| DICOM PS3.16 2024c - Content Mapping Resource |
|---|
This Template describes a single image finding for a lesion or other object. The details of the finding are expressed in this Template and/or more specific Templates. The details from which a single image Calcification Cluster is inferred may be expressed in a number of Single Image Findings (see TID 4006 “Mammography CAD Single Image Finding”) of type Individual Calcification.
A Single Image Finding of type Breast Composition may be INFERRED FROM by-reference to a Single Image Finding of type Breast Geometry.
Table TID 4006. Mammography CAD Single Image Finding
|
IFF value of Row 2 = (111151, DCM, "Presentation Optional") and Row 9 of TID 4017 “CAD Detection Performed” is present |
UNITS = DT ({1:n}, UCUM, "range: 1:n"), where n is the maximum specified in Row 9 of TID 4017 “CAD Detection Performed”. Value is restricted to being an integer |
|||||||
|
May be present unless value of parent is (129715009, SCT, "Breast composition"), (111100, DCM, "Breast geometry"), (24142002, SCT, "Nipple"), (111099, DCM, "Selected region"), (111101, DCM, "Image quality") or (111102, DCM, "Non-lesion") |
||||||||
|
Shall be present unless value of parent is (129715009, SCT, "Breast composition"), (111100, DCM, "Breast geometry") or (111101, DCM, "Image quality") |
||||||||
|
Shall be present only if value of parent is (129715009, SCT, "Breast composition") |
||||||||
|
May be present only if value of parent is (129715009, SCT, "Breast composition") |
Shall reference a (111059, DCM, "Single Image Finding") of value: EV (111100, DCM, "Breast geometry") |
|||||||
|
Shall be present only if value of parent is (111100, DCM, "Breast geometry") |
||||||||
|
May be present only if value of parent is (129770007, SCT, "Individual Calcification") |
||||||||
|
May be present only if value of parent is (129769006, SCT, "Calcification Cluster") |
||||||||
|
May be present only if value of parent is (129793001, SCT, "Mammography breast density") |
||||||||
|
May be present only if value of parent is (24142002, SCT, "Nipple") |
||||||||
|
Shall be present only if value of parent is (111102, DCM, "Non-lesion") |
||||||||
|
Shall be present only if value of parent is (111099, DCM, "Selected Region") |
||||||||
|
IF value of parent is (111101, DCM, "Image quality") and IFF Row 19 is not present |
Shall reference an IMAGE Content Item in the (111028, DCM, "Image Library") |
|||||||
|
IF value of parent is (111101, DCM, "Image quality") and IFF Row 18 is not present |
||||||||
|
All the (111030, DCM, "Image Region") Content Items in a single invocation of this Template shall reference the same IMAGE Content Item in the (111028, DCM, "Image Library") |
||||||||
|
Shall be present only if value of parent is (111101, DCM, "Image quality") |
$QualityFinding = DCID 6041 “Mammography Image Quality Finding” $QualityStandard = DCID 6045 “Mammography Quality Control Standard Type” |
|||||||
|
May be present only if value of parent is (129769006, SCT, "Calcification Cluster") |
||||||||
|
Shall be present only if this finding is incorporated from a different report than its parent. |
|
This Content Item constrains the SCP receiving the Mammography CAD SR IOD in its use of the contents of this Template and its Target Content Items. Mammography CAD devices may opt to use data marked "Not for Presentation" or "Presentation Optional" as input to subsequent mammography CAD processing steps. Refer to Section O.2 “Structured Reporting Storage SOP Class SCU and SCP Behavior” in PS3.4 . |
|
|
Additional information to use when Rendering Intent is "Presentation Optional". A CAD Operating Point of zero is not sent, and is encoded as a Rendering Intent of "Presentation Required". See Section O.2 “Structured Reporting Storage SOP Class SCU and SCP Behavior” in PS3.4 and Section E.4 “CAD Operating Point” in PS3.17 . |
|
|
The likelihood that the finding detected, and classified by the CODE specified in the Single Image Finding parent Template, is in fact that type of finding. |
|
|
A Single Image Finding (whose parent is a Single Image Finding of type Calcification Cluster) allows one level of nesting for the definition of individual calcifications within the cluster. To use this Template recursively, this Single Image Finding Code Value shall be "Individual Calcification". |
| DICOM PS3.16 2024c - Content Mapping Resource |
|---|