| DICOM PS3.3 2024c - Information Object Definitions |
|---|
The following Sections specify Modules used for Unified Procedure Steps.
Table C.30.1-1 specifies the Attributes of the Unified Procedure Step Progress Information Module, which describe the progress of a Unified Procedure Step (UPS).
Table C.30.1-1. Unified Procedure Step Progress Information Module Attributes
|
See PS3.4 for details on Unified Procedure Step states. |
||
|
A numerical indicator of progress expressed as percentage complete. |
||
|
Additional procedure-specific progress information provided by the performing device while the current Procedure Step is being executed. |
||
|
No Baseline CIDs are defined for Concept Name Code Sequence or Concept Code Sequence. |
||
|
Sequence that specifies modifiers for a Procedure Step Progress Parameter. |
||
|
>>>Include Table 10-2 “Content Item Macro Attributes” |
No Baseline CIDs are defined for Concept Name Code Sequence or Concept Code Sequence. |
|
|
Contact Information to communicate with performers of the Procedure Step. |
||
|
URI to communicate with performer of the procedure in progress. Any URI (telephone number, URL, etc.) is permitted. |
||
|
Name of the person, department or organization to contact for more information about the performance of the Procedure Step. |
||
|
A textual description of the reason a procedure step was discontinued. |
||
| DICOM PS3.3 2024c - Information Object Definitions |
|---|