|
1
|
|
|
CONTAINER
|
EV (59776-5, LN, "Findings")
|
1
|
M
|
|
|
|
2
|
>
|
HAS CONCEPT MOD
|
CODE
|
EV (111004, DCM, "Analysis Performed")
|
1
|
M
|
|
$AnalysisPerformed
|
|
3
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3905 “Calcium Scoring Results”
|
1
|
UC
|
IFF the value of Row 2 is EV (122605, DCM, "Vascular Morphological Analysis")
|
|
|
4
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (281231009, SCT, "Blood Vessel of Head")
$SectionLaterality = EV (7771000, SCT, "Left")
$Anatomy = DCID 12105 “Intracranial Cerebral Vessel”
$AnalysisPerformed = $AnalysisPerformed
|
|
5
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (281231009, SCT, "Blood Vessel of Head")
$SectionLaterality = EV (24028007, SCT, "Right")
$Anatomy = DCID 12105 “Intracranial Cerebral Vessel”
$AnalysisPerformed = $AnalysisPerformed
|
|
6
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (281231009, SCT, "Blood Vessel of Head")
$SectionLaterality = EV (66459002, SCT, "Unilateral")
$Anatomy = DCID 12106 “Intracranial Cerebral Vessel (Unilateral)”
$AnalysisPerformed = $AnalysisPerformed
|
|
7
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (119568004, SCT, "Artery of Neck")
$SectionLaterality = EV (7771000, SCT, "Left")
$Anatomy = DCID 12104 “Extracranial Artery”
$AnalysisPerformed = $AnalysisPerformed
|
|
8
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (119568004, SCT, "Artery of Neck")
$SectionLaterality = EV (24028007, SCT, "Right")
$Anatomy = DCID 12104 “Extracranial Artery”
$AnalysisPerformed = $AnalysisPerformed
|
|
9
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (70791007, SCT, "Artery of Lower Extremity")
$SectionLaterality = EV (7771000, SCT, "Left")
$Anatomy = DCID 12109 “Lower Extremity Artery”
$AnalysisPerformed = $AnalysisPerformed
|
|
10
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (70791007, SCT, "Artery of Lower Extremity")
$SectionLaterality = EV (24028007, SCT, "Right")
$Anatomy = DCID 12109 “Lower Extremity Artery”
$AnalysisPerformed = $AnalysisPerformed
|
|
11
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (122774002, SCT, "Vein of Lower Extremity")
$SectionLaterality = EV (7771000, SCT, "Left")
$Anatomy = DCID 12110 “Lower Extremity Vein”
$AnalysisPerformed = $AnalysisPerformed
|
|
12
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (122774002, SCT, "Vein of Lower Extremity")
$SectionLaterality = EV (24028007, SCT, "Right")
$Anatomy = DCID 12110 “Lower Extremity Vein”
$AnalysisPerformed = $AnalysisPerformed
|
|
13
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (75531005, SCT, "Artery of Upper Extremity")
$SectionLaterality = EV (7771000, SCT, "Left")
$Anatomy = DCID 12107 “Upper Extremity Artery”
$AnalysisPerformed = $AnalysisPerformed
|
|
14
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (75531005, SCT, "Artery of Upper Extremity")
$SectionLaterality = EV (24028007, SCT, "Right")
$Anatomy = DCID 12107 “Upper Extremity Artery”
$AnalysisPerformed = $AnalysisPerformed
|
|
15
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (122775001, SCT, "Vein of Upper Extremity")
$SectionLaterality = EV (7771000, SCT, "Left")
$Anatomy = DCID 12108 “Upper Extremity Vein”
$AnalysisPerformed = $AnalysisPerformed
|
|
16
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (122775001, SCT, "Vein of Upper Extremity")
$SectionLaterality = EV (24028007, SCT, "Right")
$Anatomy = DCID 12108 “Upper Extremity Vein”
$AnalysisPerformed = $AnalysisPerformed
|
|
17
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (303402001, SCT, "Vascular Structure of Kidney")
$SectionLaterality = EV (7771000, SCT, "Left")
$Anatomy = DCID 12115 “Renal Vessel”
$AnalysisPerformed = $AnalysisPerformed
|
|
18
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (303402001, SCT, "Vascular Structure of Kidney")
$SectionLaterality = EV (24028007, SCT, "Right")
$Anatomy = DCID 12115 “Renal Vessel”
$AnalysisPerformed = $AnalysisPerformed
|
|
19
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (118634008, SCT, "Artery of Abdomen")
$SectionLaterality = EV (7771000, SCT, "Left")
$Anatomy = DCID 12111 “Abdominopelvic Artery (Paired)”
$AnalysisPerformed = $AnalysisPerformed
|
|
20
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (118634008, SCT, "Artery of Abdomen")
$SectionLaterality = EV (24028007, SCT, "Right")
$Anatomy = DCID 12111 “Abdominopelvic Artery (Paired)”
$AnalysisPerformed = $AnalysisPerformed
|
|
21
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (118634008, SCT, "Artery of Abdomen")
$SectionLaterality = EV (66459002, SCT, "Unilateral")
$Anatomy = DCID 12112 “Abdominopelvic Artery (Unpaired)”
$AnalysisPerformed = $AnalysisPerformed
|
|
22
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (84421000, SCT, "Vein of Abdomen")
$SectionLaterality = EV (7771000, SCT, "Left")
$Anatomy = DCID 12113 “Abdominopelvic Vein (Paired)”
$AnalysisPerformed = $AnalysisPerformed
|
|
23
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (84421000, SCT, "Vein of Abdomen")
$SectionLaterality = EV (24028007, SCT, "Right")
$Anatomy = DCID 12113 “Abdominopelvic Vein (Paired)”
$AnalysisPerformed = $AnalysisPerformed
|
|
24
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (84421000, SCT, "Vein of Abdomen")
$SectionLaterality = EV (66459002, SCT, "Unilateral")
$Anatomy = DCID 12114 “Abdominopelvic Vein (Unpaired)”
$AnalysisPerformed = $AnalysisPerformed
|
|
25
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (81040000, SCT, "Pulmonary Artery Structure")
$SectionLaterality = EV (66459002, SCT, "Unilateral")
$Anatomy = DCID 3829 “Pulmonary Artery”
$AnalysisPerformed = $AnalysisPerformed
|
|
26
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (41801008, SCT, "Coronary Artery Structure")
$Anatomy = DCID 3015 “Coronary Artery”
$AnalysisPerformed = $AnalysisPerformed
|
|
27
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (85439003, SCT, "Cardiac Vein Structure")
$Anatomy = DCID 3839 “Coronary Vein”
$AnalysisPerformed = $AnalysisPerformed
|
|
28
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3906 “Vascular Section Measurements”
|
1-n
|
U
|
|
$VascularSection = DT (122972007, SCT, "Pulmonary Venous Structure")
$Anatomy = DCID 3840 “Pulmonary Vein”
$AnalysisPerformed = $AnalysisPerformed
|