1
|
|
|
CONTAINER
|
EV (130555, DCM, "Localized Prostate Finding")
|
1
|
M
|
|
|
|
2
|
>
|
HAS OBS CONTEXT
|
TEXT
|
DT (112039, DCM, "Tracking Identifier")
|
1
|
M
|
|
|
|
3
|
>
|
HAS OBS CONTEXT
|
UIDREF
|
EV (112040, DCM, "Tracking Unique Identifier")
|
1
|
M
|
|
|
|
4
|
>
|
CONTAINS
|
CODE
|
EV (121071, DCM, "Finding")
|
1
|
M
|
|
BCID 6336 “MRI Abnormality”
|
|
5
|
>
|
HAS CONCEPT MOD
|
CODE
|
EV (363698007, SCT, "Finding site")
|
1-n
|
M
|
|
BCID 6300 “Prostate Anatomy”
|
|
6
|
>>
|
HAS CONCEPT MOD
|
CODE
|
EV (272741003, SCT, "Laterality")
|
1
|
U
|
|
DCID 244 “Laterality”
|
|
7
|
>>
|
HAS CONCEPT MOD
|
CODE
|
EV (106233006, SCT, "Topographical modifier")
|
1
|
U
|
|
|
|
8
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3909 “Best Illustration of Findings”
|
1-n
|
U
|
|
|
|
9
|
>
|
CONTAINS
|
INCLUDE
|
DTID 1410 “Planar ROI Measurements and Qualitative Evaluations”
|
1-n
|
MC
|
IF Rows 10, 11 are absent
|
$Measurement = BCID 218 “Quantitative Image Feature”
$Units = BCID 7181 “Abstract Multi-dimensional Image Model Component Unit”
$Derivation = BCID 7464 “General Region of Interest Measurement Modifier”
$Method = BCID 6147 “Response Criteria”
$FindingType = Value of Row 4
$TargetSite = Value of Row 5
$TrackingID = Value of Row 2
$TrackingUID = Value of Row 3
$QualType = BCID 6333 “mpMRI Assessment Type”
$QualValue = BCID 6335 “mpMRI Assessment Value”
|
|
10
|
>
|
CONTAINS
|
INCLUDE
|
DTID 1411 “Volumetric ROI Measurements and Qualitative Evaluations”
|
1-n
|
MC
|
IF Rows 9, 11 are absent
|
$Measurement = BCID 218 “Quantitative Image Feature”
$Units = BCID 7181 “Abstract Multi-dimensional Image Model Component Unit”
$Derivation = BCID 7464 “General Region of Interest Measurement Modifier”
$Method = BCID 6147 “Response Criteria”
$FindingType = Value of Row 4
$TargetSite = Value of Row 5
$TrackingID = Value of Row 2
$TrackingUID = Value of Row 3
$QualType = BCID 6333 “mpMRI Assessment Type”
$QualValue = BCID 6335 “mpMRI Assessment Value”
|
|
11
|
>
|
CONTAINS
|
INCLUDE
|
DTID 1501 “Measurement and Qualitative Evaluation Group”
|
1-n
|
MC
|
IF Rows 9, 10 are absent
|
$Measurement = BCID 218 “Quantitative Image Feature”
$Units = BCID 7181 “Abstract Multi-dimensional Image Model Component Unit”
$Derivation = BCID 7464 “General Region of Interest Measurement Modifier”
$Method = BCID 6147 “Response Criteria”
$FindingType = Value of Row 4
$TargetSite = Value of Row 5
$TrackingID = Value of Row 2
$TrackingUID = Value of Row 3
$QualType = BCID 6333 “mpMRI Assessment Type”
$QualValue = BCID 6335 “mpMRI Assessment Value”
$ImagePurpose = EV (260753009, SCT, "Source")
|
|
12
|
>
|
CONTAINS
|
CONTAINER
|
EV (C0034375, UMLS, "Qualitative Evaluations")
|
1
|
MC
|
IF Row 6 and 10 are absent
|
|
|
13
|
>>
|
CONTAINS
|
CODE
|
DCID 6333 “mpMRI Assessment Type”
|
1-n
|
U
|
|
BCID 6335 “mpMRI Assessment Value”
|
|
14
|
>>
|
CONTAINS
|
TEXT
|
DCID 6333 “mpMRI Assessment Type”
|
1-n
|
U
|
|
|
|
15
|
>
|
CONTAINS
|
CONTAINER
|
EV (130556, DCM, "Prostate relational measurements")
|
1
|
M
|
|
|
|
16
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 300 “Measurement”
|
1-n
|
U
|
|
$Measurement = BCID 6351 “Prostate Relational Measurement”
|
|
17
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 4306 “PI-RADS® Localized Abnormality Assessment”
|
1
|
U
|
|
|