DICOM PS3.16 2024c - Content Mapping Resource

TID 3914 Arterial Dissection Properties

Properties of a arterial dissection finding

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3914. Arterial Dissection Properties

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

HAS PROPERTIES

CODE

EV (122387, DCM, "Dissection Classification")

1

M

DCID 3492 “Vascular Dissection Classification”

2

HAS PROPERTIES

CODE

EV (134198009, SCT, "Etiology")

1

U

DCID 3809 “Associated Condition”

3

HAS PROPERTIES

NUM

EV (410668003, SCT, "Length")

1

U

UNITS = DT (mm, UCUM, "mm")

4

HAS PROPERTIES

CODE

EV (413530006, SCT, "Anatomic structure potentially involved in evolution of disease")

1-n

U

DCID 3827 “Vessel Segment”


DICOM PS3.16 2024c - Content Mapping Resource