| DICOM PS3.3 2024c - Information Object Definitions |
|---|
C.8.12.13-1 specifies the Attributes that describe dermoscopic images.
Table C.8.12.13-1. Dermoscopic Image Module Attributes
|
Indicates whether or not the image contains sufficiently recognizable visual features to allow the image or a reconstruction from a set of images to identify the Patient. The value of Recognizable Visual Features (0028,0302) shall be YES if the image contains the patient's fingerprints. |
|||
|
Whether or not the image was acquired with the dermoscope in direct contact with the skin. |
|||
|
The interface between the dermoscope and the skin surface for images acquired with contact dermoscopy. |
|||
|
Optical magnification factor when the image was acquired. Optical magnification is achieved using the optics of the dermoscope. The number indicates the magnification factor in times (X). The size of an object (e.g., a skin lesion) would appear on the sensor n times larger than the object when imaged with a dermoscope using n X optical magnification. |
|||
|
Indicates whether this image is a partial view, that is a subset of a single view of a skin lesion. If this Attribute is absent, then the image may or may not be a partial view. |
|||
|
Free text description of the portion of the skin lesion captured in a partial view image. |
|||
|
A text label used for tracking a finding or feature, potentially across multiple reporting objects, over time. This label shall be unique within the domain in which it is used. Required if Tracking UID (0062,0021) is present. NoteThis Attribute allows linkage to Content Items in SR instances with observation context (112039, DCM, "Tracking Identifier") having the same value. |
|||
|
A unique identifier used for tracking a finding or feature, potentially across multiple reporting objects, over time. Required if Tracking ID (0062,0020) is present. NoteThis Attribute allows linkage to Content Items in SR instances with observation context (112040, DCM, "Tracking Unique Identifier") having the same value. |
| DICOM PS3.3 2024c - Information Object Definitions |
|---|