DICOM PS3.2 2024c - Conformance

N.9.3.2 A.A.3.2 <Image IOD 2> Functional Group Macro

The tables below list functional group macros and Attributes for <Image IOD 2>:

[For enhanced objects provide the list of IOD specific shared Functional Group Macros and per-frame Functional Group Macros. Create one table for each supported Functional Group Macro using the structure defined below.]

Table N.9-32. CT Frame Type Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

CT Image Frame Type Sequence

(0018,9329)


Table N.9-33. CT Acquisition Type Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

CT Acquisition Type Sequence

(0018,9301)


Table N.9-34. CT Acquisition Details Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

CT Acquisition Details Sequence

(0018,9304)


Table N.9-35. CT Table Dynamics Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

CT Table Dynamics Sequence

(0018,9308)


Table N.9-36. CT Position Functional Group Macro for < Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

CT Position Sequence

(0018,9326)


Table N.9-37. CT Geometry Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

CT Geometry Sequence

(0018,9312)


Table N.9-38. CT Reconstruction Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

CT Reconstruction Sequence

(0018,9314)


Table N.9-39. CT Exposure Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

CT Exposure Sequence

(0018,9321)


Table N.9-40. CT X-Ray Details Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

CT X-Ray Details Sequence

(0018,9325)


Table N.9-41. CT Pixel Value Transformation Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

Pixel Value Transformation Sequence

(0028,9145)


Table N.9-42. CT Additional X-Ray Source Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

CT Additional X-Ray Source Sequence

(0018,9360)


Table N.9-43. CT Multi-energy CT Characteristics Functional Group Macro for <Image IOD 2>

Attribute Name

Tag

Source

Presence of Attribute

Presence of Value

Value

Conditions

Comments

Multi-energy CT Processing Sequence

(0018,9363)


DICOM PS3.2 2024c - Conformance