| DICOM PS3.4 2024c - Service Class Specifications |
|---|
The N-SET may be used to update the last created instance of the Basic Film Box SOP Class.
The Attributes that may be updated are shown in Table H.4-7.
The meaning of the Usage SCU/SCP is described in Section H.2.4.
The status values that are specific for this SOP Class are defined in Section H.4.2.2.1.2.
The SCU uses the N-SET to request the SCP to update a Basic Film Box SOP Instance. The SCU shall only specify the SOP Instance UID of the last created Basic Film Box SOP Instance in the N-SET request primitive, and shall specify the list of Attributes for which the Attribute Values are to be set.
The SCP shall set new values for the specified Attributes of the specified SOP Instance.
The SCP shall return the Status Code of the requested SOP Instance update. The meaning of success, warning, and Failure Status Codes is defined in Section H.2.5.
| DICOM PS3.4 2024c - Service Class Specifications |
|---|