|
1
|
|
|
CONTAINER
|
EV (55111-9, LN, "Current Procedure Descriptions")
|
1
|
M
|
|
|
|
2
|
>
|
HAS CONCEPT MOD
|
CODE
|
EV (121058, DCM, "Procedure reported")
|
1
|
M
|
|
DT (122061, DCM, "Percutaneous Coronary Intervention")
|
|
3
|
>
|
CONTAINS
|
PNAME
|
EV (121114, DCM, "Performing Physician")
|
1
|
M
|
|
|
|
4
|
>
|
CONTAINS
|
PNAME
|
EV (121088, DCM, "Fellow")
|
1-n
|
U
|
|
|
|
5
|
>
|
CONTAINS
|
PNAME
|
DCID 7452 “Organizational Role”
|
1-n
|
U
|
|
|
|
6
|
>
|
CONTAINS
|
CODE
|
EV (260870009, SCT, "Procedure Priority")
|
1
|
M
|
|
DCID 3414 “Procedure Urgency”
|
|
7
|
>
|
CONTAINS
|
CONTAINER
|
EV (18785-6, LN, "Indications for Procedure")
|
1
|
U
|
|
|
|
8
|
>>
|
CONTAINS
|
CODE
|
EV (121071, DCM, "Finding")
|
1-n
|
U
|
|
DCID 3726 “Coronary Intervention Indication”
|
|
9
|
>>
|
CONTAINS
|
CODE
|
EV (122172, DCM, "Acute MI Present")
|
1
|
U
|
|
DCID 230 “Yes-No”
|
|
10
|
>>>
|
HAS PROPERTIES
|
CODE
|
DT (122170, DCM, "Type of Myocardial Infarction")
|
1
|
U
|
|
DCID 3723 “MI Type”
|
|
11
|
>>>
|
HAS PROPERTIES
|
DATETIME
|
EV (122173, DCM, "ST Elevation Onset DateTime")
|
1
|
U
|
|
|
|
12
|
>>
|
CONTAINS
|
TEXT
|
EV (121071, DCM, "Finding")
|
1-n
|
U
|
|
|
|
13
|
>
|
CONTAINS
|
NUM
|
EV (122175, DCM, "Number of lesion interventions attempted")
|
1
|
M
|
|
UNITS = EV (1, UCUM, "units")
|
|
14
|
>
|
CONTAINS
|
NUM
|
EV (122176, DCM, "Number of lesion interventions successful")
|
1
|
M
|
|
UNITS = EV (1, UCUM, "units")
|
|
15
|
>
|
CONTAINS
|
CODE
|
EV (122177, DCM, "Procedure Result")
|
1
|
M
|
|
DCID 3749 “PCI Procedure Result”
|
|
16
|
>
|
CONTAINS
|
TEXT
|
EV (122177, DCM, "Procedure Result")
|
1
|
U
|
|
|
|
17
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3808 “Lesion Intervention Information”
|
1-n
|
M
|
|
|