DICOM PS3.16 2024c - Content Mapping Resource

L Correspondence of Anatomic Region Codes and Body Part Examined Defined Terms

This Annex defines a correspondence between the codes used in Context Groups for Anatomic Region Sequence (0008,2218) and Body Part Examined (0018,0015), as well as providing a list of the Defined Terms for Body Part Examined (0018,0015), for human use in Table L-1 and for large animal use in Table L-2 and for small animal use in Table L-3. In addition, Table L-5 summarizes whether or not selected anatomic concepts need a laterality modifier (as opposed to being unpaired, or already incorporating laterality as a precoordinated concept).

Note

  1. The tables in this Annex contain the union of a large variety of codes suitable for different applications and modalities, including cross-sectional, projectional and visible light. as such, only a subset will be appropriate for any specific application.

  2. Values for Body Part Examined are limited by the CS VR length restriction to 16 characters in length and hence are somewhat contrived. Some inconsistency in abbreviations may be apparent but this largely reflects historical usage or clinically well recognized usage. No spaces or underscores are used, and singular rather than plural forms are used.

Table L-1. Corresponding Codes and Terms for Human Use

Coding Scheme Designator

Code Value

Code Meaning

Body Part Examined

SNOMED-RT ID (Retired)

FMA Code Value

UMLS Concept UniqueID

SCT

818981001

Abdomen

ABDOMEN

SCT

818982008

Abdomen and Pelvis

ABDOMENPELVIS

SCT

7832008

Abdominal aorta

ABDOMINALAORTA

T-42500

SCT

85856004

Acromioclavicular joint

ACJOINT

T-15420

SCT

23451007

Adrenal gland

ADRENAL

T-B3000

SCT

77012006

Amniotic fluid

AMNIOTICFLUID

T-F1320

SCT

70258002

Ankle joint

ANKLE

T-15750

SCT

128585006

Anomalous pulmonary vein

T-48503

SCT

128553008

Antecubital vein

ANTECUBITALV

T-49215

SCT

194996006

Anterior cardiac vein

ANTCARDIACV

T-48403

SCT

60176003

Anterior cerebral artery

ACA

T-45540

50028

SCT

8012006

Anterior communicating artery

ANTCOMMA

T-45530

SCT

17388009

Anterior spinal artery

ANTSPINALA

T-45730

SCT

68053000

Anterior tibial artery

ANTTIBIALA

T-47700

SCT

53505006

Anus

T-59900

SCT

110612005

Anus, rectum and sigmoid colon

ANUSRECTUMSIGMD

T-59490

SCT

15825003

Aorta

AORTA

T-42000

SCT

57034009

Aortic arch

AORTICARCH

T-42300

SCT

128551005

Aortic fistula

D3-81922

SCT

128564006

Apex of left ventricle

T-32602

SCT

86598002

Apex of Lung

T-280A0

SCT

128565007

Apex of right ventricle

T-32502

SCT

66754008

Appendix

APPENDIX

T-59200

SCT

51114001

Artery

ARTERY

T-41000

SCT

54247002

Ascending aorta

ASCAORTA

T-42100

SCT

9040008

Ascending colon

ASCENDINGCOLON

T-59420

SCT

59652004

Atrium

T-32100

SCT

91470000

Axilla

AXILLA

T-D8104

SCT

67937003

Axillary Artery

AXILLARYA

T-47100

SCT

68705008

Axillary vein

AXILLARYV

T-49110

SCT

72107004

Azygos vein

AZYGOSVEIN

T-48340

SCT

77568009

Back

BACK

T-D2100

SCT

128981007

Baffle

A-00203

SCT

59011009

Basilar artery

BASILARA

T-45800

SCT

28273000

Bile duct

BILEDUCT

T-60610

SCT

34707002

Biliary tract

BILIARYTRACT

T-60600

C0005423

SCT

89837001

Bladder

BLADDER

T-74000

SCT

110837003

Bladder and urethra

BLADDERURETHRA

T-DD123

SCT

91830000

Body conduit

T-D00AB

SCT

72001000

Bone of lower limb

T-12700

SCT

371195002

Bone of upper limb

T-D0821

SCT

128548003

Boyd's perforating vein

T-49424

SCT

17137000

Brachial artery

BRACHIALA

T-47160

SCT

20115005

Brachial vein

BRACHIALV

T-49350

SCT

12738006

Brain

BRAIN

T-A0100

SCT

76752008

Breast

BREAST

T-04000

SCT

34411009

Broad ligament

T-D6500

SCT

955009

Bronchus

BRONCHUS

T-26000

SCT

60819002

Buccal region of face

T-D1206

SCT

46862004

Buttock

BUTTOCK

T-D2600

SCT

80144004

Calcaneus

CALCANEUS

T-12770

SCT

53840002

Calf of leg

CALF

T-D9440

SCT

2334006

Calyx

T-72100

SCT

69105007

Carotid Artery

CAROTID

T-45010

SCT

21479005

Carotid bulb

BULB

T-45170

50094

SCT

57850000

Celiac artery

CELIACA

T-46400

50737

SCT

20699002

Cephalic vein

CEPHALICV

T-49240

SCT

113305005

Cerebellum

CEREBELLUM

T-A6000

SCT

88556005

Cerebral artery

CEREBRALA

T-45510

SCT

372073000

Cerebral hemisphere

CEREBHEMISPHERE

T-A010F

SCT

122494005

Cervical spine

CSPINE

T-11501

SCT

1217257000

Cervico-thoracic spine

CTSPINE

SCT

71252005

Cervix

CERVIX

T-83200

SCT

60819002

Cheek

CHEEK

T-D1206

SCT

43799004

Chest

CHEST

SCT

416775004

Chest, Abdomen and Pelvis

CHESTABDPELVIS

R-FAB56

SCT

416550000

Chest and Abdomen

CHESTABDOMEN

R-FAB55

SCT

80621003

Choroid plexus

CHOROIDPLEXUS

T-A1900

61934

SCT

11279006

Circle of Willis

CIRCLEOFWILLIS

T-45520

SCT

51299004

Clavicle

CLAVICLE

T-12310

SCT

64688005

Coccyx

COCCYX

T-11BF0

SCT

71854001

Colon

COLON

T-59300

SCT

253276007

Common atrium

D4-31005

SCT

79741001

Common bile duct

COMMONBILEDUCT

T-64500

C0009437

SCT

32062004

Common carotid artery

CCA

T-45100

SCT

181347005

Common femoral artery

CFA

T-47402

323778

SCT

397363009

Common femoral vein

CFV

G-035B

323829

SCT

73634005

Common iliac artery

COMILIACA

T-46710

SCT

46027005

Common iliac vein

COMILIACV

T-48920

SCT

45503006

Common ventricle

D4-31120

SCT

128555001

Congenital coronary artery fistula to left atrium

D4-32504

SCT

128556000

Congenital coronary artery fistula to left ventricle

D4-32506

SCT

128557009

Congenital coronary artery fistula to right atrium

D4-32509

SCT

128558004

Congenital coronary artery fistula to right ventricle

D4-32510

SCT

111289009

Pulmonary arteriovenous fistula

D3-40208

SCT

28726007

Cornea

CORNEA

T-AA200

SCT

41801008

Coronary artery

CORONARYARTERY

T-43000

SCT

90219004

Coronary sinus

CORONARYSINUS

T-48410

SCT

128320002

Cranial venous system

T-A0191

SCT

32672002

Descending aorta

DESCAORTA

T-42400

SCT

32622004

Descending colon

DESCENDINGCOLON

T-59460

SCT

128554002

Dodd's perforating vein

T-49429

SCT

38848004

Duodenum

DUODENUM

T-58200

SCT

117590005

Ear

EAR

T-AB001

SCT

16953009

Elbow joint

ELBOW

T-15430

SCT

51114001

Endo-arterial

ENDOARTERIAL

T-41000

SCT

80891009

Endo-cardiac

ENDOCARDIAC

T-32000

SCT

32849002

Endo-esophageal

ENDOESOPHAGEAL

T-56000

SCT

2739003

Endometrium

ENDOMETRIUM

T-83400

SCT

53342003

Endo-nasal

ENDONASAL

T-21300

SCT

18962004

Endo-nasopharyngeal

ENDONASOPHARYNYX

T-23050

SCT

34402009

Endo-rectal

ENDORECTAL

T-59600

SCT

64033007

Endo-renal

ENDORENAL

T-71000

SCT

87953007

Endo-ureteric

ENDOURETERIC

T-73000

SCT

13648007

Endo-urethral

ENDOURETHRAL

T-75000

SCT

76784001

Endo-vaginal

ENDOVAGINAL

T-82000

SCT

59820001

Endo-vascular

ENDOVASCULAR

T-40000

SCT

29092000

Endo-venous

ENDOVENOUS

T-48000

SCT

48367006

Endo-vesical

ENDOVESICAL

T-74250

SCT

38266002

Entire body

WHOLEBODY

T-D0010

SCT

87644002

Epididymis

EPIDIDYMIS

T-95000

18255

SCT

27947004

Epigastric region

EPIGASTRIC

T-D4200

SCT

32849002

Esophagus

ESOPHAGUS

T-56000

SCT

110861005

Esophagus, stomach and duodenum

T-DD163

SCT

84301002

External auditory canal

EAC

T-AB200

SCT

22286001

External carotid artery

ECA

T-45200

SCT

113269004

External iliac artery

EXTILIACA

T-46910

SCT

63507001

External iliac vein

EXTILIACV

T-48930

SCT

71585003

External jugular vein

EXTJUGV

T-48160

13110

C0226543

SCT

66019005

Extremity

EXTREMITY

T-D0300

SCT

81745001

Eye

EYE

T-AA000

SCT

80243003

Eyelid

EYELID

T-AA810

SCT

371398005

Eye region

T-D0801

SCT

89545001

Face

FACE

T-D1200

SCT

23074001

Facial artery

FACIALA

T-45240

SCT

91397008

Facial bones

T-11196

SCT

7657000

Femoral artery

FEMORALA

T-47400

SCT

83419000

Femoral vein

FEMORALV

T-49410

SCT

71341001

Femur

FEMUR

T-12710

Fetal arm

FETALARM

Fetal digit

FETALDIGIT

Fetal heart

FETALHEART

63931

Fetal leg

FETALLEG

Fetal pole

FETALPOLE

SCT

87342007

Fibula

FIBULA

T-12750

SCT

7569003

Finger

FINGER

T-D8800

SCT

58602004

Flank

FLANK

T-D2310

SCT

79361005

Fontanel of skull

FONTANEL

T-15200

SCT

56459004

Foot

FOOT

T-D9700

SCT

14975008

Forearm

FOREARM

T-D8500

SCT

35918002

Fourth ventricle

4THVENTRICLE

T-A1820

SCT

28231008

Gallbladder

GALLBLADDER

T-63000

SCT

110568007

Gastric vein

GASTRICV

T-48820

SCT

128559007

Genicular artery

GENICULARA

T-47490

SCT

300571009

Gestational sac

GESTSAC

F-03FC9

SCT

46862004

Gluteal region

GLUTEAL

T-D2600

SCT

5928000

Great cardiac vein

T-48420

SCT

60734001

Great saphenous vein

GSV

T-49530

21376

SCT

85562004

Hand

HAND

T-D8700

SCT

69536005

Head

HEAD

T-D1100

SCT

774007

Head and Neck

HEADNECK

T-D1000

SCT

80891009

Heart

HEART

T-32000

SCT

76015000

Hepatic artery

HEPATICA

T-46420

SCT

8993003

Hepatic vein

HEPATICV

T-48720

SCT

24136001

Hip joint

HIP

T-15710

SCT

85050009

Humerus

HUMERUS

T-12410

SCT

128560002

Hunterian perforating vein

T-4942A

SCT

11708003

Hypogastric region

HYPOGASTRIC

T-D4240

SCT

81502006

Hypopharynx

HYPOPHARYNX

T-55300

SCT

34516001

Ileum

ILEUM

T-58600

SCT

299716001

Iliac and/or femoral artery

T-41068

SCT

10293006

Iliac artery

ILIACA

T-46700

SCT

244411005

Iliac vein

ILIACV

T-4940E

SCT

22356005

Ilium

ILIUM

T-12340

SCT

195416006

Inferior cardiac vein

T-484A4

SCT

51249003

Inferior left pulmonary vein

T-48540

SCT

33795007

Inferior mesenteric artery

INFMESA

T-46520

SCT

113273001

Inferior right pulmonary vein

T-48520

SCT

64131007

Inferior vena cava

INFVENACAVA

T-48710

SCT

26893007

Inguinal region

INGUINAL

T-D7000

SCT

12691009

Innominate artery

INNOMINATEA

T-46010

SCT

8887007

Innominate vein

INNOMINATEV

T-48620

SCT

361078006

Internal Auditory Canal

IAC

T-AB959

SCT

86117002

Internal carotid artery

ICA

T-45300

SCT

90024005

Internal iliac artery

INTILIACA

T-46740

SCT

12123001

Internal jugular vein

INTJUGULARV

T-48170

SCT

69327007

Internal mammary artery

INTMAMMARYA

T-46200

SCT

818987002

Intra-abdominopelvic

SCT

131183008

Intra-articular

G-A15A

SCT

1101003

Intracranial

INTRACRANIAL

T-D1400

SCT

32849002

Intra-esophageal

T-56000

SCT

816989007

Intra-pelvic

SCT

43799004

Intra-thoracic

SCT

661005

Jaw region

JAW

T-D1213

SCT

21306003

Jejunum

JEJUNUM

T-58400

SCT

39352004

Joint

JOINT

T-15001

SCT

128563000

Juxtaposed atrial appendage

D4-31052

SCT

64033007

Kidney

KIDNEY

T-71000

SCT

72696002

Knee

KNEE

T-D9200

SCT

59749000

Lacrimal artery

LACRIMALA

T-45410

SCT

128979005

Lacrimal artery of right eye

T-45416

SCT

14742008

Large intestine

LARGEINTESTINE

T-59000

SCT

4596009

Larynx

LARYNX

T-24100

SCT

66720007

Lateral Ventricle

LATVENTRICLE

T-A1650

78448

SCT

82471001

Left atrium

LATRIUM

T-32300

SCT

33626005

Left auricular appendage

T-32310

SCT

113270003

Left femoral artery

LFEMORALA

T-47420

SCT

273202007

Left hepatic vein

LHEPATICV

T-48727

14339

SCT

133945003

Left hypochondriac region

LHYPOCHONDRIAC

T-D4211

SCT

85119005

Left inguinal region

LINGUINAL

T-D7020

SCT

68505006

Left lower quadrant of abdomen

LLQ

T-D4140

SCT

1017210004

Left lumbar region

LLUMBAR

SCT

70253006

Left portal vein

LPORTALV

T-48814

15415

SCT

50408007

Left pulmonary artery

LPULMONARYA

T-44400

SCT

86367003

Left upper quadrant of abdomen

LUQ

T-D4130

SCT

87878005

Left ventricle

LVENTRICLE

T-32600

SCT

70238003

Left ventricle inflow

T-32640

SCT

13418002

Left ventricle outflow tract

T-32650

SCT

113264009

Lingual artery

LINGUALA

T-45230

SCT

10200004

Liver

LIVER

T-62000

SCT

19100000

Lower inner quadrant of breast

T-04003

SCT

30021000

Lower leg

LOWERLEG

T-D9400

SCT

61685007

Lower limb

LOWERLIMB

T-D9000

SCT

33564002

Lower outer quadrant of breast

T-04005

SCT

34635009

Lumbar artery

LUMBARA

T-46960

SCT

52612000

Lumbar region

LUMBAR

T-D2300

SCT

122496007

Lumbar spine

LSPINE

T-11503

SCT

1217253001

Lumbo-sacral spine

LSSPINE

SCT

91747007

Lumen of blood vessel

LUMEN

T-40230

SCT

39607008

Lung

LUNG

T-28000

SCT

91609006

Mandible

MANDIBLE

T-11180

SCT

59066005

Mastoid bone

MASTOID

T-11133

SCT

70925003

Maxilla

MAXILLA

T-11170

SCT

72410000

Mediastinum

MEDIASTINUM

T-D3300

SCT

86570000

Mesenteric artery

MESENTRICA

T-46500

SCT

128583004

Mesenteric vein

MESENTRICV

T-4884A

SCT

17232002

Middle cerebral artery

MCA

T-45600

50079

SCT

273099000

Middle hepatic vein

MIDHEPATICV

T-48726

14340

SCT

243977002

Morisons pouch

MORISONSPOUCH

T-D4434

SCT

123851003

Mouth

MOUTH

T-D0662

SCT

102292000

Muscle of lower limb

T-14668

SCT

30608006

Muscle of upper limb

T-13600

SCT

74386004

Nasal bone

T-11149

SCT

360955006

Nasopharynx

NASOPHARYNX

T-2300C

SCT

45048000

Neck

NECK

T-D1600

SCT

416319003

Neck, Chest, Abdomen and Pelvis

NECKCHESTABDPELV

R-FAB54

SCT

416152001

Neck, Chest and Abdomen

NECKCHESTABDOMEN

R-FAB53

SCT

417437006

Neck and Chest

NECKCHEST

R-FAB52

SCT

45206002

Nose

NOSE

T-21000

SCT

31145008

Occipital artery

OCCPITALA

T-45250

SCT

32114007

Occipital vein

OCCIPTALV

T-48214

SCT

113346000

Omental bursa

T-D4450

SCT

27398004

Omentum

T-D4600

SCT

53549008

Ophthalmic artery

OPHTHALMICA

T-45400

SCT

55024004

Optic canal

OPTICCANAL

T-11102

SCT

363654007

Orbital structure

ORBIT

T-D14AE

SCT

15497006

Ovary

OVARY

T-87000

SCT

15776009

Pancreas

PANCREAS

T-65000

SCT

69930009

Pancreatic duct

PANCREATICDUCT

T-65010

SCT

110621006

Pancreatic duct and bile duct systems

PANCBILEDUCT

T-65600

SCT

2095001

Paranasal sinus

T-22000

SINUS

SCT

91691001

Parasternal

PARASTERNAL

T-D3136

SCT

111002

Parathyroid

PARATHYROID

T-B7000

SCT

45289007

Parotid gland

PAROTID

T-61100

SCT

64234005

Patella

PATELLA

T-12730

SCT

83330001

Patent ductus arteriosus

D4-32012

SCT

816092008

Pelvis

PELVIS

SCT

1231522001

Pelvis and lower extremities

PELVISLOWEXTREMT

SCT

282044005

Penile artery

PENILEA

T-46807

66318

SCT

18911002

Penis

PENIS

T-91000

SCT

38864007

Perineum

PERINEUM

T-D2700

SCT

8821006

Peroneal artery

PERONEALA

T-47630

SCT

706342009

Phantom

PHANTOM

R-FE0C7

C0282611

SCT

54066008

Pharynx

PHARYNX

T-55000

SCT

312535008

Pharynx and larynx

PHARYNXLARYNX

T-20101

SCT

78067005

Placenta

PLACENTA

T-F1100

SCT

43899006

Popliteal artery

POPLITEALA

T-47500

SCT

32361000

Popliteal fossa

POPLITEALFOSSA

T-D9310

SCT

56849005

Popliteal vein

POPLITEALV

T-49650

44327

SCT

32764006

Portal vein

PORTALV

T-48810

66645

SCT

70382005

Posterior cerebral artery

PCA

T-45900

50583

SCT

43119007

Posterior communicating artery

POSCOMMA

T-45320

SCT

128569001

Posterior medial tributary

T-49535

SCT

13363002

Posterior tibial artery

POSTIBIALA

T-47600

SCT

14944004

Primitive aorta

T-F7001

SCT

91707000

Primitive pulmonary artery

T-F7040

SCT

31677005

Profunda femoris artery

PROFFEMA

T-47440

20741

SCT

23438002

Profunda femoris vein

PROFFEMV

T-49660

51041

SCT

41216001

Prostate

PROSTATE

T-92000

SCT

81040000

Pulmonary artery

PULMONARYA

T-44000

SCT

128584005

Pulmonary artery conduit

D4-33142

SCT

128586007

Pulmonary chamber of cor triatriatum

T-32190

SCT

122972007

Pulmonary vein

PULMONARYV

T-48581

SCT

128566008

Pulmonary vein confluence

D4-33512

SCT

128567004

Pulmonary venous atrium

D4-33514

SCT

45631007

Radial artery

RADIALA

T-47300

SCT

62413002

Radius

RADIUS

T-12420

SCT

110535000

Radius and ulna

RADIUSULNA

T-12403

SCT

53843000

Rectouterine pouch

CULDESAC

T-D6407

SCT

34402009

Rectum

RECTUM

T-59600

SCT

2841007

Renal artery

RENALA

T-46600

SCT

25990002

Renal pelvis

T-72000

SCT

56400007

Renal vein

RENALV

T-48740

SCT

82849001

Retroperitoneum

RETROPERITONEUM

T-D4900

SCT

113197003

Rib

RIB

T-11300

SCT

73829009

Right atrium

RATRIUM

T-32200

SCT

68300000

Right auricular appendage

T-32210

SCT

69833005

Right femoral artery

RFEMORALA

T-47410

SCT

272998002

Right hepatic vein

RHEPATICV

T-48725

14338

SCT

133946002

Right hypochondriac region

RHYPOCHONDRIAC

T-D4212

SCT

37117007

Right inguinal region

RINGUINAL

T-D7010

SCT

48544008

Right lower quadrant of abdomen

RLQ

T-D4120

SCT

1017211000

Right lumbar region

RLUMBAR

SCT

73931004

Right portal vein

RPORTALV

T-48813

15414

SCT

78480002

Right pulmonary artery

RPULMONARYA

T-44200

SCT

50519007

Right upper quadrant of abdomen

RUQ

T-D4110

SCT

53085002

Right ventricle

RVENTRICLE

T-32500

SCT

8017000

Right ventricle inflow

T-32540

SCT

44627009

Right ventricle outflow tract

T-32550

SCT

39723000

Sacroiliac joint

SIJOINT

T-15680

SCT

54735007

Sacrum

SSPINE

T-11AD0

SCT

128587003

Saphenofemoral junction

SFJ

T-D930A

SCT

362072009

Saphenous vein

SAPHENOUSV

T-4940B

C0036186

SCT

41695006

Scalp

SCALP

T-D1160

SCT

79601000

Scapula

SCAPULA

T-12280

SCT

18619003

Sclera

SCLERA

T-AA110

SCT

20233005

Scrotum

SCROTUM

T-98000

SCT

42575006

Sella turcica

SELLA

T-D1460

SCT

64739004

Seminal vesicle

SEMVESICLE

T-93000

19386

SCT

58742003

Sesamoid bones of foot

SESAMOID

T-12980

SCT

16982005

Shoulder

SHOULDER

T-D2220

SCT

60184004

Sigmoid colon

SIGMOID

T-59470

SCT

89546000

Skull

SKULL

T-11100

SCT

30315005

Small intestine

SMALLINTESTINE

T-58000

SCT

2748008

Spinal cord

SPINALCORD

T-A7010

SCT

421060004

Spine

SPINE

T-D04FF

SCT

78961009

Spleen

SPLEEN

T-C3000

SCT

22083002

Splenic artery

SPLENICA

T-46460

SCT

35819009

Splenic vein

SPLENICV

T-48890

SCT

7844006

Sternoclavicular joint

SCJOINT

T-15610

SCT

56873002

Sternum

STERNUM

T-11210

SCT

69695003

Stomach

STOMACH

T-57000

SCT

36765005

Subclavian artery

SUBCLAVIANA

T-46100

SCT

9454009

Subclavian vein

SUBCLAVIANV

T-48330

SCT

19695001

Subcostal

SUBCOSTAL

T-D4210

SCT

5713008

Submandibular area

T-D1603

SCT

54019009

Submandibular gland

SUBMANDIBULAR

T-61300

SCT

170887008

Submental

T-D161E

SCT

5076001

Subxiphoid

T-D3213

SCT

181349008

Superficial femoral artery

SFA

T-47403

323777

SCT

397364003

Superficial femoral vein

SFV

G-035A

SCT

15672000

Superficial temporal artery

T-45270

SCT

43863001

Superior left pulmonary vein

LSUPPULMONARYV

T-48530

SCT

42258001

Superior mesenteric artery

SMA

T-46510

SCT

8629005

Superior right pulmonary vein

RSUPPULMONARYV

T-48510

SCT

72021004

Superior thyroid artery

SUPTHYROIDA

T-45210

SCT

48345005

Superior vena cava

SVC

T-48610

SCT

77621008

Supraclavicular region of neck

SUPRACLAVICULAR

T-D1620

SCT

11708003

Suprapubic region

SUPRAPUBIC

T-D4240

SCT

26493002

Suprasternal notch

T-11218

SCT

128589000

Systemic collateral artery to lung

T-44007

SCT

128568009

Systemic venous atrium

D4-33516

SCT

27949001

Tarsal joint

T-15770

SCT

53620006

Temporomandibular joint

TMJ

T-15290

SCT

40689003

Testis

TESTIS

T-94000

SCT

42695009

Thalamus

THALAMUS

T-A4000

62007

SCT

68367000

Thigh

THIGH

T-D9100

SCT

49841001

Third ventricle

3RDVENTRICLE

T-A1740

SCT

113262008

Thoracic aorta

THORACICAORTA

T-42070

SCT

122495006

Thoracic spine

TSPINE

T-11502

SCT

1217256009

Thoraco-lumbar spine

TLSPINE

SCT

43799004

Thorax

THORAX

SCT

76505004

Thumb

THUMB

T-D8810

SCT

9875009

Thymus

THYMUS

T-C8000

SCT

69748006

Thyroid

THYROID

T-B6000

SCT

12611008

Tibia

TIBIA

T-12740

SCT

110536004

Tibia and fibula

TIBIAFIBULA

T-12701

SCT

29707007

Toe

TOE

T-D9800

SCT

21974007

Tongue

TONGUE

T-53000

SCT

44567001

Trachea

TRACHEA

T-25000

SCT

110726009

Trachea and bronchus

TRACHEABRONCHUS

T-DD006

SCT

485005

Transverse colon

TRANSVERSECOLON

T-59440

SCT

61959006

Truncus arteriosus communis

D4-31400

SCT

57850000

Truncus coeliacus

T-46400

SCT

23416004

Ulna

ULNA

T-12430

SCT

44984001

Ulnar artery

ULNARA

T-47200

SCT

50536004

Umbilical artery

UMBILICALA

T-F1810

SCT

90290004

Umbilical region

UMBILICAL

T-D4230

SCT

284639000

Umbilical vein

UMBILICALV

T-48832

SCT

40983000

Upper arm

UPPERARM

T-D8200

SCT

77831004

Upper inner quadrant of breast

T-04002

SCT

53120007

Upper limb

UPPERLIMB

T-D8000

SCT

76365002

Upper outer quadrant of breast

T-04004

SCT

431491007

Upper urinary tract

UPRURINARYTRACT

T-7000B

SCT

87953007

Ureter

URETER

T-73000

SCT

13648007

Urethra

URETHRA

T-75000

SCT

35039007

Uterus

UTERUS

T-83000

SCT

110639002

Uterus and fallopian tubes

T-88920

SCT

76784001

Vagina

VAGINA

T-82000

SCT

118375008

Vascular graft

A-04140

SCT

29092000

Vein

VEIN

T-48000

SCT

34340008

Venous network

T-48003

SCT

21814001

Ventricle

T-32400

SCT

85234005

Vertebral artery

VERTEBRALA

T-45700

SCT

110517009

Vertebral column and cranium

T-11011

SCT

45292006

Vulva

VULVA

T-81000

SCT

74670003

Wrist joint

WRIST

T-15460

SCT

13881006

Zygoma

ZYGOMA

T-11166


Note

In prior versions of this table, different codes were used for some concepts; see PS3.16-2011.

Table L-2. Corresponding Codes and Terms for Large Animals

Coding Scheme Designator

Code Value

Code Meaning

Body Part Examined

SNOMED-RT ID (Retired)

FMA Code Value

UMLS Concept UniqueID

SCT

818981001

Abdomen

ABDOMEN

SCT

42694008

All legs

LEGS

T-D8030

SCT

62555009

Atlantal-axial joint

ATLANTOAXIAL

T-15317

SCT

20292002

Atlanto-occipital joint

ATLANTOOCCIPITAL

T-15311

SCT

89837001

Bladder

BLADDER

T-74000

SCT

82474009

Calcaneal tubercle

T-12771

SCT

8205005

Carpus

CARPUS

T-D8600

SCT

122494005

Cervical spine

CSPINE

T-11501

SCT

1217257000

Cervico-thoracic spine

CTSPINE

SCT

816094009

Chest

CHEST

SCT

416550000

Chest and Abdomen

CHESTABDOMEN

R-FAB55

SCT

18149002

Coccygeal vertrebrae

TAIL

T-11B00

SCT

71854001

Colon

COLON

T-59300

SCT

82680008

Digit

DIGIT

T-D0310

UMLS

C3669027

Distal phalanx

DISTALPHALANX

C3669027

SCT

16953009

Elbow joint

ELBOW

T-15430

SCT

38266002

Entire body

WHOLEBODY

T-D0010

SCT

32849002

Esophagus

ESOPHAGUS

T-56000

SCT

71341001

Femur

FEMUR

T-12710

SCT

13190002

Fetlock of forelimb

FOREFETLOCK

T-D8640

SCT

113351006

Fetlock of hindlimb

HINDFETLOCK

T-D9540

SCT

87342007

Fibula

FIBULA

T-12750

SCT

419176008

Forefoot

FOREFOOT

T-D04F2

SCT

55060009

Frontal sinus

FRONTALSINUS

T-22200

SCT

416804009

Hindfoot

HINDFOOT

T-D9713

SCT

24136001

Hip joint

HIP

T-15710

SCT

85050009

Humerus

HUMERUS

T-12410

SCT

122496007

Lumbar spine

LSPINE

T-11503

SCT

1217253001

Lumbo-sacral spine

LSSPINE

SCT

91609006

Mandible

JAW

T-11180

SCT

88176008

Mandibular dental arch

T-54170

SCT

442274007

Mandibular incisor teeth

T-540EE

SCT

39481002

Maxillary dental arch

T-54160

SCT

442100006

Maxillary incisor teeth

T-540ED

SCT

36455000

Metacarpus

METACARPUS

T-12540

SCT

280711000

Metatarsus

METATARSUS

T-12847

SCT

2095001

Nasal sinus

T-22000

SCT

30518006

Navicular of forefoot

FORENAVICULAR

T-12450

SCT

75772009

Navicular of hindfoot

HINDNAVICULAR

T-12800

SCT

363654007

Orbital structure

ORBIT

T-D14AE

SCT

31329001

Pastern of forefoot

FOREPASTERN

T-D8650

SCT

18525008

Pastern of hindfoot

HINDPASTERN

T-D9550

SCT

64234005

Patella

PATELLA

T-12730

SCT

816092008

Pelvis

PELVIS

SCT

62413002

Radius

RADIUS

T-12420

SCT

110535000

Radius and ulna

RADIUSULNA

T-12403

SCT

54735007

Sacrum

SSPINE

T-11AD0

SCT

16982005

Shoulder

SHOULDER

T-D2220

SCT

89546000

Skull

SKULL

T-11100

SCT

116010006

Stiffle

STIFLE

T-15728

SCT

108371006

Tarsus

TARSUS

T-12761

SCT

122495006

Thoracic spine

TSPINE

T-11502

SCT

1217256009

Thoraco-lumbar spine

TLSPINE

SCT

12611008

Tibia

TIBIA

T-12740

SCT

110536004

Tibia and fibula

TIBIAFIBULA

T-12701

SCT

62834003

Upper gastro-intestinal tract

UGITRACT

T-50110

SCT

23416004

Ulna

ULNA

T-12430

SCT

13648007

Urethra

URETHRA

T-75000

SCT

431938005

Urinary tract

URINARYTRACT

T-7000C

SCT

53036007

Wing

WING

T-D8040


Note

In prior versions of this table, different codes were used for some concepts; see PS3.16-2011.

Table L-3. Corresponding Codes And Terms for Small Animal Use

Coding Scheme Designator

Code Value

Code Meaning

Body Part Examined

SNOMED-RT ID (Retired)

FMA ID

Mouse Anatomy ID

NCIt ID

Uberon ID

UMLS Concept UniqueID

SCT

23451007

Adrenal gland

ADRENAL

T-B3000

9604

0000116

C12666

0002369

C0001625

SCT

70258002

Ankle joint

ANKLE

T-15750

35195

0000463

C32078

0001488

C0003087

SCT

15825003

Aorta

AORTA

T-42000

3734

0000062

C12669

0000947

C0003483

SCT

89837001

Bladder

BLADDER

T-74000

15900

0000380

C12414

0001255

C0005682

SCT

12738006

Brain

BRAIN

T-A0100

50801

0000168

C12439

0000955

C0006104

SCT

76752008

Breast

BREAST

T-04000

57983

0000145

C12367

0001911

C0929301

SCT

955009

Bronchus

BRONCHUS

T-26000

7409

0000436

C12683

0002185

C0006255

SCT

60819002

Buccal region of face

CHEEK

T-D1206

46476

0002475

C13070

0001567

C0007966

SCT

80144004

Calcaneus

CALCANEUS

T-12770

24496

0001348

C32250

0001450

C0006655

SCT

69105007

Carotid Artery

CAROTID

T-45010

0001925

C12687

0005396

C0007272

SCT

113305005

Cerebellum

CEREBELLUM

T-A6000

67944

0000198

C12445

0002037

C0007765

SCT

71252005

Cervix

CERVIX

T-83200

17740

0000392

C12311

0000002

C0007874

SCT

51299004

Clavicle

CLAVICLE

T-12310

13321

0001329

C12695

0001105

C0008913

SCT

64688005

Coccyx

COCCYX

T-11BF0

20229

0001420

C12696

0001095

C0009194

SCT

71854001

Colon

COLON

T-59300

14543

0000335

C12382

0001155

C0009368

SCT

28726007

Cornea

CORNEA

T-AA200

58238

0000266

C12342

0000964

C0010031

SCT

41801008

Coronary artery

CORONARYARTERY

T-43000

49893

0002453

C12843

0001621

C0205042

SCT

82680008

Digit

DIGIT

T-D0310

85518

0000690

C40186

0002544

C0582802

SCT

38848004

Duodenum

DUODENUM

T-58200

7206

0000338

C12263

0002114

C0013303

SCT

16953009

Elbow joint

ELBOW

T-15430

35289

0000451

C32497

0001490

C0013770

SCT

32849002

Esophagus

ESOPHAGUS

T-56000

7131

0000352

C12389

0001043

C0014876

SCT

66019005

Extremity

EXTREMITY

T-D0300

7182

0000007

C12429

0002101

C0015385

SCT

81745001

Eye

EYE

T-AA000

54448

0000261

C12401

0000019

C0015392

SCT

80243003

Eyelid

EYELID

T-AA810

54437

0000268

C12713

0001711

C0015426

SCT

89545001

Face

FACE

T-D1200

24728

0002473

C13071

0001456

C0015450

SCT

71341001

Femur

FEMUR

T-12710

9611

0001359

C12717

0000981

C0015811

SCT

87342007

Fibula

FIBULA

T-12750

24479

0001360

C12718

0001446

C0016068

SCT

7569003

Finger

FINGER

T-D8800

9666

0000041

C32608

0002389

C0016129

SCT

56459004

Foot

FOOT

T-D9700

9664

0000044

C32622

0002387

C0016504

SCT

55060009

Frontal sinus

FRONTALSINUS

T-22200

57417

0001793

C12277

0001760

C0016734

SCT

28231008

Gallbladder

GALLBLADDER

T-63000

7202

0000356

C12377

0002110

C0016976

SCT

85562004

Hand

HAND

T-D8700

9712

0000037

C32712

0002398

C0018563

SCT

69536005

Head

HEAD

T-D1100

7154

0000023

C12419

0000033

C0018670

SCT

774007

Head and Neck

HEADNECK

T-D1000

0000006

C12418

0007811

C0460004

SCT

80891009

Heart

HEART

T-32000

7088

0000072

C12727

0000948

C0018787

SCT

24136001

Hip joint

HIP

T-15710

35178

0000470

C32742

0001486

C0019558

SCT

85050009

Humerus

HUMERUS

T-12410

13303

0001356

C12731

0000976

C0020164

SCT

34516001

Ileum

ILEUM

T-58600

7208

0000339

C12387

0002116

C0020885

SCT

22356005

Ilium

ILIUM

T-12340

16589

0001336

C32765

0001273

C0020889

SCT

661005

Jaw region

JAW

T-D1213

54396

0001905

C48821

0001708

C0022359

SCT

21306003

Jejunum

JEJUNUM

T-58400

7207

0000340

C12388

0002115

C0022378

SCT

64033007

Kidney

KIDNEY

T-71000

7203

0000368

C12415

0002113

C0022646

SCT

10200004

Liver

LIVER

T-62000

7197

0000358

C12392

0002107

C0023884

SCT

30021000

Lower leg

LEG

T-D9400

24979

0000047

C32974

0000978

C1140621

SCT

39607008

Lung

LUNG

T-28000

7195

0000415

C12468

0002048

C0024109

SCT

91609006

Mandible

JAW

T-11180

52748

0001487

C12290

0001684

C0024687

SCT

70925003

Maxilla

MAXILLA

T-11170

9711

0001491

C26470

0002397

C0024947

SCT

30518006

Navicular of forefoot

FORENAVICULAR

T-12450

33311

0002555

C12854

0001427

C0223724

SCT

45048000

Neck

NECK

T-D1600

7155

0000024

C13063

0000974

C0027530

SCT

363654007

Orbital structure

ORBIT

T-D14AE

53074

0002482

C12347

0001697

C0029180

SCT

15497006

Ovary

OVARY

T-87000

7209

0000384

C12404

0000992

C0029939

SCT

15776009

Pancreas

PANCREAS

T-65000

7198

0000120

C12393

0001264

C0030274

SCT

45289007

Parotid gland

PAROTID

T-61100

59790

0001585

C12427

0001831

C0030580

SCT

64234005

Patella

PATELLA

T-12730

24485

0001374

C33282

0002446

C0030647

SCT

816092008

Pelvis

PELVIS

9578

0000030

C12767

0002355

SCT

18911002

Penis

PENIS

T-91000

9707

0000408

C12409

0000989

C0030851

SCT

54066008

Pharynx

PHARYNX

T-55000

46688

0000432

C12425

0001042

C0031354

SCT

62413002

Radius

RADIUS

T-12420

23463

0001357

C12777

0001423

C0034627

SCT

34402009

Rectum

RECTUM

T-59600

14544

0000336

C12390

0001052

C0034896

SCT

113197003

Rib

RIB

T-11300

7574

0000315

C12782

0002228

C0035561

SCT

79601000

Scapula

SCAPULA

T-12280

13394

0001330

C12783

0006849

C0036277

SCT

18619003

Sclera

SCLERA

T-AA110

58269

0000280

C12784

0001773

C0036410

SCT

20233005

Scrotum

SCROTUM

T-98000

18252

0000409

C12785

0001300

C0036471

SCT

16982005

Shoulder

SHOULDER

T-D2220

25202

0000038

C25203

0001467

C0037004

SCT

89546000

Skull

SKULL

T-11100

46565

0000316

C12789

0003128

C0037303

SCT

78961009

Spleen

SPLEEN

T-C3000

7196

0000141

C12432

0002106

C0037993

SCT

56873002

Sternum

STERNUM

T-11210

7485

0001331

C12793

0000975

C0038293

SCT

53620006

Temporomandibular joint

TMJ

T-15290

54832

0002899

C32888

0003700

C0039493

SCT

40689003

Testis

TESTIS

T-94000

7210

0000411

C12412

0000473

C0039597

SCT

68367000

Thigh

THIGH

T-D9100

24967

0000052

C33763

0000376

C0039866

SCT

76505004

Thumb

THUMB

T-D8810

24938

0000454

C52834

0001463

C0040067

SCT

9875009

Thymus

THYMUS

T-C8000

9607

0000142

C12433

0002370

C0040113

SCT

69748006

Thyroid

THYROID

T-B6000

9603

0000129

C12400

0002046

C0040132

SCT

12611008

Tibia

TIBIA

T-12740

24476

0001361

C12800

0000979

C0040184

SCT

29707007

Toe

TOE

T-D9800

25046

0000048

C33788

0001466

C0040357

SCT

21974007

Tongue

TONGUE

T-53000

54640

0000347

C12422

0001723

C0040408

SCT

23416004

Ulna

ULNA

T-12430

23466

0001358

C12809

0001424

C0041600

SCT

40983000

Upper arm

ARM

T-D8200

24890

0000033

C32141

0001460

C0446516

SCT

87953007

Ureter

URETER

T-73000

9704

0000378

C12416

0000056

C0041951

SCT

13648007

Urethra

URETHRA

T-75000

19667

0000379

C12417

0000057

C0041967

SCT

35039007

Uterus

UTERUS

T-83000

17558

0000389

C12405

0000995

C0042149

SCT

76784001

Vagina

VAGINA

T-82000

19949

0000394

C12407

0000996

C0042232

SCT

45292006

Vulva

VULVA

T-81000

20462

0000395

C12408

0000997

C0042993


Note

Since the Adult Mouse Anatomy Ontology is not in the UMLS, the mapping of Mouse Anatomy codes described here is an extract of a mapping to the NCI Thesaurus described in Hayamizu TF, de Coronado S, Fragoso G, Sioutos N, Kadin JA, Ringwald M. The mouse-human anatomy ontology mapping project. Database: The Journal of Biological Databases and Curation 2012;2012:bar066. doi:10.1093/database/bar066. http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3308156/. The mapping files used can be found at ftp://ftp.informatics.jax.org/pub/reports/ma2ncit.obo.

The NCI Thesaurus codes were then used to look up corresponding concepts in UMLS, from which SNOMED and FMA codes were extracted automatically (and various conflicts and ambiguities resolved manually). The same correspondence to existing Body Part Examined values is used as in other tables in this Annex.

Another mapping project using the FMA as a reference ontology was not used, since the files were not available. See Zhang S, Bodenreider O. Alignment of Multiple Ontologies of Anatomy: Deriving Indirect Mappings from Direct Mappings to a Reference. AMIA Annual Symposium Proceedings 2005;2005:864-868 http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1560629/.

Table L-4. Correspondence between Animal-specific and Generic NCI Thesaurus Codes

Code Meaning

Generic NCIt ID

Generic UMLS Concept UniqueID

Mouse-specific NCIt ID

Mouse-specific UMLS Concept UniqueID

Rat-specific NCIt ID

Rat-specific UMLS Concept UniqueID

Adrenal gland

C12666

C0001625

C22635

C1515888

C60540

C1882555

Ankle joint

C32078

C0003087

Aorta

C12669

C0003483

C23600

C60541

C1882561

Bladder

C12414

C0005682

C22729

C1511191

C60634

C1882899

Brain

C12439

C0006104

C22606

C1521713

C60544

C1882598

Breast

C12367

C0929301

C22549

C1512980

C60585

C1882771

Bronchus

C12683

C0006255

C24050

C1518036

C60546

C1882603

Buccal region of face

C13070

C0007966

C23972

Calcaneus

C32250

C0006655

Carotid Artery

C12687

C0007272

C23618

Cerebellum

C12445

C0007765

C22609

C1522278

C60550

C1882617

Cervix

C12311

C0007874

C60635

C1882903

Clavicle

C12695

C0008913

C23626

Coccyx

C12696

C0009194

Colon

C12382

C0009368

C22528

C1522281

C60554

C1882628

Cornea

C12342

C0010031

C22717

C2700413

Coronary artery

C12843

C0205042

C23773

Digit

C40186

C0582802

Duodenum

C12263

C0013303

C22523

C1522711

C60558

C1882648

Elbow joint

C32497

C0013770

Esophagus

C12389

C0014876

C22509

C1516967

C60563

C1882662

Extremity

C12429

C0015385

C23363

Eye

C12401

C0015392

C22711

C1517081

C60565

C1882665

Eyelid

C12713

C0015426

C23644

C60566

C1882666

Face

C13071

C0015450

C23973

Femur

C12717

C0015811

C23648

C60567

C1882669

Fibula

C12718

C0016068

C23649

Finger

C32608

C0016129

Foot

C32622

C0016504

Frontal sinus

C12277

C0016734

C23210

Gallbladder

C12377

C0016976

C23312

Hand

C32712

C0018563

Head

C12419

C0018670

C23353

Head and Neck

C12418

C0460004

C23352

Heart

C12727

C0018787

C22498

C1512359

C60571

C1882687

Hip joint

C32742

C0019558

Humerus

C12731

C0020164

C23662

Ileum

C12387

C0020885

C22525

C1522516

C60573

C1882700

Ilium

C32765

C0020889

Jaw region

C48821

C0022359

C22683

C1511239

Jejunum

C12388

C0022378

C22524

C1522714

C60575

C1882710

Kidney

C12415

C0022646

C22730

C1517673

C60577

C1882714

Liver

C12392

C0023884

C22515

C1517914

C60581

C1882726

Lower leg

C32974

C1140621

Lung

C12468

C0024109

C22600

C1518039

C60582

C1882727

Mandible

C12290

C0024687

C23223

Maxilla

C26470

C0024947

Navicular of forefoot

C12854

C0223724

Neck

C13063

C0027530

C23965

Orbital structure

C12347

C0029180

C23282

C60594

C1882803

Ovary

C12404

C0029939

C22656

C1518753

C60595

C1882808

Pancreas

C12393

C0030274

C24044

C1518865

C60597

C1882810

Parotid gland

C12427

C0030580

C22504

C1527051

C60600

C1882814

Patella

C33282

C0030647

Pelvis

C12767

C23698

Penis

C12409

C0030851

C22172

C1518951

Pharynx

C12425

C0031354

C22507

C1519041

Radius

C12777

C0034627

C23708

Rectum

C12390

C0034896

C22532

C1522513

C60609

C1882833

Rib

C12782

C0035561

C23713

Scapula

C12783

C0036277

C23714

Sclera

C12784

C0036410

C23715

Scrotum

C12785

C0036471

C22176

C1519206

Shoulder

C25203

C0037004

Skull

C12789

C0037303

C22684

C1522418

Spleen

C12432

C0037993

C22556

C1519474

C60621

C1882867

Sternum

C12793

C0038293

C23724

C60622

C1882873

Temporomandibular joint

C32888

C0039493

Testis

C12412

C0039597

C22178

C1515315

C60625

C1882878

Thigh

C33763

C0039866

Thumb

C52834

C0040067

Thymus

C12433

C0040113

C22553

C1515438

C60627

C1882880

Thyroid

C12400

C0040132

C22650

C1522142

C60628

C1882881

Tibia

C12800

C0040184

C23731

Toe

C33788

C0040357

Tongue

C12422

C0040408

C22508

C1519545

C60629

C1882882

Ulna

C12809

C0041600

C23740

Upper arm

C32141

C0446516

Ureter

C12416

C0041951

C22738

C1519822

C60632

C1882897

Urethra

C12417

C0041967

C22739

C1519824

C60633

C1882898

Uterus

C12405

C0042149

C22671

C1519876

C60636

C1882904

Vagina

C12407

C0042232

C22676

C1519910

C60637

C1882906

Vulva

C12408

C0042993

C22677

C1520067


Note

For the mouse, NCIt contains some duplicate anatomical concepts, including those which have been marked inactive and appear to have been replaced with improved codes for the "Mouse Models of Human Cancers Consortium" (MMHCC). Whenever duplicates were found, the MMHCC concept has been used in this table.

This table was produced by searching NCIt for all concepts that had "mouse" or "rat" in their concept name or synonyms, and then using that synonym with the word "mouse" or "rat" removed, to match against generic concept names.

The NCI Thesaurus codes were then used to look up corresponding concepts in UMLS, though not all of the concepts are included in UMLS yet (especially the MMHCC concepts).

Table L-5. Pairedness of Anatomic Concepts

SNOMED Code Value

Code Meaning

Paired Structure

77012006

Amniotic fluid

N

818981001

Abdomen

N

818982008

Abdomen and Pelvis

N

7832008

Abdominal aorta

N

85856004

Acromioclavicular joint

Y

23451007

Adrenal gland

Y

70258002

Ankle joint

Y

128585006

Anomalous pulmonary vein

N

128553008

Antecubital vein

Y

194996006

Anterior cardiac vein

N

60176003

Anterior cerebral artery

Y

8012006

Anterior communicating artery

N

17388009

Anterior spinal artery

N

68053000

Anterior tibial artery

Y

110612005

Anus, rectum and sigmoid colon

N

15825003

Aorta

N

57034009

Aortic arch

N

128551005

Aortic fistula

N

128564006

Apex of left ventricle

N

86598002

Apex of Lung

Y

128565007

Apex of right ventricle

N

66754008

Appendix

N

51114001

Artery

Y

54247002

Ascending aorta

N

9040008

Ascending colon

N

59652004

Atrium

Y

91470000

Axilla

Y

67937003

Axillary Artery

Y

68705008

Axillary vein

Y

72107004

Azygos vein

N

77568009

Back

N

128981007

Baffle

N

59011009

Basilar artery

N

28273000

Bile duct

N

34707002

Biliary tract

N

89837001

Bladder

N

110837003

Bladder and urethra

N

91830000

Body conduit

N

128548003

Boyd's perforating vein

Y

17137000

Brachial artery

Y

20115005

Brachial vein

Y

12738006

Brain

N

76752008

Breast

Y

34411009

Broad ligament

N

955009

Bronchus

Y

60819002

Buccal region of face

N

46862004

Buttock

Y

80144004

Calcaneus

Y

53840002

Calf of leg

Y

2334006

Calyx

N

69105007

Carotid Artery

Y

21479005

Carotid Bulb

Y

57850000

Celiac artery

N

20699002

Cephalic vein

Y

113305005

Cerebellum

Y

88556005

Cerebral artery

Y

372073000

Cerebral hemisphere

Y

122494005

Cervical spine

N

1217257000

Cervico-thoracic spine

N

71252005

Cervix

N

60819002

Cheek

Y

816094009

Chest

N

416775004

Chest, Abdomen and Pelvis

N

416550000

Chest and Abdomen

N

80621003

Choroid Plexus

Y

11279006

Circle of Willis

N

51299004

Clavicle

Y

64688005

Coccyx

N

71854001

Colon

N

253276007

Common atrium

N

79741001

Common bile duct

N

32062004

Common carotid artery

Y

181347005

Common femoral artery

Y

397363009

Common femoral vein

Y

73634005

Common iliac artery

Y

46027005

Common iliac vein

Y

45503006

Common ventricle

N

128555001

Congenital coronary artery fistula to left atrium

N

128556000

Congenital coronary artery fistula to left ventricle

N

128557009

Congenital coronary artery fistula to right atrium

N

128558004

Congenital coronary artery fistula to right ventricle

N

111289009

Congenital pulmonary arteriovenous fistula

N

28726007

Cornea

Y

41801008

Coronary artery

N

90219004

Coronary sinus

N

32672002

Descending aorta

N

32622004

Descending colon

N

128554002

Dodd's perforating vein

Y

38848004

Duodenum

N

117590005

Ear

Y

16953009

Elbow joint

Y

51114001

Endo-arterial

N

80891009

Endo-cardiac

N

32849002

Endo-esophageal

N

2739003

Endometrium

N

53342003

Endo-nasal

N

18962004

Endo-nasopharyngeal

N

34402009

Endo-rectal

N

64033007

Endo-renal

N

87953007

Endo-ureteric

N

13648007

Endo-urethral

N

76784001

Endo-vaginal

N

59820001

Endo-vascular

N

29092000

Endo-venous

N

48367006

Endo-vesical

N

38266002

Entire body

N

87644002

Epididymis

Y

27947004

Epigastric region

N

32849002

Esophagus

N

110861005

Esophagus, stomach and duodenum

N

84301002

External auditory canal

Y

22286001

External carotid artery

Y

113269004

External iliac artery

Y

63507001

External iliac vein

Y

71585003

External jugular vein

Y

66019005

Extremity

Y

81745001

Eye

Y

80243003

Eyelid

Y

89545001

Face

N

23074001

Facial artery

Y

91397008

Facial bones

N

7657000

Femoral artery

Y

83419000

Femoral vein

Y

71341001

Femur

Y

7569003

Finger

Y

58602004

Flank

N

79361005

Fontanel of skull

N

56459004

Foot

Y

14975008

Forearm

Y

35918002

Fourth ventricle

N

28231008

Gallbladder

N

110568007

Gastric vein

Y

128559007

Genicular artery

Y

300571009

Gestational sac

N

46862004

Gluteal region

Y

5928000

Great cardiac vein

N

60734001

Great saphenous vein

Y

85562004

Hand

Y

69536005

Head

N

774007

Head and Neck

N

80891009

Heart

N

76015000

Hepatic artery

Y

8993003

Hepatic vein

Y

24136001

Hip joint

Y

85050009

Humerus

Y

128560002

Hunterian perforating vein

Y

11708003

Hypogastric region

N

81502006

Hypopharynx

N

34516001

Ileum

N

299716001

Iliac and/or femoral artery

Y

10293006

Iliac artery

Y

244411005

Iliac vein

Y

22356005

Ilium

Y

195416006

Inferior cardiac vein

N

51249003

Inferior left pulmonary vein

N

33795007

Inferior mesenteric artery

N

113273001

Inferior right pulmonary vein

N

64131007

Inferior vena cava

N

26893007

Inguinal region

Y

12691009

Innominate artery

N

8887007

Innominate vein

Y

361078006

Internal Auditory Canal

Y

86117002

Internal carotid artery

Y

90024005

Internal iliac artery

Y

12123001

Internal jugular vein

Y

69327007

Internal mammary artery

Y

818987002

Intra-abdominopelvic

N

131183008

Intra-articular

N

1101003

Intracranial

N

32849002

Intra-esophageal

N

816989007

Intra-pelvic

N

816094009

Intra-thoracic

N

661005

Jaw region

N

21306003

Jejunum

N

39352004

Joint

Y

128563000

Juxtaposed atrial appendage

N

64033007

Kidney

N

72696002

Knee

Y

59749000

Lacrimal artery

Y

128979005

Lacrimal artery of right eye

N

14742008

Large intestine

N

4596009

Larynx

N

66720007

Lateral Ventricle

Y

82471001

Left atrium

N

33626005

Left auricular appendage

N

9775002

Left carotid sinus

N

113270003

Left femoral artery

N

273202007

Left hepatic vein

N

133945003

Left hypochondriac region

N

85119005

Left inguinal region

N

68505006

Left lower quadrant of abdomen

N

1017210004

Left lumbar region

N

70253006

Left portal vein

N

50408007

Left pulmonary artery

N

86367003

Left upper quadrant of abdomen

N

87878005

Left ventricle

N

70238003

Left ventricle inflow

N

13418002

Left ventricle outflow tract

N

113264009

Lingual artery

Y

10200004

Liver

N

19100000

Lower inner quadrant of breast

Y

30021000

Lower leg

Y

33564002

Lower outer quadrant of breast

Y

34635009

Lumbar artery

Y

52612000

Lumbar region

Y

122496007

Lumbar spine

N

1217253001

Lumbo-sacral spine

N

91747007

Lumen of blood vessel

N

39607008

Lung

Y

91609006

Mandible

N

59066005

Mastoid bone

Y

70925003

Maxilla

Y

72410000

Mediastinum

N

86570000

Mesenteric artery

N

128583004

Mesenteric vein

N

17232002

Middle cerebral artery

Y

273099000

Middle hepatic vein

N

243977002

Morisons pouch

N

123851003

Mouth

N

74386004

Nasal bone

Y

360955006

Nasopharynx

N

45048000

Neck

N

416319003

Neck, Chest, Abdomen and Pelvis

N

416152001

Neck, Chest and Abdomen

N

417437006

Neck and Chest

N

45206002

Nose

N

31145008

Occipital artery

Y

32114007

Occipital vein

Y

113346000

Omental bursa

N

27398004

Omentum

N

53549008

Ophthalmic artery

Y

55024004

Optic canal

Y

363654007

Orbital structure

Y

15497006

Ovary

Y

15776009

Pancreas

N

69930009

Pancreatic duct

N

110621006

Pancreatic duct and bile duct systems

N

2095001

Paranasal sinus

Y

91691001

Parasternal

N

111002

Parathyroid

Y

45289007

Parotid gland

Y

64234005

Patella

Y

83330001

Patent ductus arteriosus

N

816092008

Pelvis

N

1231522001

Pelvis and lower extremities

N

282044005

Penile artery

Y

18911002

Penis

N

38864007

Perineum

N

8821006

Peroneal artery

Y

54066008

Pharynx

N

312535008

Pharynx and larynx

N

78067005

Placenta

N

43899006

Popliteal artery

Y

32361000

Popliteal fossa

Y

56849005

Popliteal vein

Y

32764006

Portal vein

N

70382005

Posterior cerebral artery

Y

43119007

Posterior communicating artery

Y

128569001

Posterior medial tributary

N

13363002

Posterior tibial artery

Y

14944004

Primitive aorta

N

91707000

Primitive pulmonary artery

N

31677005

Profunda femoris artery

Y

23438002

Profunda femoris vein

Y

41216001

Prostate

N

81040000

Pulmonary artery

Y

128584005

Pulmonary artery conduit

N

128586007

Pulmonary chamber of cor triatriatum

N

122972007

Pulmonary vein

Y

128566008

Pulmonary vein confluence

N

128567004

Pulmonary venous atrium

N

45631007

Radial artery

Y

62413002

Radius

Y

110535000

Radius and ulna

Y

53843000

Rectouterine pouch

N

34402009

Rectum

N

2841007

Renal artery

Y

25990002

Renal pelvis

Y

56400007

Renal vein

Y

82849001

Retroperitoneum

N

113197003

Rib

Y

73829009

Right atrium

N

68300000

Right auricular appendage

N

69833005

Right femoral artery

N

272998002

Right hepatic vein

N

133946002

Right hypochondriac region

N

37117007

Right inguinal region

N

48544008

Right lower quadrant of abdomen

N

1017211000

Right lumbar region

N

73931004

Right portal vein

N

78480002

Right pulmonary artery

N

50519007

Right upper quadrant of abdomen

N

53085002

Right ventricle

N

8017000

Right ventricle inflow

N

44627009

Right ventricle outflow tract

N

39723000

Sacroiliac joint

Y

54735007

Sacrum

N

128587003

Saphenofemoral junction

Y

362072009

Saphenous vein

Y

41695006

Scalp

N

79601000

Scapula

Y

18619003

Sclera

Y

20233005

Scrotum

Y

42575006

Sella turcica

N

64739004

Seminal vesicle

N

58742003

Sesamoid bones of foot

Y

16982005

Shoulder

Y

60184004

Sigmoid colon

N

89546000

Skull

N

30315005

Small intestine

N

2748008

Spinal cord

N

421060004

Spine

N

78961009

Spleen

N

22083002

Splenic artery

N

35819009

Splenic vein

N

7844006

Sternoclavicular joint

Y

56873002

Sternum

N

69695003

Stomach

N

36765005

Subclavian artery

Y

9454009

Subclavian vein

Y

19695001

Subcostal

Y

5713008

Submandibular area

Y

54019009

Submandibular gland

Y

170887008

Submental

N

5076001

Subxiphoid

N

181349008

Superficial femoral artery

Y

397364003

Superficial femoral vein

Y

15672000

Superficial temporal artery

Y

43863001

Superior left pulmonary vein

N

42258001

Superior mesenteric artery

N

8629005

Superior right pulmonary vein

N

72021004

Superior thyroid artery

Y

48345005

Superior vena cava

N

77621008

Supraclavicular region of neck

Y

11708003

Suprapubic region

N

26493002

Suprasternal notch

N

128589000

Systemic collateral artery to lung

N

128568009

Systemic venous atrium

N

27949001

Tarsal joint

Y

53620006

Temporomandibular joint

Y

40689003

Testis

Y

42695009

Thalamus

Y

68367000

Thigh

Y

49841001

Third ventricle

N

113262008

Thoracic aorta

N

122495006

Thoracic spine

N

1217256009

Thoraco-lumbar spine

N

816094009

Thorax

N

76505004

Thumb

Y

9875009

Thymus

N

69748006

Thyroid

N

12611008

Tibia

Y

110536004

Tibia and fibula

Y

29707007

Toe

Y

21974007

Tongue

N

44567001

Trachea

N

110726009

Trachea and bronchus

N

485005

Transverse colon

N

61959006

Truncus arteriosus communis

N

57850000

Truncus coeliacus

N

23416004

Ulna

Y

44984001

Ulnar artery

Y

50536004

Umbilical artery

N

90290004

Umbilical region

N

284639000

Umbilical vein

N

40983000

Upper arm

Y

77831004

Upper inner quadrant of breast

Y

76365002

Upper outer quadrant of breast

Y

431491007

Upper urinary tract

N

87953007

Ureter

Y

13648007

Urethra

N

35039007

Uterus

N

110639002

Uterus and fallopian tubes

N

76784001

Vagina

N

118375008

Vascular graft

N

29092000

Vein

Y

34340008

Venous network

N

21814001

Ventricle

Y

85234005

Vertebral artery

Y

110517009

Vertebral column and cranium

N

45292006

Vulva

N

74670003

Wrist joint

Y

13881006

Zygoma

Y


DICOM PS3.16 2024c - Content Mapping Resource