DICOM PS3.3 2024c - Information Object Definitions

C.8.35.2 Confocal Microscopy Tiled Pyramidal Image Module

Table C.8.35.2-1specifies the Attributes that describe a confocal microscopy tiled pyramidal image.

Table C.8.35.2-1. Confocal Microscopy Tiled Pyramidal Image Module Attributes

Attribute Name

Tag

Type

Attribute Description

Imaged Volume Width

(0048,0001)

1

Width of total imaged volume (distance in the direction of rows in each frame) in mm.

Imaged Volume Height

(0048,0002)

1

Height of total imaged volume (distance in the direction of columns in each frame) in mm.

Imaged Volume Depth

(0048,0003)

1

Depth of total imaged volume (distance in the z direction of focal planes) in mm.

Volumetric Properties

(0008,9206)

1

Indication if geometric manipulations are possible with frames in the SOP Instance. See Section C.8.16.2.1.2.

Enumerated Values:

VOLUME

Image contains pixels that represent the volume specified for the image, and may be geometrically manipulated


DICOM PS3.3 2024c - Information Object Definitions