| DICOM PS3.4 2024c - Service Class Specifications |
|---|
The DICOM AEs that claim conformance to this SOP Class as an SCU shall invoke the N-ACTION request. The DICOM AEs that claim conformance to this SOP Class as an SCP shall support the N-ACTION request.
This operation allows an SCU to submit a Medication Administration Record log item or entry, providing information about a specific real-world act of Substance Administration that is the purview of the SCU. This operation shall be invoked through the DIMSE N-ACTION Service.
The Action Information Attributes are defined by the Substance Administration Log Module specified in PS3.3. The DICOM AEs that claim conformance to this SOP Class as an SCU and/or an SCP shall support the Action Type and Action Information Attributes in the N-ACTION-RQ as specified in Table P.3-2.
Table P.3-2. Substance Administration Logging N-ACTION Information
|
(Required if an extended or replacement character set is used) |
||||
|
Either or both Patient ID and Admission ID shall be supplied by the SCU; the SCP shall support the Attribute if supplied |
||||
|
Either or both Patient ID and Admission ID shall be supplied by the SCU; the SCP shall support the Attribute if supplied |
||||
|
Either or both Product Package Identifier and Product Name shall be supplied by the SCU; the SCP shall support the Attribute if supplied |
||||
|
Either or both Product Package Identifier and Product Name shall be supplied by the SCU; the SCP shall support the Attribute if supplied |
||||
|
>Include Table 8-1a “Enhanced SCU/SCP Coded Entry Macro with SCU Support, Matching Key Support and Mandatory Meaning” |
||||
|
>All Attributes of the Substance Administration Parameter Sequence |
||||
|
>>Include Table 8-1a “Enhanced SCU/SCP Coded Entry Macro with SCU Support, Matching Key Support and Mandatory Meaning” |
||||
| DICOM PS3.4 2024c - Service Class Specifications |
|---|