DICOM PS3.16 2024c - Content Mapping Resource

TID 4106 Response Evaluation

This Template provides a means to report response evaluation to cancer treatment, based on a method such as RECIST or WHO.

Type:

Non-Extensible

Order:

Significant

Root:

No

Table TID 4106. Response Evaluation

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (112020, DCM, "Response Evaluation")

1

M

2

>

HAS OBS CONTEXT

CODE

EV (112021, DCM, "Response Evaluation Method")

1

M

DT (112022, DCM, "RECIST") or

DT (112029, DCM, "WHO")

3

>

CONTAINS

CODE

EV (112048, DCM, "Current Response")

1

U

DCID 6143 “Lesion Response”

4

>

CONTAINS

CODE

EV (112049, DCM, "Best Overall Response")

1

U

DCID 6143 “Lesion Response”

5

>

CONTAINS

NUM

EV (112051, DCM, "Measurement of Response")

1

U

UNITS not specified


DICOM PS3.16 2024c - Content Mapping Resource