag used by Windows, value in percent

-

-

-

0x800d

32781

Image

ImageID

Ascii

ImageID is the full pathname of the original, high-resolution image, or any other identifying string that uniquely identifies the original image (Adobe OPI).

-

-

-

0x828d

33421

Image

CFARepeat​PatternDim

Short

Contains two values representing the minimum rows and columns to define the repeating patterns of the color filter array

-

-

-

0x828e

33422

Image

CFAPattern

Byte

Indicates the color filter array (CFA) geometric pattern of the image sensor when a one-chip color area sensor is used. It does not apply to all sensing methods. [Not EXIF but TIFF/EP]

(0016,0003)

Battery Level

VL Photographic Acquisition Module

0x828f

33423

Image

Battery​Level

Rational

Contains a value of the battery level as a fraction or string

-

-

-

0x8298

33432

Image

Copyright

Ascii

Copyright information. In this standard the tag is used to indicate both the photographer and editor copyrights. It is the copyright notice of the person or organization claiming rights to the image. The Interoperability copyright statement including date and rights should be written in this field; e.g., "Copyright, John Smith, 19xx. All rights reserved.". In this standard the field records both the photographer and editor copyrights, with each recorded in a separate part of the statement. When there is a clear distinction between the photographer and editor copyrights, these are to be written in the order of photographer followed by editor copyright, separated by NULL (in this case since the statement also ends with a NULL, there are two NULL codes). When only the photographer copyright is given, it is terminated by one NULL code. When only the editor copyright is given, the photographer copyright part consists of one space followed by a terminating NULL code, then the editor copyright is given. When the field is left blank, it is treated as unknown.

-

-

-

0x83bb

33723

Image

IPTCNAA

Long

Contains an IPTC/NAA record

-

-

-

0x8649

34377

Image

Image​Resources

Byte

Contains information embedded by the Adobe Photoshop application

-

-

-

0x8769

34665

Image

Exif​Tag

Long

A pointer to the Exif IFD. Interoperability, Exif IFD has the same structure as that of the IFD specified in TIFF. ordinarily, however, it does not contain image data as in the case of TIFF.

(0028,2000)

ICC Profile

Image Pixel Module

ICC Profile Module

0x8773

34675

Image

Inter​ColorProfile

Undefined

Contains an Inter[national ]​Color Consortium (ICC) format color space characterization/profile

-

-

-

0x8825

34853

Image

GPSTag

Long

A pointer to the GPS Info IFD. The Interoperability structure of the GPS Info IFD, like that of Exif IFD, has no image data.

-

-

-

0x8829

34857

Image

Interlace

Short

Indicates the field number of multifield images.

(0008,0201)

Timezone Offset From UTC

SOP Common Module

0x882a

34858

Image

Time​ZoneOffset

SShort

This optional tag encodes the time zone of the camera clock (relativeto Greenwich Mean Time) used to create the Data​TimeOriginal tag-valuewhen the picture was taken. It may also contain the time zone offsetof the clock used to create the Date​Time tag-value when the image was modified. [TIFF/EP]

(0016,0019)

Self Timer Mode

VL Photographic Acquisition Module

0x882b

34859

Image

Self​TimerMode

Short

Number of seconds image capture was delayed from button press.

(0016,0036)

Flash Energy

VL Photographic Acquisition Module

0x920b

37387

Image

Flash​Energy

Rational

Amount of flash energy (BCPS). [TIFF/EP]

(0016,000A), (0016,000B), (0016,000C), (0016,000D)

Spatial Frequency Response Rows, Spatial Frequency Response Columns, Spatial Frequency Response Column Names, Spatial Frequency Response Values

VL Photographic Acquisition Module

0x920c

37388

Image

Spatial​FrequencyResponse

Undefined

SFR of the camera. [TIFF/EP]

-

-

-

0x920d

37389

Image

Noise

Undefined

Noise measurement values.

(0018,1164)

Imager Pixel Spacing

VL Image Module

0x920e

37390

Image

Focal​PlaneXResolution

Rational

Number of pixels per Focal​PlaneResolution​Unit (37392) in Image​Width direction for main image. [TIFF/EP]

(0018,1164)

Imager Pixel Spacing

VL Image Module

0x920f

37391

Image

Focal​PlaneYResolution

Rational

Number of pixels per Focal​PlaneResolution​Unit (37392) in Image​Length direction for main image. [TIFF/EP]

(0018,1164)

Imager Pixel Spacing

VL Image Module

0x9210

37392

Image

Focal​PlaneResolution​Unit

Short

Unit of measurement for Focal​PlaneXResolution(37390) and Focal​PlaneYResolution(37391). [TIFF/EP]

(0020,0013)

Instance Number

General Image Module

0x9211

37393

Image

Image​Number

Long

Number assigned to an image, e.g., in a chained image burst.

-

-

-

0x9212

37394

Image

Security​Classification

Ascii

Security classification assigned to the image.

-

-

-

0x9213

37395

Image

Image​History

Ascii

Record of what has been done to the image.

(0016,0037)

Subject Location

VL Photographic Acquisition Module

0x9214

37396

Image

Subject​Location

Short

Indicates the location and area of the main subject in the overall scene. [TIFF/EP]

(0016,0038)

Photographic Exposure Index

VL Photographic Acquisition Module

0x9215

37397

Image

Exposure​Index

Rational

Encodes the camera exposure index setting when image was captured. [Not EXIF but TIFF/EP]

-

-

-

0x9216

37398

Image

TIFFEPStandardID

Byte

Contains four ASCII characters representing the TIFF/EP standard version of a TIFF/EP file, eg '1', '0', '0', '0'

(0016,0039)

Sensing Method

VL Photographic Acquisition Module

0x9217

37399

Image

Sensing​Method

Short

Type of image sensor. [TIFF/EP]

-

-

-

0x9c9b

40091

Image

XPTitle

Byte

Title tag used by Windows, encoded in UCS2

-

-

-

0x9c9c

40092

Image

XPComment

Byte

Comment tag used by Windows, encoded in UCS2

-

-

-

0x9c9d

40093

Image

XPAuthor

Byte

Author tag used by Windows, encoded in UCS2

-

-

-

0x9c9e

40094

Image

XPKeywords

Byte

Keywords tag used by Windows, encoded in UCS2

-

-

-

0x9c9f

40095

Image

XPSubject

Byte

Subject tag used by Windows, encoded in UCS2

0xc4a5

50341

Image

Print​ImageMatching

Undefined

Print Image Matching, description needed.

0xc612

50706

Image

DNGVersion

Byte

This tag encodes the DNG four-tier version number. For files compliant with version 1.1.0.0 of the DNG specification, this tag should contain the bytes: 1, 1, 0, 0.

0xc613

50707

Image

DNGBackward​Version

Byte

This tag specifies the oldest version of the Digital Negative specification for which a file is compatible. Readers should not attempt to read a file if this tag specifies a version number that is higher than the version number of the specification the reader was based on. In addition to checking the version tags, readers should, for all tags, check the types, counts, and values, to verify it is able to correctly read the file.

0xc614

50708

Image

Unique​CameraModel

Ascii

Defines a unique, non-localized name for the camera model that created the image in the raw file. This name should include the manufacturer's name to avoid conflicts, and should not be localized, even if the camera name itself is localized for different markets (see Localized​CameraModel). This string may be used by reader software to index into per-model preferences and replacement profiles.

0xc615

50709

Image

Localized​CameraModel

Byte

Similar to the Unique​CameraModel field, except the name can be localized for different markets to match the localization of the camera name.

0xc616

50710

Image

CFAPlane​Color

Byte

Provides a mapping between the values in the CFAPattern tag and the plane numbers in Linear​Raw space. This is a required tag for non-RGB CFA images.

0xc617

50711

Image

CFALayout

Short

Describes the spatial layout of the CFA.

0xc618

50712

Image

Linearization​Table

Short

Describes a lookup table that maps stored values into linear values. This tag is typically used to increase compression ratios by storing the raw data in a non-linear, more visually uniform space with fewer total encoding levels. If Samples​PerPixel is not equal to one, this single table applies to all the samples for each pixel.

0xc619

50713

Image

Black​LevelRepeat​Dim

Short

Specifies repeat pattern size for the Black​Level tag.

0xc61a

50714

Image

Black​Level

Rational

Specifies the zero light (a.k.a. thermal black or black current) encoding level, as a repeating pattern. The origin of this pattern is the top-left corner of the Active​Area rectangle. The values are stored in row-column-sample scan order.

0xc61b

50715

Image

Black​LevelDeltaH

SRational

If the zero light encoding level is a function of the image column, Black​LevelDeltaH specifies the difference between the zero light encoding level for each column and the baseline zero light encoding level. If Samples​PerPixel is not equal to one, this single table applies to all the samples for each pixel.

0xc61c

50716

Image

Black​LevelDeltaV

SRational

If the zero light encoding level is a function of the image row, this tag specifies the difference between the zero light encoding level for each row and the baseline zero light encoding level. If Samples​PerPixel is not equal to one, this single table applies to all the samples for each pixel.

0xc61d

50717

Image

White​Level

Short

This tag specifies the fully saturated encoding level for the raw sample values. Saturation is caused either by the sensor itself becoming highly non-linear in response, or by the camera's analog to digital converter clipping.

0xc61e

50718

Image

Default​Scale

Rational

Default​Scale is required for cameras with non-square pixels. It specifies the default scale factors for each direction to convert the image to square pixels. Typically these factors are selected to approximately preserve total pixel count. For CFA images that use CFALayout equal to 2, 3, 4, or 5, such as the Fujifilm SuperCCD, these two values should usually differ by a factor of 2.0.

0xc61f

50719

Image

Default​CropOrigin

Short

Raw images often store extra pixels around the edges of the final image. These extra pixels help prevent interpolation artifacts near the edges of the final image. Default​CropOrigin specifies the origin of the final image area, in raw image coordinates (i.e., before the Default​Scale has been applied), relative to the top-left corner of the Active​Area rectangle.

0xc620

50720

Image

Default​CropSize

Short

Raw images often store extra pixels around the edges of the final image. These extra pixels help prevent interpolation artifacts near the edges of the final image. Default​CropSize specifies the size of the final image area, in raw image coordinates (i.e., before the Default​Scale has been applied).

0xc621

50721

Image

Color​Matrix1

SRational

Color​Matrix1 defines a transformation matrix that converts XYZ values to reference camera native color space values, under the first calibration illuminant. The matrix values are stored in row scan order. The Color​Matrix1 tag is required for all non-monochrome DNG files.

0xc622

50722

Image

Color​Matrix2

SRational

Color​Matrix2 defines a transformation matrix that converts XYZ values to reference camera native color space values, under the second calibration illuminant. The matrix values are stored in row scan order.

0xc623

50723

Image

Camera​Calibration1

SRational

Camera​Calibration1 defines a calibration matrix that transforms reference camera native space values to individual camera native space values under the first calibration illuminant. The matrix is stored in row scan order. This matrix is stored separately from the matrix specified by the Color​Matrix1 tag to allow raw converters to swap in replacement color matrices based on Unique​CameraModel tag, while still taking advantage of any per-individual camera calibration performed by the camera manufacturer.

0xc624

50724

Image

Camera​Calibration2

SRational

Camera​Calibration2 defines a calibration matrix that transforms reference camera native space values to individual camera native space values under the second calibration illuminant. The matrix is stored in row scan order. This matrix is stored separately from the matrix specified by the Color​Matrix2 tag to allow raw converters to swap in replacement color matrices based on Unique​CameraModel tag, while still taking advantage of any per-individual camera calibration performed by the camera manufacturer.

0xc625

50725

Image

Reduction​Matrix1

SRational

Reduction​Matrix1 defines a dimensionality reduction matrix for use as the first stage in converting color camera native space values to XYZ values, under the first calibration illuminant. This tag may only be used if Color​Planes is greater than 3. The matrix is stored in row scan order.

0xc626

50726

Image

Reduction​Matrix2

SRational

Reduction​Matrix2 defines a dimensionality reduction matrix for use as the first stage in converting color camera native space values to XYZ values, under the second calibration illuminant. This tag may only be used if Color​Planes is greater than 3. The matrix is stored in row scan order.

0xc627

50727

Image

Analog​Balance

Rational

Normally the stored raw values are not white balanced, since any digital white balancing will reduce the dynamic range of the final image if the user decides to later adjust the white balance; however, if camera hardware is capable of white balancing the color channels before the signal is digitized, it can improve the dynamic range of the final image. Analog​Balance defines the gain, either analog (recommended) or digital (not recommended) that has been applied the stored raw values.

0xc628

50728

Image

As​ShotNeutral

Short

Specifies the selected white balance at time of capture, encoded as the coordinates of a perfectly neutral color in linear reference space values. The inclusion of this tag precludes the inclusion of the As​ShotWhiteXY tag.

0xc629

50729

Image

As​ShotWhiteXY

Rational

Specifies the selected white balance at time of capture, encoded as x-y chromaticity coordinates. The inclusion of this tag precludes the inclusion of the As​ShotNeutral tag.

0xc62a

50730

Image

Baseline​Exposure

SRational

Camera models vary in the trade-off they make between highlight headroom and shadow noise. Some leave a significant amount of highlight headroom during a normal exposure. This allows significant negative exposure compensation to be applied during raw conversion, but also means normal exposures will contain more shadow noise. Other models leave less headroom during normal exposures. This allows for less negative exposure compensation, but results in lower shadow noise for normal exposures. Because of these differences, a raw converter needs to vary the zero point of its exposure compensation control from model to model. Baseline​Exposure specifies by how much (in EV units) to move the zero point. Positive values result in brighter default results, while negative values result in darker default results.

0xc62b

50731

Image

Baseline​Noise

Rational

Specifies the relative noise level of the camera model at a baseline ISO value of 100, compared to a reference camera model. Since noise levels tend to vary approximately with the square root of the ISO value, a raw converter can use this value, combined with the current ISO, to estimate the relative noise level of the current image.

0xc62c

50732

Image

Baseline​Sharpness

Rational

Specifies the relative amount of sharpening required for this camera model, compared to a reference camera model. Camera models vary in the strengths of their anti-aliasing filters. Cameras with weak or no filters require less sharpening than cameras with strong anti-aliasing filters.

0xc62d

50733

Image

Bayer​GreenSplit

Long

Only applies to CFA images using a Bayer pattern filter array. This tag specifies, in arbitrary units, how closely the values of the green pixels in the blue/green rows track the values of the green pixels in the red/green rows. A value of zero means the two kinds of green pixels track closely, while a non-zero value means they sometimes diverge. The useful range for this tag is from 0 (no divergence) to about 5000 (quite large divergence).

0xc62e

50734

Image

Linear​ResponseLimit

Rational

Some sensors have an unpredictable non-linearity in their response as they near the upper limit of their encoding range. This non-linearity results in color shifts in the highlight areas of the resulting image unless the raw converter compensates for this effect. Linear​ResponseLimit specifies the fraction of the encoding range above which the response may become significantly non-linear.

0xc62f

50735

Image

Camera​SerialNumber

Ascii

Camera​SerialNumber contains the serial number of the camera or camera body that captured the image.

0xc630

50736

Image

Lens​Info

Rational

Contains information about the lens that captured the image. If the minimum f-stops are unknown, they should be encoded as 0/0.

0xc631

50737

Image

Chroma​BlurRadius

Rational

Chroma​BlurRadius provides a hint to the DNG reader about how much chroma blur should be applied to the image. If this tag is omitted, the reader will use its default amount of chroma blurring. Normally this tag is only included for non-CFA images, since the amount of chroma blur required for mosaic images is highly dependent on the de-mosaic algorithm, in which case the DNG reader's default value is likely optimized for its particular de-mosaic algorithm.

0xc632

50738

Image

Anti​AliasStrength

Rational

Provides a hint to the DNG reader about how strong the camera's anti-alias filter is. A value of 0.0 means no anti-alias filter (i.e., the camera is prone to aliasing artifacts with some subjects), while a value of 1.0 means a strong anti-alias filter (i.e., the camera almost never has aliasing artifacts).

0xc633

50739

Image

Shadow​Scale

SRational

This tag is used by Adobe Camera Raw to control the sensitivity of its 'Shadows' slider.

0xc634

50740

Image

DNGPrivate​Data

Byte

Provides a way for camera manufacturers to store private data in the DNG file for use by their own raw converters, and to have that data preserved by programs that edit DNG files.

-

-

-

0xc635

50741

Image

Maker​NoteSafety

Short

Maker​NoteSafety lets the DNG reader know whether the EXIF Maker​Note tag is safe to preserve along with the rest of the EXIF data. File browsers and other image management software processing an image with a preserved Maker​Note should be aware that any thumbnail image embedded in the Maker​Note may be stale, and may not reflect the current state of the full size image.

0xc65a

50778

Image

Calibration​Illuminant1

Short

The illuminant used for the first set of color calibration tags (Color​Matrix1, Camera​Calibration1, Reduction​Matrix1). The legal values for this tag are the same as the legal values for the Light​Source EXIF tag.

0xc65b

50779

Image

Calibration​Illuminant2

Short

The illuminant used for an optional second set of color calibration tags (Color​Matrix2, Camera​Calibration2, Reduction​Matrix2). The legal values for this tag are the same as the legal values for the Calibration​Illuminant1 tag; however, if both are included, neither is allowed to have a value of 0 (unknown).

0xc65c

50780

Image

Best​QualityScale

Rational

For some cameras, the best possible image quality is not achieved by preserving the total pixel count during conversion. For example, Fujifilm SuperCCD images have maximum detail when their total pixel count is doubled. This tag specifies the amount by which the values of the Default​Scale tag need to be multiplied to achieve the best quality image size.

0xc65d

50781

Image

Raw​DataUniqueID

Byte

This tag contains a 16-byte unique identifier for the raw image data in the DNG file. DNG readers can use this tag to recognize a particular raw image, even if the file's name or the metadata contained in the file has been changed. If a DNG writer creates such an identifier, it should do so using an algorithm that will ensure that it is very unlikely two different images will end up having the same identifier.

-

-

-

0xc68b

50827

Image

Original​RawFile​Name

Byte

If the DNG file was converted from a non-DNG raw file, then this tag contains the file name of that original raw file.

-

-

-

0xc68c

50828

Image

Original​RawFile​Data

Undefined

If the DNG file was converted from a non-DNG raw file, then this tag contains the compressed contents of that original raw file. The contents of this tag always use the big-endian byte order. The tag contains a sequence of data blocks. Future versions of the DNG specification may define additional data blocks, so DNG readers should ignore extra bytes when parsing this tag. DNG readers should also detect the case where data blocks are missing from the end of the sequence, and should assume a default value for all the missing blocks. There are no padding or alignment bytes between data blocks.

0xc68d

50829

Image

Active​Area

Short

This rectangle defines the active (non-masked) pixels of the sensor. The order of the rectangle coordinates is: top, left, bottom, right.

0xc68e

50830

Image

Masked​Areas

Short

This tag contains a list of non-overlapping rectangle coordinates of fully masked pixels, which can be optionally used by DNG readers to measure the black encoding level. The order of each rectangle's coordinates is: top, left, bottom, right. If the raw image data has already had its black encoding level subtracted, then this tag should not be used, since the masked pixels are no longer useful.

0xc68f

50831

Image

As​ShotICCProfile

Undefined

This tag contains an ICC profile that, in conjunction with the As​ShotPre​ProfileMatrix tag, provides the camera manufacturer with a way to specify a default color rendering from camera color space coordinates (linear reference values) into the ICC profile connection space. The ICC profile connection space is an output referred colorimetric space, whereas the other color calibration tags in DNG specify a conversion into a scene referred colorimetric space. This means that the rendering in this profile should include any desired tone and gamut mapping needed to convert between scene referred values and output referred values.

0xc690

50832

Image

As​ShotPre​ProfileMatrix

SRational

This tag is used in conjunction with the As​ShotICCProfile tag. It specifies a matrix that should be applied to the camera color space coordinates before processing the values through the ICC profile specified in the As​ShotICCProfile tag. The matrix is stored in the row scan order. If Color​Planes is greater than three, then this matrix can (but is not required to) reduce the dimensionality of the color data down to three components, in which case the As​ShotICCProfile should have three rather than Color​Planes input components.

0xc691

50833

Image

CurrentICCProfile

Undefined

This tag is used in conjunction with the Current​PreProfile​Matrix tag. The CurrentICCProfile and Current​PreProfile​Matrix tags have the same purpose and usage as the As​ShotICCProfile and As​ShotPre​ProfileMatrix tag pair, except they are for use by raw file editors rather than camera manufacturers.

0xc692

50834

Image

Current​PreProfile​Matrix

SRational

This tag is used in conjunction with the CurrentICCProfile tag. The CurrentICCProfile and Current​PreProfile​Matrix tags have the same purpose and usage as the As​ShotICCProfile and As​ShotPre​ProfileMatrix tag pair, except they are for use by raw file editors rather than camera manufacturers.

0xc6bf

50879

Image

Colorimetric​Reference

Short

The DNG color model documents a transform between camera colors and CIE XYZ values. This tag describes the colorimetric reference for the CIE XYZ values. 0 = The XYZ values are scene-referred. 1 = The XYZ values are output-referred, using the ICC profile perceptual dynamic range. This tag allows output-referred data to be stored in DNG files and still processed correctly by DNG readers.

0xc6f3

50931

Image

Camera​CalibrationSignature

Byte

A UTF-8 encoded string associated with the Camera​Calibration1 and Camera​Calibration2 tags. The Camera​Calibration1 and Camera​Calibration2 tags should only be used in the DNG color transform if the string stored in the Camera​CalibrationSignature tag exactly matches the string stored in the Profile​CalibrationSignature tag for the selected camera profile.

0xc6f4

50932

Image

Profile​CalibrationSignature

Byte

A UTF-8 encoded string associated with the camera profile tags. The Camera​Calibration1 and Camera​Calibration2 tags should only be used in the DNG color transfer if the string stored in the Camera​CalibrationSignature tag exactly matches the string stored in the Profile​CalibrationSignature tag for the selected camera profile.

0xc6f6

50934

Image

As​ShotProfile​Name

Byte

A UTF-8 encoded string containing the name of the "as shot" camera profile, if any.

0xc6f7

50935

Image

Noise​ReductionApplied

Rational

This tag indicates how much noise reduction has been applied to the raw data on a scale of 0.0 to 1.0. A 0.0 value indicates that no noise reduction has been applied. A 1.0 value indicates that the "ideal" amount of noise reduction has been applied, i.e. that the DNG reader should not apply additional noise reduction by default. A value of 0/0 indicates that this parameter is unknown.

0xc6f8

50936

Image

Profile​Name

Byte

A UTF-8 encoded string containing the name of the camera profile. This tag is optional if there is only a single camera profile stored in the file but is required for all camera profiles if there is more than one camera profile stored in the file.

0xc6f9

50937

Image

Profile​HueSat​MapDims

Long

This tag specifies the number of input samples in each dimension of the hue/saturation/value mapping tables. The data for these tables are stored in Profile​HueSat​MapData1 and Profile​HueSat​MapData2 tags. The most common case has Value​Divisions equal to 1, so only hue and saturation are used as inputs to the mapping table.

0xc6fa

50938

Image

Profile​HueSat​MapData1

Float

This tag contains the data for the first hue/saturation/value mapping table. Each entry of the table contains three 32-bit IEEE floating-point values. The first entry is hue shift in degrees; the second entry is saturation scale factor; and the third entry is a value scale factor. The table entries are stored in the tag in nested loop order, with the value divisions in the outer loop, the hue divisions in the middle loop, and the saturation divisions in the inner loop. All zero input saturation entries are required to have a value scale factor of 1.0.

0xc6fb

50939

Image

Profile​HueSat​MapData2

Float

This tag contains the data for the second hue/saturation/value mapping table. Each entry of the table contains three 32-bit IEEE floating-point values. The first entry is hue shift in degrees; the second entry is a saturation scale factor; and the third entry is a value scale factor. The table entries are stored in the tag in nested loop order, with the value divisions in the outer loop, the hue divisions in the middle loop, and the saturation divisions in the inner loop. All zero input saturation entries are required to have a value scale factor of 1.0.

0xc6fc

50940

Image

Profile​ToneCurve

Float

This tag contains a default tone curve that can be applied while processing the image as a starting point for user adjustments. The curve is specified as a list of 32-bit IEEE floating-point value pairs in linear gamma. Each sample has an input value in the range of 0.0 to 1.0, and an output value in the range of 0.0 to 1.0. The first sample is required to be (0.0, 0.0), and the last sample is required to be (1.0, 1.0). Interpolated the curve using a cubic spline.

0xc6fd

50941

Image

Profile​EmbedPolicy

Long

This tag contains information about the usage rules for the associated camera profile.

0xc6fe

50942

Image

Profile​Copyright

Byte

A UTF-8 encoded string containing the copyright information for the camera profile. This string always should be preserved along with the other camera profile tags.

0xc714

50964

Image

Forward​Matrix1

SRational

This tag defines a matrix that maps white balanced camera colors to XYZ D50 colors.

0xc715

50965

Image

Forward​Matrix2

SRational

This tag defines a matrix that maps white balanced camera colors to XYZ D50 colors.

-

-

-

0xc716

50966

Image

Preview​ApplicationName

Byte

A UTF-8 encoded string containing the name of the application that created the preview stored in the IFD.

-

-

-

0xc717

50967

Image

Preview​ApplicationVersion

Byte

A UTF-8 encoded string containing the version number of the application that created the preview stored in the IFD.

-

-

-

0xc718

50968

Image

Preview​SettingsName

Byte

A UTF-8 encoded string containing the name of the conversion settings (for example, snapshot name) used for the preview stored in the IFD.

-

-

-

0xc719

50969

Image

Preview​SettingsDigest

Byte

A unique ID of the conversion settings (for example, MD5 digest) used to render the preview stored in the IFD.

-

-

-

0xc71a

50970

Image

Preview​ColorSpace

Long

This tag specifies the color space in which the rendered preview in this IFD is stored. The default value for this tag is sRGB for color previews and Gray Gamma 2.2 for monochrome previews.

-

-

-

0xc71b

50971

Image

Preview​DateTime

Ascii

This tag is an ASCII string containing the name of the date/time at which the preview stored in the IFD was rendered. The date/time is encoded using ISO 8601 format.

-

-

-

0xc71c

50972

Image

Raw​ImageDigest

Undefined

This tag is an MD5 digest of the raw image data. All pixels in the image are processed in row-scan order. Each pixel is zero padded to 16 or 32 bits deep (16-bit for data less than or equal to 16 bits deep, 32-bit otherwise). The data for each pixel is processed in little-endian byte order.

-

-

-

0xc71d

50973

Image

Original​RawFile​Digest

Undefined

This tag is an MD5 digest of the data stored in the Original​RawFile​Data tag.

0xc71e

50974

Image

Sub​TileBlock​Size

Long

Normally, the pixels within a tile are stored in simple row-scan order. This tag specifies that the pixels within a tile should be grouped first into rectangular blocks of the specified size. These blocks are stored in row-scan order. Within each block, the pixels are stored in row-scan order. The use of a non-default value for this tag requires setting the DNGBackward​Version tag to at least 1.2.0.0.

0xc71f

50975

Image

Row​InterleaveFactor

Long

This tag specifies that rows of the image are stored in interleaved order. The value of the tag specifies the number of interleaved fields. The use of a non-default value for this tag requires setting the DNGBackward​Version tag to at least 1.2.0.0.

0xc725

50981

Image

Profile​LookTable​Dims

Long

This tag specifies the number of input samples in each dimension of a default "look" table. The data for this table is stored in the Profile​LookTable​Data tag.

0xc726

50982

Image

Profile​LookTable​Data

Float

This tag contains a default "look" table that can be applied while processing the image as a starting point for user adjustment. This table uses the same format as the tables stored in the Profile​HueSat​MapData1 and Profile​HueSat​MapData2 tags, and is applied in the same color space. However, it should be applied later in the processing pipe, after any exposure compensation and/or fill light stages, but before any tone curve stage. Each entry of the table contains three 32-bit IEEE floating-point values. The first entry is hue shift in degrees, the second entry is a saturation scale factor, and the third entry is a value scale factor. The table entries are stored in the tag in nested loop order, with the value divisions in the outer loop, the hue divisions in the middle loop, and the saturation divisions in the inner loop. All zero input saturation entries are required to have a value scale factor of 1.0.

0xc740

51008

Image

Opcode​List1

Undefined

Specifies the list of opcodes that should be applied to the raw image, as read directly from the file.

0xc741

51009

Image

Opcode​List2

Undefined

Specifies the list of opcodes that should be applied to the raw image, just after it has been mapped to linear reference values.

0xc74e

51022

Image

Opcode​List3

Undefined

Specifies the list of opcodes that should be applied to the raw image, just after it has been demosaiced.

0xc761

51041

Image

Noise​Profile

Double

Noise​Profile describes the amount of noise in a raw image. Specifically, this tag models the amount of signal-dependent photon (shot) noise and signal-independent sensor readout noise, two common sources of noise in raw images. The model assumes that the noise is white and spatially independent, ignoring fixed pattern effects and other sources of noise (e.g., pixel response non-uniformity, spatially-dependent thermal effects, etc.).

(0016,0070)

GPS Version ID

VL Photographic Geolocation Module

0x0000

0

GPSInfo

GPSVersionID

Byte

Indicates the version of <GPSInfoIFD>. The version is given as 2.0.0.0. This tag is mandatory when <GPSInfo> tag is present. (Note: The <GPSVersionID> tag is given in bytes, unlike the <Exif​Version> tag. When the version is 2.0.0.0, the tag value is 02000000.H).

(0016,0071)

GPS Latitude​ Ref

VL Photographic Geolocation Module

0x0001

1

GPSInfo

GPSLatitude​Ref

Ascii

Indicates whether the latitude is north or south latitude. The ASCII value 'N' indicates north latitude, and 'S' is south latitude.

(0016,0072)

GPS Latitude​

VL Photographic Geolocation Module

0x0002

2

GPSInfo

GPSLatitude

Rational

Indicates the latitude. The latitude is expressed as three RATIONAL values giving the degrees, minutes, and seconds, respectively. When degrees, minutes and seconds are expressed, the format is dd/1,mm/1,ss/1. When degrees and minutes are used and, for example, fractions of minutes are given up to two decimal places, the format is dd/1,mmmm/100,0/1.

(0016,0073)

GPS Longitude Ref

VL Photographic Geolocation Module

0x0003

3

GPSInfo

GPSLongitude​Ref

Ascii

Indicates whether the longitude is east or west longitude. ASCII 'E' indicates east longitude, and 'W' is west longitude.

(0016,0074)

GPS Longitude

VL Photographic Geolocation Module

0x0004

4

GPSInfo

GPSLongitude

Rational

Indicates the longitude. The longitude is expressed as three RATIONAL values giving the degrees, minutes, and seconds, respectively. When degrees, minutes and seconds are expressed, the format is ddd/1,mm/1,ss/1. When degrees and minutes are used and, for example, fractions of minutes are given up to two decimal places, the format is ddd/1,mmmm/100,0/1.

(0016,0075)

GPS Altitude​ Ref

VL Photographic Geolocation Module

0x0005

5

GPSInfo

GPSAltitude​Ref

Byte

Indicates the altitude used as the reference altitude. If the reference is sea level and the altitude is above sea level, 0 is given. If the altitude is below sea level, a value of 1 is given and the altitude is indicated as an absolute value in the GSPAltitude tag. The reference unit is meters. Note that this tag is BYTE type, unlike other reference tags.

(0016,0076)

GPS Altitude​

VL Photographic Geolocation Module

0x0006

6

GPSInfo

GPSAltitude

Rational

Indicates the altitude based on the reference in GPSAltitude​Ref. Altitude is expressed as one RATIONAL value. The reference unit is meters.

(0016,0077)

GPS Time​ Stamp

VL Photographic Geolocation Module

0x0007

7

GPSInfo

GPSTime​Stamp

Rational

Indicates the time as UTC (Coordinated Universal Time). <Time​Stamp> is expressed as three RATIONAL values giving the hour, minute, and second (atomic clock).

(0016,0078)

GPS Satellites

VL Photographic Geolocation Module

0x0008

8

GPSInfo

GPSSatellites

Ascii

Indicates the GPS satellites used for measurements. This tag can be used to describe the number of satellites, their ID number, angle of elevation, azimuth, SNR and other information in ASCII notation. The format is not specified. If the GPS receiver is incapable of taking measurements, value of the tag is set to NULL.

(0016,0079)

GPS Status

VL Photographic Geolocation Module

0x0009

9

GPSInfo

GPSStatus

Ascii

Indicates the status of the GPS receiver when the image is recorded. "A" means measurement is in progress, and "V" means the measurement was interrupted.

(0016,007A)

GPS Measure ​Mode

VL Photographic Geolocation Module

0x000a

10

GPSInfo

GPSMeasure​Mode

Ascii

Indicates the GPS measurement mode. "2" means two-dimensional measurement and "3" means three-dimensional measurement is in progress.

(0016,007B)

GPS DOP

VL Photographic Geolocation Module

0x000b

11

GPSInfo

GPSDOP

Rational

Indicates the GPS DOP (data degree of precision). An HDOP value is written during two-dimensional measurement, and PDOP during three-dimensional measurement.

(0016,007C)

GPS Speed​ Ref

VL Photographic Geolocation Module

0x000c

12

GPSInfo

GPSSpeed​Ref

Ascii

Indicates the unit used to express the GPS receiver speed of movement. "K" "M" and "N" represents kilometers per hour, miles per hour, and knots.

(0016,007D)

GPS Speed​

VL Photographic Geolocation Module

0x000d

13

GPSInfo

GPSSpeed

Rational

Indicates the speed of GPS receiver movement.

(0016,007E)

GPS Track ​Ref

VL Photographic Geolocation Module

0x000e

14

GPSInfo

GPSTrack​Ref

Ascii

Indicates the reference for giving the direction of GPS receiver movement. "T" denotes true direction and "M" is magnetic direction.

(0016,007F)

GPS Track

VL Photographic Geolocation Module

0x000f

15

GPSInfo

GPSTrack

Rational

Indicates the direction of GPS receiver movement. The range of values is from 0.00 to 359.99.

(0016,0080)

GPS Img​ Direction Ref

VL Photographic Geolocation Module

0x0010

16

GPSInfo

GPSImg​DirectionRef

Ascii

Indicates the reference for giving the direction of the image when it is captured. "T" denotes true direction and "M" is magnetic direction.

(0016,0081)

GPS Img​ Direction

VL Photographic Geolocation Module

0x0011

17

GPSInfo

GPSImg​Direction

Rational

Indicates the direction of the image when it was captured. The range of values is from 0.00 to 359.99.

(0016,0082)

GPS Map​ Datum

VL Photographic Geolocation Module

0x0012

18

GPSInfo

GPSMap​Datum

Ascii

Indicates the geodetic survey data used by the GPS receiver. If the survey data is restricted to Japan, the value of this tag is "TOKYO" or "WGS-84".

(0016,0083)

GPS Dest​ Latitude Ref

VL Photographic Geolocation Module

0x0013

19

GPSInfo

GPSDest​LatitudeRef

Ascii

Indicates whether the latitude of the destination point is north or south latitude. The ASCII value "N" indicates north latitude, and "S" is south latitude.

(0016,0084)

GPS Dest​ Latitude

VL Photographic Geolocation Module

0x0014

20

GPSInfo

GPSDest​Latitude

Rational

Indicates the latitude of the destination point. The latitude is expressed as three RATIONAL values giving the degrees, minutes, and seconds, respectively. If latitude is expressed as degrees, minutes and seconds, a typical format would be dd/1,mm/1,ss/1. When degrees and minutes are used and, for example, fractions of minutes are given up to two decimal places, the format would be dd/1,mmmm/100,0/1.

(0016,0085)

GPS Dest ​Longitude Ref

VL Photographic Geolocation Module

0x0015

21

GPSInfo

GPSDest​LongitudeRef

Ascii

Indicates whether the longitude of the destination point is east or west longitude. ASCII "E" indicates east longitude, and "W" is west longitude.

(0016,0086)

GPS Dest ​Longitude

VL Photographic Geolocation Module

0x0016

22

GPSInfo

GPSDest​Longitude

Rational

Indicates the longitude of the destination point. The longitude is expressed as three RATIONAL values giving the degrees, minutes, and seconds, respectively. If longitude is expressed as degrees, minutes and seconds, a typical format would be ddd/1,mm/1,ss/1. When degrees and minutes are used and, for example, fractions of minutes are given up to two decimal places, the format would be ddd/1,mmmm/100,0/1.

(0016,0087)

GPS Dest ​Bearing Ref

VL Photographic Geolocation Module

0x0017

23

GPSInfo

GPSDest​BearingRef

Ascii

Indicates the reference used for giving the bearing to the destination point. "T" denotes true direction and "M" is magnetic direction.

(0016,0088)

GPS Dest​ Bearing

VL Photographic Geolocation Module

0x0018

24

GPSInfo

GPSDest​Bearing

Rational

Indicates the bearing to the destination point. The range of values is from 0.00 to 359.99.

(0016,0089)

GPS Dest​ Distance Ref

VL Photographic Geolocation Module

0x0019

25

GPSInfo

GPSDest​DistanceRef

Ascii

Indicates the unit used to express the distance to the destination point. "K", "M" and "N" represent kilometers, miles and knots.

(0016,008A)

GPS Dest​ Distance

VL Photographic Geolocation Module

0x001a

26

GPSInfo

GPSDest​Distance

Rational

Indicates the distance to the destination point.

(0016,008B)

GPS Processing​ Method

VL Photographic Geolocation Module

0x001b

27

GPSInfo

GPSProcessing​Method

Undefined

A character string recording the name of the method used for location finding. The first byte indicates the character code used, and this is followed by the name of the method.

(0016,008C)

GPS Area​ Information

VL Photographic Geolocation Module

0x001c

28

GPSInfo

GPSArea​Information

Undefined

A character string recording the name of the GPS area. The first byte indicates the character code used, and this is followed by the name of the GPS area.

(0016,008D)

GPS Date ​Stamp

VL Photographic Geolocation Module

0x001d

29

GPSInfo

GPSDate​Stamp

Ascii

A character string recording date and time information relative to UTC (Coordinated Universal Time). The format is "YYYY:MM:DD.".

(0016,008E)

GPS Differential

VL Photographic Geolocation Module

0x001e

30

GPSInfo

GPSDifferential

Short

Indicates whether differential correction is applied to the GPS receiver.


DICOM PS3.17 2024c - Explanatory Information