This message describes the event of a patient record being created, modified, accessed, or deleted.
Note
There are several types of patient records managed by both DICOM and non-DICOM system. DICOM applications often manipulate patient records managed by a variety of systems, and thus may be obligated by site security policies to record such events in the audit logs. This audit event can be used to record the access or manipulation of patient records where specific DICOM SOP Instances are not involved.
Table A.5.3.14-1. Audit Message for Patient Record
|
Real World Entities
|
Field Name
|
Opt.
|
Value Constraints
|
|
Event
|
EventID
|
M
|
EV (110110, DCM, "Patient Record")
|
|
EventActionCode
|
M
|
Enumerated value:
C = create
R = read
U = update
D = delete
|
|
EventDateTime
|
M
|
not specialized
|
|
EventOutcomeIndicator
|
M
|
not specialized
|
|
EventTypeCode
|
U
|
not specialized
|
|
User (1..2)
|
UserID
|
M
|
The identity of the person or process manipulating the data. If both are known, then two active participants shall be included (both the person and the process).
|
|
AlternativeUserID
|
U
|
not specialized
|
|
UserName
|
U
|
not specialized
|
|
UserIsRequestor
|
U
|
not specialized
|
|
RoleIDCode
|
U
|
not specialized
|
|
NetworkAccessPointTypeCode
|
U
|
not specialized
|
|
NetworkAccessPointID
|
U
|
not specialized
|
|
Patient (1)
|
ParticipantObjectTypeCode
|
M
|
Shall be: 1 = Person
|
|
ParticipantObjectTypeCodeRole
|
M
|
Shall be: 1 = Patient)
|
|
ParticipantObjectDataLifeCycle
|
U
|
not specialized
|
|
ParticipantObjectIDTypeCode
|
M
|
Shall be: 2 = Patient Number
|
|
ParticipantObjectSensitivity
|
U
|
not specialized
|
|
ParticipantObjectID
|
M
|
The patient ID
|
|
ParticipantObjectName
|
U
|
The patient name
|
|
ParticipantObjectQuery
|
U
|
not specialized
|
|
ParticipantObjectDetail
|
U
|
not specialized
|
|
ParticipantObjectDescription
|
U
|
not further specialized
|