| DICOM PS3.3 2024c - Information Object Definitions |
|---|
Table A.35.4-1 specifies the Modules of the Key Object Selection Document IOD.
The Specimen Identification Module (Retired) was previously included in this IOD but has been retired. See PS3.3-2008.
Value Type (0040,A040) in Content Sequence (0040,A730) of the SR Document Content Module is constrained to the following Enumerated Values (see Table C.17.3-7 for Value Type definitions):
Relationships between Content Items in the content of this IOD shall be conveyed in the by-value mode. See Table C.17.3-8 for Relationship Type definitions.
Relationships by-reference are forbidden. Therefore, Referenced Content Item Identifier (0040,DB73) is not present in any of the Content Items within the SR Document Content Module.
Table A.35.4-2 specifies the relationship constraints of this IOD.
The document shall be constructed from TID 2010 “Key Object Selection” invoked at the root node.
| DICOM PS3.3 2024c - Information Object Definitions |
|---|