1
|
|
|
CONTAINER
|
DT (18752-6, LN, "Stress Testing Report")
|
1
|
M
|
|
Root node
|
|
2
|
>
|
HAS CONCEPT MOD
|
CODE
|
EV (121058, DCM, "Procedure reported")
|
1
|
M
|
|
BCID 3200 “Stress Test Procedure”
|
|
3
|
>
|
HAS CONCEPT MOD
|
INCLUDE
|
DTID 1204 “Language of Content Item and Descendants”
|
1
|
M
|
|
|
|
4
|
>
|
HAS OBS CONTEXT
|
INCLUDE
|
DTID 1002 “Observer Context”
|
1-n
|
M
|
|
|
|
5
|
>
|
CONTAINS
|
CONTAINER
|
EV (18785-6, LN, "Indications for Procedure")
|
1
|
U
|
|
|
|
6
|
>>
|
CONTAINS
|
CODE
|
EV (121071, DCM, "Finding")
|
1-n
|
U
|
|
DCID 3201 “Indications for Stress Test”
|
|
7
|
>>
|
CONTAINS
|
TEXT
|
EV (121071, DCM, "Finding")
|
1
|
U
|
|
|
|
8
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3602 “Cardiovascular Patient Characteristics”
|
1
|
M
|
|
|
|
9
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3802 “Cardiovascular Patient History”
|
1
|
U
|
|
|
|
10
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3301 “Stress Test Procedure Description”
|
1
|
M
|
|
|
|
11
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3303 “Stress Test Phase Data”
|
1-n
|
M
|
|
|
|
12
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3311 “Stress Test Summary”
|
1
|
U
|
|
|
|
13
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3318 “Comparison to Prior Stress Study”
|
1
|
U
|
|
|
|
14
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3320 “Conclusions and Recommendations”
|
1
|
U
|
|
|