DICOM PS3.16 2024c - Content Mapping Resource

TID 3907 Vessel Measurements

Contains measurements made on vessel level.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3907. Vessel Measurements

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

NUM

EV (408715008, SCT, "Lumen Diameter Stenosis")

1

U

UNITS = DT (%, UCUM, "%")

2

CONTAINS

NUM

EV (408714007, SCT, "Lumen Area Stenosis")

1

U

UNITS = DT (%, UCUM, "%")

3

CONTAINS

NUM

EV (121206, DCM, "Distance")

1-n

U

UNITS = DT (mm, UCUM, "mm")

4

>

HAS CONCEPT MOD

CODE

EV (122340, DCM, "Fiducial Feature")

2

M

5

>>

HAS CONCEPT MOD

CODE

EV (272741003, SCT, "Laterality")

1

U

DCID 244 “Laterality”

6

>

INCLUDE

DTID 320 “Image or Spatial Coordinates”

1

U

7

CONTAINS

NUM

EV (397413000, SCT, "Vessel Lumen Diameter")

1-n

U

UNITS = DT (mm, UCUM, "mm")

8

>

HAS CONCEPT MOD

CODE

EV (121401, DCM, "Derivation")

1

U

DCID 3488 “Min/Max/Mean”

9

>

HAS PROPERTIES

NUM

EV (122337, DCM, "Relative Position")

1

U

UNITS = EV (mm, UCUM, "mm")

10

>>

HAS CONCEPT MOD

CODE

EV (122340, DCM, "Fiducial Feature")

1

M

DCID 3837 “Fiducial Feature”

11

CONTAINS

NUM

EV (130408, DCM, "Perivascular adipose tissue fat attenuation index")

1

U

UNITS = EV (1, UCUM, "no units")


Content Item Descriptions

Rows 3-5

The distance between two identified fiducial features

Rows 7-10

Measurement of vessel diameter made at a position relative to a fiducial feature

Row 9

A positive value indicates a distance in the direction of flow within the vessel

DICOM PS3.16 2024c - Content Mapping Resource