DICOM PS3.16 2024c - Content Mapping Resource

CID 3201 Indications for Stress Test

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

IndicationsForStressTest

FHIR Keyword:

dicom-cid-3201-IndicationsForStressTest

Type:

Extensible

Version:

20240611

UID:

1.2.840.10008.6.1.756

Table CID 3201. Indications for Stress Test

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

SCT

29857009

Chest Pain

F-37000

C0008031

SCT

262068006

Pre-operative

R-413C5

C0445204

SCT

53741008

Coronary Artery Disease

D3-13040

C0010054

SCT

84114007

Heart failure

D3-16000

C0018801

SCT

171224000

Heart disease risk factors

F-03C97

C0420044

SCT

267036007

Dyspnea

F-201B3

C0013404

SCT

371822007

Post PTCA

R-0039D

C1299450

SCT

399261000

History of CABG

G-03A5

C1275842

SCT

165084003

Abnormal exercise tolerance test

F-00103

C0149612

SCT

102594003

Abnormal ECG

F-38002

C0522055

SCT

44808001

Arrhythmia

D3-30000

C0264886

SCT

194828000

Angina pectoris

D3-13012

C0002962

SCT

38341003

Hypertension

D3-02000

C0020538

SCT

80313002

Palpitations

F-37150

C0030252

SCT

6456007

Supraventricular tachycardia

D3-31290

C0039240

SCT

271594007

Syncope

D3-00006

C0039070

SCT

399211009

History of Myocardial Infarction

G-03AA

C1275835

SCT

63467002

Left bundle branch block

D3-33120

C0023211

SCT

368009

Valvular heart disease

D3-10800

C0018824

SCT

429060002

Occupational requirement

P7-00044

C1997084


DICOM PS3.16 2024c - Content Mapping Resource