DICOM PS3.16 2024c - Content Mapping Resource

CID 3415 Cardiac Rhythm

This Context Group comprises the ECG rhythm annotations of ISO/IEEE 11073-10102. The terms included in the table below may not constitute the complete list; see the ISO/IEEE Standard.

Note

Codes reprinted by permission of IEEE, Copyright 2004 by IEEE. ISO/IEEE 11073-10102 available through http://standards.ieee.org/.

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

CardiacRhythm

FHIR Keyword:

dicom-cid-3415-CardiacRhythm

Type:

Extensible

Version:

20080927

UID:

1.2.840.10008.6.1.80

Table CID 3415. Cardiac Rhythm

Coding Scheme Designator

Code Value

Code Meaning

ISO/IEEE 11073 MDC Equivalent Reference ID (Informative)

MDC

10:9216

Sinus Rhythm

MDC_ECG_RHY_SINUS_RHY

MDC

10:9232

Normal Sinus Rhythm

MDC_ECG_RHY_SINUS_NORMAL_RHY

MDC

10:9248

Sinus Bradycardia

MDC_ECG_RHY_SINUS_BRADY

MDC

10:9264

Sinus Tachycardia

MDC_ECG_RHY_SINUS_TACHY

MDC

10:9280

Sinus Arrhythmia

MDC_ECG_RHY_SINUS_ARRHY

MDC

10:9296

Respiratory Sinus Arrhythmia

MDC_ECG_RHY_RESP_ARRHY

MDC

10:9312

Non-Respiratory Sinus Arrhythmia

MDC_ECG_RHY_NON_RESP_ARRHY

MDC

10:9328

Wandering Sinus Pacemaker within the sinus node

MDC_ECG_RHY_WANDP_ARRHY

MDC

10:9344

Wandering Pacemaker between the sinus node and the A-V node

MDC_ECG_RHY_WANDPAV_ARRHY

MDC

10:9360

Atrial Ectopic Rhythm

MDC_ECG_RHY_ATR_ECT_RHY

MDC

10:9376

Atrial Bigeminy

MDC_ECG_RHY_ATR_BIGEM

MDC

10:9392

Atrial Tachycardia

MDC_ECG_RHY_ATR_TACHY

MDC

10:9408

Paroxsysmal Atrial Tachycardia

MDC_ECG_RHY_ATR_TACHY_PAROX

MDC

10:9424

Multifocal Atrial Tachycardia

MDC_ECG_RHY_ATR_TACHY_MF

MDC

10:9440

Automatic Atrial Tachycardia

MDC_ECG_RHY_ATR_TACHY_AUTO

MDC

10:9456

Atrial flutter

MDC_ECG_RHY_ATR_FLUT

MDC

10:9472

Atrial fibrillation

MDC_ECG_RHY_ATR_FIB

MDC

10:9488

Supraventricular (atrial or junctional) Ectopic Rhythm

MDC_ECG_RHY_SV_ECT_RHY

MDC

10:9504

Supraventricular Tachycardia (atrial or junctional)

MDC_ECG_RHY_SV_TACHY

MDC

10:9520

Supraventricular Paroxsysmal Tachycardia

MDC_ECG_RHY_SV_TACHY_PAROX

MDC

10:9536

AV junctional (nodal) rhythm

MDC_ECG_RHY_JUNC_RHY

MDC

10:9552

AV junctional (nodal) escape rhythm

MDC_ECG_RHY_JUNC_ESC_BEATS

MDC

10:9568

Accelerated AV junctional (nodal) rhythm

MDC_ECG_RHY_JUNC_ACCEL

MDC

10:9584

Junctional Tachycardia

MDC_ECG_RHY_JUNC_TACHY

MDC

10:9600

AV reciprocating tachycardia

MDC_ECG_RHY_AV_TACHY_RECIP

MDC

10:9616

Reentrant AV nodal tachycardia

MDC_ECG_RHY_AV_TACHY_REENTRANT

MDC

10:9632

First Degree AV Block

MDC_ECG_RHY_AV_HEART_BLK_DEG_1

MDC

10:9648

Second Degree AV Block

MDC_ECG_RHY_AV_HEART_BLK_DEG_2

MDC

10:9664

Second Degree AV Block Type I (Wenckebach, or Mobitz Type I)

MDC_ECG_RHY_AV_HEART_BLK_DEG_2_I

MDC

10:9680

Second Degree AV Block Type II (Mobitz Type II)

MDC_ECG_RHY_AV_HEART_BLK_DEG_2_II

MDC

10:9696

Third Degree AV Block (complete AV block)

MDC_ECG_RHY_AV_HEART_BLK_DEG_3

MDC

10:9712

AV Dissociation

MDC_ECG_RHY_AV_DISSOC

MDC

10:9728

AV dissociation with interference

MDC_ECG_RHY_AV_DISSOC_INT

MDC

10:9744

Isorhythmic AV dissociation

MDC_ECG_RHY_AV_DISSOC_ISO

MDC

10:9760

Complete AV dissociation

MDC_ECG_RHY_AV_DISSOC_COMP

MDC

10:9776

First Degree SA Block

MDC_ECG_RHY_SA_HEART_BLK_DEG_1

MDC

10:9792

Second Degree SA Block Type I (Wenckebach)

MDC_ECG_RHY_SA_HEART_BLK_DEG_2_I

MDC

10:9808

Second Degree SA Block Type II

MDC_ECG_RHY_SA_HEART_BLK_DEG_2_II

MDC

10:9824

Third Degree SA Block (complete SA block)

MDC_ECG_RHY_SA_HEART_BLK_DEG_3

MDC

10:9840

Ventricular rhythm

MDC_ECG_RHY_V_RHY

MDC

10:9856

Idioventricular (ventricular escape) rhythm

MDC_ECG_RHY_V_IDIO_RHY

MDC

10:9872

Ventricular Parasystole

MDC_ECG_RHY_V_PARA

MDC

10:9888

Accelerated idioventricular rhythm

MDC_ECG_RHY_V_AIVR

MDC

10:9904

Slow Ventricular Tachycardia (Idioventricular Tachycardia)

MDC_ECG_RHY_V_IDIO_TACHY

MDC

10:9920

Ventricular Bigeminy

MDC_ECG_RHY_V_BIGEM

MDC

10:9936

Ventricular Trigeminy

MDC_ECG_RHY_V_TRIGEM

MDC

10:9952

Ventricular Couplet

MDC_ECG_RHY_V_P_C_CPLT

MDC

10:9968

Ventricular Run

MDC_ECG_RHY_V_P_C_RUN

MDC

10:9984

Ventricular Tachycardia (nonparoxysmal)

MDC_ECG_RHY_V_TACHY

MDC

10:10000

Ventricular Flutter

MDC_ECG_RHY_V_FLUT

MDC

10:10016

Ventricular Fibrillation

MDC_ECG_RHY_V_FIB

MDC

10:10032

Nonsustained Ventricular Tachycardia (paroxysmal)

MDC_ECG_RHY_V_TACHY_PAROX

MDC

10:10048

Sustained Monomorphic Ventricular Tachycardia

MDC_ECG_RHY_V_TACHY_MONO

MDC

10:10064

Polymorphic Ventricular Tachycardia

MDC_ECG_RHY_V_TACHY_POLY

MDC

10:10080

Torsades de Pointes Ventricular Tachycardia

MDC_ECG_RHY_V_TACHY_TDP

MDC

10:10096

pre-excitation

MDC_ECG_RHY_PREX

MDC

10:10112

Wolf-Parkinson-White syndrome

MDC_ECG_RHY_WPW_UNK

MDC

10:10128

Wolf-Parkinson type A

MDC_ECG_RHY_WPW_A

MDC

10:10144

Wolf-Parkinson type B

MDC_ECG_RHY_WPW_B

MDC

10:10160

Lown-Ganong-Levine syndrome

MDC_ECG_RHY_LGL

MDC

10:10336

Asystole

MDC_ECG_RHY_ASYSTOLE

MDC

10:10352

Irregular rhythm

MDC_ECG_RHY_IRREG

MDC

10:10368

Low Heart Rate Variability

MDC_ECG_RHY_LHRV

MDC

10:10416

T-wave alternans

MDC_ECG_RHY_TALT

MDC

10:10432

Bradycardia

MDC_ECG_RHY_BRADY

MDC

10:10448

Calibration signal (sustained)

MDC_ECG_RHY_CALS

MDC

10:10176

Atrial Demand Mode Pacing

MDC_ECG_RHY_EPADM

MDC

10:10240

Ventricular Demand Mode Pacing

MDC_ECG_RHY_EPVDM

MDC

10:10304

Anti-Tachycardia Pacing

MDC_ECG_RHY_EPAVT


Note

A prior version of this Context Group used codes from the SCP-ECG vocabulary.

DICOM PS3.16 2024c - Content Mapping Resource