| DICOM PS3.16 2024c - Content Mapping Resource |
|---|
This template encodes a description of the anesthesia applied during a procedure (e.g., imaging of research small animals).
This template combines selected concepts from the [AQI Schema] elements, their complex types, and their children:
AnesthesiaMethodSet (type AnesthesiaMethodSetType). See http://www.aqihq.org/qcdrDataSample/prodFiles/2018%20Files/AQISchDoc/AnesthesiaMethodSet.html and http://www.aqihq.org/qcdrDataSample/prodFiles/2018%20Files/AQISchDoc/AnesthesiaMethodSetType.html.
AirwayManagementSet (type AirwayManagementSetType). See http://www.aqihq.org/qcdrDataSample/prodFiles/2018%20Files/AQISchDoc/AirwayManagementSet.html and http://www.aqihq.org/qcdrDataSample/prodFiles/2018%20Files/AQISchDoc/AirwayManagementSetType.html.
MedicationsSet (type MedicationsSetType). See http://www.aqihq.org/qcdrDataSample/prodFiles/2018%20Files/AQISchDoc/MedicationsSet.html and http://www.aqihq.org/qcdrDataSample/prodFiles/2018%20Files/AQISchDoc/MedicationsSetType.html.
Table TID 8130. Anesthesia
|
If this template is used, at least one description of anesthesia method is required. Note that the specific agents used are described separately, as intra-operative medications, per the [AQI Schema]. |
|
|
These correspond to AQI elements that are named "Time" rather than "DateTime", though their value is a DateTime; the DICOM naming convention is used here. |
|
|
Only inhalational methods of maintenance are included in this row. Absence of this row implies that the (non-inhalational) induction method is used for maintenance. |
|
|
At least one description of airway management is required. The airway management method also serves as the description of the method of inhalational anesthesia delivery, even if it does not involve "management" of the "airway" per se (e.g., delivery via nose cone). |
|
|
In the AQI model, a single AQI MedicationsSet is used in the AQI IntraOp element to describe intra-operative medications. This template allows a more general usage, with one or more Medications Set containers, each of which may be qualified by the phase of the procedure (pre-operative, intra-operative or post-operative). The purpose of the medication (e.g., general anesthetic) is described in the (111516, DCM, "Medication Type") of the included TID 8131 “Medications and Mixture Medications”. |
| DICOM PS3.16 2024c - Content Mapping Resource |
|---|