|
DCM
|
126752
|
28H1 ^89^Zr
|
|
|
|
|
DCM
|
126713
|
2FA F^18^
|
|
|
FA-85380
|
|
DCM
|
126751
|
7D12 ^89^Zr
|
|
|
|
|
DCM
|
126750
|
7E11 ^89^Zr
|
|
|
|
|
SCT
|
129513004
|
Acetate C^11^
|
C-B1043
|
C1098488
|
|
|
DCM
|
126729
|
AGN-150998 ^89^Zr
|
|
|
MP0112
|
|
SCT
|
129508003
|
Ammonia N^13^
|
C-B103C
|
C1268560
|
|
|
DCM
|
126754
|
Anti-B220 ^89^Zr
|
|
|
Anti-CD45R
|
|
DCM
|
126700
|
ATSM Cu^60^
|
|
|
|
|
DCM
|
126701
|
ATSM Cu^61^
|
|
|
|
|
DCM
|
126702
|
ATSM Cu^62^
|
|
|
|
|
SCT
|
422855001
|
ATSM Cu^64^
|
C-B07DB
|
C1828021
|
|
|
DCM
|
126722
|
Benralizumab ^89^Zr
|
|
|
MEDI-563, KHK4563
|
|
DCM
|
126516
|
Bevacizumab ^89^Zr
|
|
|
Avastin™ ^89^Zr
|
|
DCM
|
126727
|
Blinatumomab ^89^Zr
|
|
|
AMG103, MT103
|
|
DCM
|
126735
|
Brentuximab ^89^Zr
|
|
|
Adcetris™
|
|
SCT
|
422540000
|
Butanol O^15^
|
C-B07DC
|
C1827030
|
|
|
SCT
|
129507008
|
Carbon dioxide O^15^
|
C-B103B
|
C1268559
|
|
|
SCT
|
129515006
|
Carbon monoxide C^11^
|
C-B1045
|
C1268564
|
|
|
SCT
|
129506004
|
Carbon monoxide O^15^
|
C-B103A
|
C1268558
|
|
|
SCT
|
129511002
|
Carfentanil C^11^
|
C-B103F
|
C1268562
|
|
|
DCM
|
126513
|
Cetuximab ^89^Zr
|
|
|
Erbitux™ ^89^Zr
|
|
DCM
|
126517
|
cG250-F(ab')(2) ^89^Zr
|
|
|
|
|
DCM
|
126703
|
Choline C^11^
|
|
|
|
|
DCM
|
126715
|
CLR1404 I^124^
|
|
|
|
|
DCM
|
126716
|
CLR1404 I^131^
|
|
|
|
|
DCM
|
126746
|
cMAb U36 ^89^Zr
|
|
|
|
|
DCM
|
126515
|
cU36 ^89^Zr
|
|
|
|
|
NCIt
|
C96234
|
DCFBC F^18^
|
|
C2604127
|
N-[N-[(S)-1,3-dicarboxypropyl]carbamoyl]-4-fluorobenzyl-l-cysteine F^18^
|
|
NCIt
|
C116352
|
Piflufolastat F^18^
|
|
C3492634
|
2-(3-(1-carboxy-5-[(6-fluoro-pyridine-3-carbonyl)-amino]-pentyl)-ureido)-pentanedioic acid F^18^, DCFPyL F^18^, Pylarify™, Pylclari™
|
|
DCM
|
126762
|
Df-[FK](2) ^89^Zr
|
|
|
|
|
DCM
|
126763
|
Df-[FK](2)-3PEG(4) ^89^Zr
|
|
|
|
|
DCM
|
126520
|
Df-CD45 ^89^Zr
|
|
|
|
|
DCM
|
126760
|
Df-FK ^89^Zr
|
|
|
|
|
DCM
|
126761
|
Df-FK-PEG(3) ^89^Zr
|
|
|
|
|
DCM
|
126747
|
DN30 ^89^Zr
|
|
|
|
|
DCM
|
126765
|
DPA-713 ^11^C
|
|
|
|
|
DCM
|
126766
|
DPA-714 ^18^F
|
|
|
|
|
DCM
|
126519
|
E4G10 ^89^Zr
|
|
|
|
|
DCM
|
126732
|
Ecromeximab ^89^Zr
|
|
|
KW-2871
|
|
UMLS
|
C2713594
|
Edotreotide Ga^68^
|
|
C2713594
|
DOTATOC, SMT487
|
|
SCT
|
423498000
|
EDTA Ga^68^
|
C-B07DD
|
C1828067
|
|
|
DCM
|
126704
|
Fallypride C^11^
|
|
|
|
|
DCM
|
126705
|
Fallypride F^18^
|
|
|
|
|
DCM
|
126706
|
FLB 457 C^11^
|
|
|
|
|
SCT
|
712736002
|
Florbetaben F^18^
|
C-D6858
|
C3818757
|
NeuroCeq™
|
|
SCT
|
456995000
|
Florbetapir F^18^
|
C-E0269
|
C3475363
|
AV-45, Amyvid™
|
|
SCT
|
879808000
|
Flortaucipir F^18^
|
|
C4742689
|
AV-1451, T807, Tauvid
|
|
DCM
|
126503
|
Flubatine F^18^
|
|
|
NCFHEB
|
|
SCT
|
456999006
|
Fluciclatide F^18^
|
C-E0265
|
C2987729
|
|
|
SCT
|
457000009
|
Fluciclovine F^18^
|
C-E026A
|
C1311253
|
|
|
SCT
|
423543007
|
Flumazenil C^11^
|
C-B07DE
|
C1827653
|
|
|
SCT
|
422975006
|
Flumazenil F^18^
|
C-B07DF
|
C1828330
|
|
|
SCT
|
424708001
|
Fluorethyltyrosin F^18^
|
C-B07E0
|
C1827913
|
|
|
SCT
|
423546004
|
Fluorobenzothiazole F^18^
|
C-B07E4
|
C1827131
|
|
|
SCT
|
456992002
|
Fluorocholine F^18^
|
C-E0273
|
C3531803
|
|
|
SCT
|
35321007
|
Fluorodeoxyglucose F^18^
|
C-B1031
|
C0046056
|
|
|
SCT
|
926372005
|
Fluoroestradiol F^18^
|
|
C1831937
|
FES
|
|
UMLS
|
C1541539
|
Fluoroetanidazole F^18^
|
|
C1541539
|
EF5
|
|
SCT
|
5811000122108
|
Fluoro-L-dopa F^18^
|
C-E0241
|
C0244672
|
|
|
SCT
|
422763008
|
Fluoromethane F^18^
|
C-B07E2
|
C1827137
|
|
|
SCT
|
422598008
|
Fluoromisonidazole F^18^
|
C-B07E1
|
C1827349
|
FMISO
|
|
UMLS
|
C2934038
|
Fluoropropyl-dihydrotetrabenazine F^18^
|
|
C2934038
|
AV-133, DTBZ
|
|
DCM
|
126707
|
Fluorotriopride F^18^
|
|
|
|
|
SCT
|
425236000
|
Fluorouracil F^18^
|
C-B07E3
|
C1827690
|
|
|
DCM
|
126718
|
Flurpiridaz F^18^
|
|
|
BMS-747158-02
|
|
SCT
|
456997008
|
Flutemetamol F^18^
|
C-E0267
|
C2983948
|
Vizamyl™
|
|
DCM
|
126748
|
Fresolimumab ^89^Zr
|
|
|
GC1008
|
|
DCM
|
126731
|
GA201 ^89^Zr
|
|
|
RG1760, RO5083945
|
|
SCT
|
53315004
|
Germanium Ge^68^
|
C-128A2
|
C0303198
|
|
|
DCM
|
126724
|
Glembatumumab vedotin ^89^Zr
|
|
|
CDX-011, CR011-vcMMAE
|
|
SCT
|
129509006
|
Glutamate N^13^
|
C-B103D
|
C1268561
|
|
|
DCM
|
126709
|
Glutamine C^11^
|
|
|
|
|
DCM
|
126710
|
Glutamine C^14^
|
|
|
|
|
DCM
|
126711
|
Glutamine F^18^
|
|
|
|
|
UMLS
|
C2981788
|
ISO-1 F^18^
|
|
C2981788
|
|
|
DCM
|
126514
|
J591 ^89^Zr
|
|
|
|
|
DCM
|
126740
|
Margetuximab ^89^Zr
|
|
|
MGAH22
|
|
DCM
|
126730
|
MEDI-551 ^89^Zr
|
|
|
|
|
SCT
|
424789007
|
Mespiperone C^11^
|
C-B07E5
|
C1828032
|
|
|
SCT
|
129510001
|
Methionine C^11^
|
C-B103E
|
C0252667
|
|
|
UMLS
|
C4506764
|
MK-6240 F^18^
|
|
C4506764
|
|
|
DCM
|
126738
|
Mogamulizumab ^89^Zr
|
|
|
AMG761, KW-0761, Poteligeo™
|
|
DCM
|
126510
|
Monoclonal Antibody ^64^Cu
|
|
|
|
|
DCM
|
126511
|
Monoclonal Antibody ^89^Zr
|
|
|
|
|
SCT
|
423249007
|
Monoclonal antibody I^124^
|
C-114AA
|
C1827605
|
|
|
DCM
|
126753
|
Nanocolloidal albumin ^89^Zr
|
|
|
Nanocoll
|
|
DCM
|
126714
|
Nifene F^18^
|
|
|
|
|
DCM
|
126721
|
Obinituzimab ^89^Zr
|
|
|
Afutuzumab, Gazyva™
|
|
DCM
|
126723
|
Ocaratuzumab ^89^Zr
|
|
|
AME-133v, LY2469298
|
|
SCT
|
129504001
|
Oxygen O^15^
|
C-B1038
|
C1268556
|
|
|
SCT
|
129505000
|
Oxygen-water O^15^
|
C-B1039
|
C1268557
|
|
|
SCT
|
129514005
|
Palmitate C^11^
|
C-B1044
|
C1268563
|
|
|
DCM
|
126736
|
Panitumumab ^89^Zr
|
|
|
ABX-EGF, Vectibix™
|
|
DCM
|
126728
|
Pegdinetanib ^89^Zr
|
|
|
BMS-844203, CT-322, Angiocept™
|
|
DCM
|
126725
|
Pinatuzumab vedotin ^89^Zr
|
|
|
RG7593, DCDT2980S
|
|
DCM
|
126500
|
Pittsburgh compound B C^11^
|
|
|
PIB
|
|
UMLS
|
C1609883
|
PK11195 ^11^C
|
|
C1609883
|
(11C)1-(2-chlorophenyl)-N-methyl-N-(1-methylpropyl)-3-isoquinolinecarboxamide
|
|
DCM
|
126726
|
Polatuzumab vedotin ^89^Zr
|
|
|
RG7596, DCDS4501A
|
|
DCM
|
126758
|
PSMA-1007 F^18^
|
|
|
|
|
NCIt
|
C118961
|
PSMA-11 Ga^68^
|
|
C3899042
|
Glu‑NH‑CO‑NH‑Lys(Ahx)-HBED‑CC Ga^68^
|
|
DCM
|
126759
|
PSMA-617 Ga^68^
|
|
|
|
|
SCT
|
422789008
|
PTSM Cu^62^
|
C-B07E7
|
C1827357
|
|
|
DCM
|
126518
|
R1507 ^89^Zr
|
|
|
|
|
SCT
|
129512009
|
Raclopride C^11^
|
C-B1042
|
C0752264
|
|
|
DCM
|
126742
|
Ranibizumab ^89^Zr
|
|
|
Lucentis™
|
|
DCM
|
126737
|
Rituximab ^89^Zr
|
|
|
IDEC-C2B8, Rituxan™
|
|
DCM
|
126755
|
RO5323441 ^89^Zr
|
|
|
|
|
DCM
|
126756
|
RO542908 ^89^Zr
|
|
|
|
|
DCM
|
126719
|
RO6924963 ^11^C
|
|
|
RO-963
|
|
DCM
|
126720
|
RO6931643 ^11^C
|
|
|
RO-643
|
|
DCM
|
126757
|
RO6958948 ^18^F
|
|
|
RO-948
|
|
DCM
|
126733
|
Roledumab ^89^Zr
|
|
|
LFB-R593
|
|
SCT
|
129503007
|
Rubidium chloride Rb^82^
|
C-B1037
|
C1268555
|
|
|
DCM
|
126741
|
SAR3419 ^89^Zr
|
|
|
|
|
NCIt
|
C122684
|
Sarcosine C^11^
|
|
C4055275
|
|
|
SCT
|
129501009
|
Sodium fluoride F^18^
|
C-B1032
|
C0304965
|
|
|
SCT
|
422980002
|
Sodium iodide I^124^
|
C-B07E8
|
C1828393
|
|
|
SCT
|
71633006
|
Sodium Na^22^
|
C-155A1
|
C1268566
|
|
|
SCT
|
129499001
|
Spiperone F^18^
|
C-B1033
|
C1268552
|
|
|
DCM
|
126502
|
T807 F^18^
|
|
|
AV-1451
|
|
UMLS
|
C4550127
|
THK5317 F^18^
|
|
C4550127
|
|
|
UMLS
|
C4279748
|
THK5351 F^18^
|
|
C4279748
|
|
|
SCT
|
129502002
|
Thymidine F^18^
|
C-B1036
|
C1268554
|
FLT
|
|
DCM
|
126512
|
Trastuzumab ^89^Zr
|
|
|
Herceptin™ ^89^Zr
|
|
DCM
|
126749
|
TRC105 ^89^Zr
|
|
|
|
|
SCT
|
724025002
|
Dotatate Ga^68^
|
|
C1742831
|
|
|
DCM
|
126739
|
Ublituximab ^89^Zr
|
|
|
LFB-R603, TG-1101
|
|
UMLS
|
C4506788
|
UCB-J C^11^
|
|
C4506788
|
|
|
DCM
|
126734
|
XmAb5574 ^89^Zr
|
|
|
MOR208
|