N.7.3.2.8 Print Management Service
N.7.3.2.8.1 SCU of the Basic Film Session SOP Class
N.7.3.2.8.1.1 SCU of the Basic Film Session SOP Class - N-CREATE
Table N.7-52 lists the Status Codes that the SCU of the Basic Film Session SOP Class supports for the N-CREATE message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-52. Status Codes for N-CREATE of the Basic Film Session SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Memory allocation not supported
|
B600
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.1.2 SCU of the Basic Film Session SOP Class - N-SET
Table N.7-53 lists the Status Codes that the SCU of the Basic Film Session SOP Class supports for the N-SET message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-53. Status Codes for N-SET of the Basic Film Session SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Memory allocation not supported
|
B600
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
No such SOP Instance
|
0112
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.1.3 SCU of the Basic Film Session SOP Class - N-DELETE
Table N.7-54 lists the Status Codes that the SCU of the Basic Film Session SOP Class supports for the N-DELETE message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-54. Status Codes for N-DELETE of the Basic Film Session SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.1.4 SCU of the Basic Film Session SOP Class - N-ACTION
Table N.7-55 lists the Status Codes that the SCU of the Basic Film Session SOP Class supports for the N-ACTION message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-55. Status Codes for N-Action of the Basic Film Session SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Film belonging to the film session are accepted for printing; if supported, the Print Job SOP Instance is created
|
0000
|
|
|
Warning
|
Film session printing (collation) is not supported
|
B601
|
|
|
Film Session SOP Instance hierarchy does not contain Image Box SOP Instances (empty page)
|
B602
|
|
|
Image size is larger than image box size, the image has been demagnified.
|
B604
|
|
|
Image size is larger than the Image Box size. The Image has been cropped to fit.
|
B609
|
|
|
Image size or Combined Print Image size is larger than the Image Box size. Image or Combined Print Image has been decimated to fit.
|
B60A
|
|
|
Failure
|
Processing failure
|
0110
|
|
|
No such SOP Instance
|
0112
|
|
|
No Such Argument
|
0114
|
|
|
Invalid argument Value
|
0115
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
No Such Action
|
0123
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
Failed: Film Session SOP Instance hierarchy does not contain Film Box SOP Instances
|
C600
|
|
|
Failed: Unable to create Print Job SOP Instance; print queue is full
|
C601
|
|
|
Failed: Image size is larger than image box size
|
C603
|
|
|
Failed: Combined Print Image size is larger than the Image Box size
|
C613
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.2 SCU of the Basic Film Box Session SOP Class
N.7.3.2.8.2.1 SCU of the Basic Film Box Session SOP Class - N-CREATE
Table N.7-52 lists the Status Codes that the SCU of the Basic Film Box SOP Class supports for the N-CREATE message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-56. Status Codes for N-CREATE of the Basic Film Box SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Requested Min Density or Max Density outside of printer's operating range
|
B605
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
There is an existing Film Box that has not been printed and N-ACTION at the Film Session level is not supported. A new Film Box will not be created when a previous Film Box has not been printed
|
C616
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.2.2 SCU of the Basic Film Box Session SOP Class - N-SET
Table N.7-57 lists the Status Codes that the SCU of the Basic Film Box SOP Class supports for the N-SET message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-57. Status Codes for N-SET of the Basic Film Box SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Requested Min Density or Max Density outside of printer's operating range
|
B605
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
There is an existing Film Box that has not been printed and N-ACTION at the Film Session level is not supported. A new Film Box will not be created when a previous Film Box has not been printed
|
C616
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.2.3 SCU of the Basic Film Box Session SOP Class - N-DELETE
Table N.7-58 lists the Status Codes that the SCU of the Basic Film Box SOP Class supports for the N-DELETE message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-58. Status Codes for N-DELETE of the Basic Film Box SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.2.4 SCU of the Basic Film Box Session SOP Class - N-ACTION
Table N.7-59 lists the Status Codes that the SCU of the Basic Film Box SOP Class supports for the N-ACTION message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-59. Status Codes for N-ACTION of the Basic Film Box SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Film Box SOP Instance hierarchy does not contain Image Box SOP Instances (empty page)
|
B603
|
|
|
Image size is larger than Image Box size. The image has been demagnified.
|
B604
|
|
|
Image size is larger than Image Box size. The image has been cropped to fit.
|
B609
|
|
|
Image size or Combined Print Image Size is larger than Image Box size. The image or combined Print Image has been decimated to fit.
|
B60A
|
|
|
Failure
|
Processing failure
|
0110
|
|
|
No such SOP Instance
|
0112
|
|
|
No Such Argument
|
0114
|
|
|
Invalid argument Value
|
0115
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
No Such Action
|
0123
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
Unable to create Print Job SOP Instance; print queue is full.
|
C602
|
|
|
Image size is larger than Image Box size.
|
C603
|
|
|
Combined Print Image Size is larger than Image Box size.
|
C613
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.3 SCU of the Basic Grayscale Image Box SOP Class - N-SET
Table N.7-60 lists the Status Codes that the SCU of the Basic Grayscale Image Box SOP Class supports for the N-SET message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-60. Status Codes for N-SET of the Grayscale Image Box SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Image size is larger than Image Box size. The image has been demagnified.
|
B604
|
|
|
Requested Min Density or Max Density outside of printer's operating range.
|
B605
|
|
|
Image size is larger than Image Box size. The image has been cropped to fit.
|
B609
|
|
|
Image size or Combined Print Image Size is larger than Image Box size. The image or combined Print Image has been decimated to fit.
|
B60A
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
Image size is larger than Image Box size.
|
C603
|
|
|
Insufficient memory in printer to store the image.
|
C605
|
|
|
Combined Print Image Size is larger than Image Box size.
|
C613
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.4 SCU of the Basic Color Image Box SOP Class - N-SET
Table N.7-61 lists the Status Codes that the SCU of the Basic Color Image Box SOP Class supports for the N-SET message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-61. Status Codes for N-SET of the Color Image Box SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Image size is larger than Image Box size. The image has been demagnified.
|
B604
|
|
|
Image size is larger than Image Box size. The image has been cropped to fit.
|
B609
|
|
|
Image size or Combined Print Image Size is larger than Image Box size. The image or combined Print Image has been decimated to fit.
|
B60A
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
Image size is larger than Image Box size.
|
C603
|
|
|
Insufficient memory in printer to store the image.
|
C605
|
|
|
Combined Print Image Size is larger than Image Box size.
|
C613
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.5 SCU of the Printer SOP Class
N.7.3.2.8.5.1 SCU of the Printer SOP Class - N-EVENT-REPORT
Table N.7-62 lists the Status Codes that the SCU of Printer SOP Class supports for the N-EVENT-REPORT message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-62. Status Codes for N-EVENT-REPORT of the Printer SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
No Such SOP Instance
|
0112
|
|
|
No Such Event Type
|
0113
|
|
|
No Such Argument
|
0114
|
|
|
Invalid Argument Value
|
0115
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.5.2 SCU of the Printer SOP Class - N-GET
Table N.7-63 lists the Status Codes that the SCU of the Printer SOP Class supports for the N-GET message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-63. Status Codes for N-GET of the Printer SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
No Such SOP Instance
|
0112
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.6 SCU of the Basic Annotation Box SOP Class - N-SET
Table N.7-64 lists the Status Codes that the SCU of the Basic Annotation Box SOP Class supports for the N-SET message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-64. Status Codes for N-SET of the Basic Annotation Box SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.7 SCU of the Print Job SOP Class
N.7.3.2.8.7.1 SCU of the Print Job SOP Class - N-EVENT-REPORT
Table N.7-65 lists the Status Codes that the SCU of the Print Job SOP Class supports for the N-EVENT-REPORT message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. If any other Status Code is supported add it to the table.] In the "other Status Codes" row document the behavior of the application in case it encounters and unknown Status Code.]
Table N.7-65. Status Codes N-EVENT-REPORT of the Print Job SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
No Such SOP Instance
|
0112
|
|
|
No Such Event Type
|
0113
|
|
|
No Such Argument
|
0114
|
|
|
Invalid Argument Value
|
0115
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.7.2 SCU of the Print Job SOP Class - N-GET
Table N.7-66 lists the Status Codes that the SCU of Print Job SOP Class supports for the N-GET message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-66. Status Codes for N-GET of the Print Job SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
No Such SOP Instance
|
0112
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.8 SCU of the Presentation LUT SOP Class
N.7.3.2.8.8.1 SCU of the Presentation LUT SOP Class - N-CREATE
Table N.7-67 lists the Status Codes that the SCU of the Presentation LUT SOP Class supports for the N-CREATE message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-67. Status Codes N-CREATE of the Presentation LUT SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Requested Min Density or Max Density outside of printer's operating range
|
B605
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.8.2 SCU of the Presentation LUT SOP Class - N-DELETE
Table N.7-68 lists the Status Codes that the SCU of the Presentation LUT SOP Class supports for the N-DELETE message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-68. Status Codes for N-DELETE of the Presentation LUT SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.9 SCU of the Printer Configuration Retrieval SOP Class - N-GET
Table N.7-69 lists the Status Codes that the SCU of the Printer Configuration SOP Class supports for the N-GET message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-69. Status Codes N-GET of the Printer Configuration Retrieval SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
No Such SOP Instance
|
0112
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.8.10 SCP of the Basic Film Session SOP Class
N.7.3.2.8.10.1 SCP of the Basic Film Session SOP Class - N-CREATE
Table N.7-70 lists the Status Codes that the SCP of the Basic Film Session SOP Class supports for the N-CREATE message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-70. Status Codes for N-CREATE of the Basic Film Session SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Memory allocation not supported
|
B600
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Attribute List Error
|
0107
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.10.2 SCP of the Basic Film Session SOP Class - N-SET
Table N.7-71 lists the Status Codes that the SCP of the Basic Film Session SOP Class supports for the N-SET message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-71. Status Codes for N-SET of the Basic Film Session SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute Value Out of Range
|
0116
|
|
|
Attribute List Error
|
0107
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.10.3 SCP of the Basic Film Session SOP Class - N-DELETE
Table N.7-72 lists the Status Codes that the SCP of the Basic Film Session SOP Class supports for the N-DELETE message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-72. Status Codes for N-DELETE of the Basic Film Session SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.10.4 SCP of the Basic Film Session SOP Class - N-ACTION
Table N.7-73 lists the Status Codes that the SCP of the Basic Film Session SOP Class supports for the N-ACTION message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-73. Status Codes for N-ACTION of the Basic Film Session SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Film belonging to the film session are accepted for printing; if supported, the Print Job SOP Instance is created
|
0000
|
|
|
Warning
|
Film session printing (collation) is not supported
|
B601
|
|
|
Film Session SOP Instance hierarchy does not contain Image Box SOP Instances (empty page)
|
B602
|
|
|
Image size is larger than image box size, the image has been demagnified.
|
B604
|
|
|
Image size is larger than the Image Box size. The Image has been cropped to fit.
|
B609
|
|
|
Image size or Combined Print Image size is larger than the Image Box size. Image or Combined Print Image has been decimated to fit.
|
B60A
|
|
|
Failure
|
Failed: Film Session SOP Instance hierarchy does not contain Film Box SOP Instances
|
C600
|
|
|
Failed: Unable to create Print Job SOP Instance; print queue is full
|
C601
|
|
|
Failed: Image size is larger than image box size
|
C603
|
|
|
Failed: Combined Print Image size is larger than the Image Box size
|
C613
|
|
N.7.3.2.8.11 SCP of the Basic Film Box SOP Class
N.7.3.2.8.11.1 SCP of the Basic Film Box SOP Class - N-CREATE
Table N.7-74 lists the Status Codes that the SCP of the Basic Film Box SOP Class supports for the N-CREATE message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-74. Status Codes for N-CREATE of the Basic Film Box SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Requested Min Density or Max Density outside of printer's operating range
|
B605
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
There is an existing Film Box that has not been printed and N-ACTION at the Film Session level is not supported. A new Film Box will not be created when a previous Film Box has not been printed
|
C616
|
|
N.7.3.2.8.11.2 SCP of the Basic Film Box SOP Class - N-SET
Table N.7-75 lists the Status Codes that the SCP of the Basic Film Box SOP Class supports for the N-SET message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-75. Status Codes for N-SET of the Basic Film Box SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Requested Min Density or Max Density outside of printer's operating range
|
B605
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
There is an existing Film Box that has not been printed and N-ACTION at the Film Session level is not supported. A new Film Box will not be created when a previous Film Box has not been printed
|
C616
|
|
N.7.3.2.8.11.3 SCP of the Basic Film Box SOP Class - N-DELETE
Table N.7-76 lists the Status Codes that the SCP of the Basic Film Box SOP Class supports for the N-DELETE message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-76. Status Codes for N-DELETE of the Basic Film Box SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.11.4 SCP of the Basic Film Box SOP Class - N-ACTION
Table N.7-77 lists the Status Codes that the SCP of the Basic Film Box SOP Class supports for the N-ACTION message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-77. Status Codes for N-ACTION of the Basic Film Box SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Film Box SOP Instance hierarchy does not contain Image Box SOP Instances (empty page)
|
B603
|
|
|
Image size is larger than Image Box size. The image has been demagnified.
|
B604
|
|
|
Image size is larger than Image Box size. The image has been cropped to fit.
|
B609
|
|
|
Image size or Combined Print Image Size is larger than Image Box size. The image or combined Print Image has been decimated to fit.
|
B60A
|
|
|
Failure
|
Processing failure
|
0110
|
|
|
No such SOP Instance
|
0112
|
|
|
No Such Argument
|
0114
|
|
|
Invalid argument Value
|
0115
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
No Such Action
|
0123
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
Unable to create Print Job SOP Instance; print queue is full.
|
C602
|
|
|
Image size is larger than Image Box size.
|
C603
|
|
|
Combined Print Image Size is larger than Image Box size.
|
C613
|
|
N.7.3.2.8.12 SCP of the Basic Grayscale Image Box SOP Class - N-SET
Table N.7-78 lists the Status Codes that the SCP of the Basic Grayscale Image Box SOP Class supports for the N-SET message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-78. Status Codes for N-SET of the Basic Grayscale Image Box SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Image size is larger than Image Box size. The image has been demagnified.
|
B604
|
|
|
Requested Min Density or Max Density outside of printer's operating range.
|
B605
|
|
|
Image size is larger than Image Box size. The image has been cropped to fit.
|
B609
|
|
|
Image size or Combined Print Image Size is larger than Image Box size. The image or combined Print Image has been decimated to fit.
|
B60A
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
Image size is larger than Image Box size.
|
C603
|
|
|
Insufficient memory in printer to store the image.
|
C605
|
|
|
Combined Print Image Size is larger than Image Box size.
|
C613
|
|
N.7.3.2.8.13 SCP of the Basic Color Image Box SOP Class - N-SET
Table N.7-79 lists the Status Codes that the SCP of the Basic Color Image Box SOP Class supports for the N-SET message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-79. Status Codes for N-SET of the Basic Color Image Box SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Image size is larger than Image Box size. The image has been demagnified.
|
B604
|
|
|
Requested Min Density or Max Density outside of printer's operating range.
|
B605
|
|
|
Image size is larger than Image Box size. The image has been cropped to fit.
|
B609
|
|
|
Image size or Combined Print Image Size is larger than Image Box size. The image or combined Print Image has been decimated to fit.
|
B60A
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
Image size is larger than Image Box size.
|
C603
|
|
|
Insufficient memory in printer to store the image.
|
C605
|
|
|
Combined Print Image Size is larger than Image Box size.
|
C613
|
|
N.7.3.2.8.14 SCP of the Printer SOP Class
N.7.3.2.8.14.1 SCP of the Printer SOP Class - N-EVENT-REPORT
Table N.7-80 lists the Status Codes that the SCP of the Printer SOP Class supports for the N-EVENT-REPORT message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-80. Status Codes for N-EVENT-REPORT of the Printer SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
No Such SOP Instance
|
0112
|
|
|
No Such Event Type
|
0113
|
|
|
No Such Argument
|
0114
|
|
|
Invalid Argument Value
|
0115
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.14.2 SCP of the Printer SOP Class - N-GET
Table N.7-81 lists the Status Codes that the SCP of the Printer SOP Class supports for the N-GET message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-81. Status Codes for N-GET of the Printer SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
No Such SOP Instance
|
0112
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.15 SCP the Basic Annotation Box SOP Class - N-SET
Table N.7-82 lists the Status Codes that the SCP of the Basic Annotation Box SOP Class supports for the N-SET message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-82. Status Codes for N-SET of the Basic Annotation Box SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.16 SCP of the Print Job SOP Class
N.7.3.2.8.16.1 SCP of the Print Job SOP Class - N-EVENT-REPORT
Table N.7-83 lists the Status Codes that the SCP of the Print Job SOP Class supports for the N-EVENT-REPORT message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-83. Status Codes for N-EVENT-REPORT of the Print Job SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
No Such SOP Instance
|
0112
|
|
|
No Such Event Type
|
0113
|
|
|
No Such Argument
|
0114
|
|
|
Invalid Argument Value
|
0115
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.16.2 SCP of the Print Job SOP Class - N-GET
Table N.7-84 lists the Status Codes that the SCP of the Print Job SOP Class supports for the N-GET message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-84. Status Codes for N-GET of the Print Job SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
No Such SOP Instance
|
0112
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.17 SCP of the Presentation LUT SOP Class
N.7.3.2.8.17.1 SCP of the Presentation LUT SOP Class - N-CREATE
Table N.7-85 lists the Status Codes that the SCP of the Presentation LUT SOP Class supports for the N-CREATE message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-85. Status Codes for N-CREATE of the Presentation LUT SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Requested Min Density or Max Density outside of printer's operating range
|
B605
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.17.2 SCP of the Presentation LUT SOP Class - N-DELETE
Table N.7-86 lists the Status Codes that the SCP of the Presentation LUT SOP Class supports for the N-DELETE message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-86. Status Codes for N-DELETE of the Presentation LUT SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
N.7.3.2.8.18 SCP of the Printer Configuration Retrieval SOP Class - N-GET
Table N.7-87 lists the Status Codes that the SCP of the Printer Configuration SOP Class supports for the N-GET message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-87. Status Codes for N-GET of the Printer Configuration Retrieval SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute List Error
|
0107
|
|
|
Failure
|
Processing Failure
|
0110
|
|
|
No Such SOP Instance
|
0112
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|