Table C.38.3-1 specifies the Attributes of the Inventory Creation Module, which are contained in an Inventory Creation Request/Response.
Table C.38.3-1. Inventory Creation Module Attributes
|
Include Table C.38.2-1 “Scope of Inventory Macro Attributes” |
Key Attribute values for the Studies to be included in the Inventory. |
|
|
Unique identifier of a transaction initiating the production of an Inventory. |
||
|
Processing status for this transaction. (See Section KK.2.1.1 “Inventory Production States” in PS3.4). |
||
|
Explanation or further detail of Transaction Status (0008,0417). |
||
|
The date and time until which the Inventory SOP Instance is expected to be available. See Section C.38.3.1.3. |
||
|
Information Entity level for records to be included in Inventory. |
||
|
SOP Instance UID of the produced Inventory SOP Instance at the root of the tree of incorporated Inventory SOP Instances (see Section C.38.3.1.1). |
||
|
AE Title from which the Inventory SOP Instance may be retrieved through Inventory MOVE or Inventory GET SOP Classes (see Annex JJ “Inventory Query/Retrieve Service Class” in PS3.4). |
||
|
Base URI of the origin server from which the Inventory SOP Instance may be retrieved through the Non-Patient Instance Service (see Section 12 “Non-Patient Instance Service and Resources” in PS3.18). |
||
|
Base URI for accessing the Inventory SOP Instance through a non-DICOM protocol. See Section C.38.3.1.2. |
||
|
Include Table C.38.2-2 “Stored File Access Macro Attributes” |
See Section C.38.3.1.2. |
|
|
Number of Studies found and processed into Inventory SOP Instances (as of time of message) that match Scope of Inventory. |
||
|
Requested interval, in minutes, between Inventory Status notifications. Value shall be greater than 0. |
||
|
Whether produced Inventory SOP Instances should be retained when Inventory production is canceled. |
||
The content of an Inventory may be divided into more than one Inventory SOP Instance, organized as a tree of SOP Instances with one SOP Instance as the root (see Section C.38.1.1.5 and Section YYYY.3.3 “Inventory Instance Tree” in PS3.17). Only the root Inventory SOP Instance is identified in this data set in the Referenced SOP Instance UID (0008,1155); that SOP Instance includes the entire tree of references to SOP Instances comprising the Inventory.
If the produced Inventory SOP Instance is stored in the DICOM File Format (see Section 7 “DICOM File Format” in PS3.10) and is accessible through a non-DICOM protocol (see Annex P), the File Access URI (0008,0409) contains an [RFC3986] URI for non-DICOM protocol access to the Inventory SOP Instance. File Access URI (0008,0409) may be a relative path reference URI, which is merged with the Stored Instance Base URI (0008,0407) in accordance with Section P.2.1.
File Access URI (0008,0409) may reference a container file that includes the Inventory SOP Instance (see notes in Section C.38.2.3.1.2).
A data management system may manage the storage lifecycle of the Inventory SOP Instances (e.g., by deleting older Inventory objects after a predetermined time). If there is a scheduled or expected time for SOP Inventory Instance deletion, it may be identified in the Expiration DateTime (0008,0416) Attribute. This is not a guaranteed expiration time; the SOP Instances may become unavailable at an earlier or later time. This Expiration DateTime (0008,0416) applies to all available access methods (both DICOM and non-DICOM protocols).
See Section YYYY.7.5 “Inventory Lifecycle Management” in PS3.17 for further discussion.