N.7.3.2.7 Query/Retrieve Service
N.7.3.2.7.1 SCU of the Query/Retrieve FIND SOP Classes - C-FIND
Table N.7-48 lists the Status Codes that the SCU of any of the Query/Retrieve FIND SOP Class supports for the C-FIND message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-48. Status Codes C-FIND for Query/Retrieve FIND SOP Classes - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Matching is complete - No final identifier is supplied
|
0000
|
|
|
Failure
|
Refused: Out of Resources
|
A700
|
|
|
Error: Data Set does not match SOP Class
|
A900
|
|
|
Error: Unable to process
|
C000-CFFF
|
|
|
SOP Class Not Supported
|
0122
|
|
|
Cancel
|
Matching terminated due to cancel
|
FE00
|
|
|
Pending
|
Matches are continuing - Current Match is supplied and any Optional Keys were supported in the same manner as Required Keys.
|
FF00
|
|
|
Matches are continuing - Warning that one or more Optional Keys were not supported for existence for this Identifier
|
FF01
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.7.2 SCU of the Query/Retrieve MOVE SOP Classes - C-MOVE
Table N.7-49 lists the Status Codes that the SCU of any of the Query/Retrieve MOVE SOP Class supports for the C-MOVE message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-49. Status Codes C-MOVE for Query/Retrieve MOVE SOP Classes - SCU
|
Service Status
|
Further Meaning
|
Status Codes
|
Related Fields
|
Behavior
|
|
Success
|
Sub-operations Complete - No Failures
|
0000
|
(0000,1020)
(0000,1021)
(0000,1022)
(0000,1023)
|
|
|
Warning
|
Sub-operations Complete - One or more Failures
|
B000
|
(0000,1020)
(0000,1022)
(0000,1023)
|
|
|
Failed
|
Out of Resources - Unable to calculate number of matches
|
A701
|
(0000,0902)
|
|
|
Out of Resources - Unable to perform sub-operations
|
A702
|
(0000,1020)
(0000,1021)
(0000,1022)
(0000,1023)
|
|
|
Move Destination unknown
|
A801
|
(0000,0902)
|
|
|
Data Set does not match SOP Class
|
A900
|
(0000,0901)
(0000,0902)
|
|
|
Unable to process
|
Cxxx
|
(0000,0901)
(0000,0902)
|
|
|
Cancel
|
Sub-operations terminated due to Cancel Indication
|
FE00
|
(0000,1020)
(0000,1021)
(0000,1022)
(0000,1023)
|
|
|
Pending
|
Sub-operations are continuing
|
FF00
|
(0000,1020)
(0000,1021)
(0000,1022)
(0000,1023)
|
|
|
-
|
Other Status Codes
|
anything else
|
-
|
|
N.7.3.2.7.3 SCP of the Query/Retrieve FIND SOP Classes - C-FIND
Table N.7-50 lists the Status Codes that the SCP of any of the Query/Retrieve FIND SOP Classes supports for the C-FIND message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-50. Status Codes C-FIND for Query/Retrieve FIND SOP Classes - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Matching is complete - No final identifier is supplied
|
0000
|
|
|
Failure
|
Refused: Out of Resources
|
A700
|
|
|
Error: Data Set does not match SOP Class
|
A900
|
|
|
Error: Unable to process
|
C000
|
|
|
SOP Class Not Supported
|
0122
|
|
|
Cancel
|
Matching terminated due to cancel
|
FE00
|
|
|
Pending
|
Matches are continuing - Current Match is supplied and any Optional Keys were supported in the same manner as Required Keys.
|
FF00
|
|
|
Matches are continuing - Warning that one or more Optional Keys were not supported for existence for this Identifier
|
FF01
|
|
N.7.3.2.7.4 SCP of the Query/Retrieve MOVE SOP Classes - C-MOVE
Table N.7-51 lists the Status Codes that the SCP of any of the Query/Retrieve MOVE SOP Classes supports for the C-MOVE message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
[Describe the action on the storage sub-operation due to above mentioned conditions. Mention what happens to the store sub-operation when the specific condition occurs.]
Table N.7-51. Status Codes C-MOVE for Query/Retrieve MOVE SOP Classes - SCP
|
Service Status
|
Further Meaning
|
Status Codes
|
Related Fields sent in the response
|
Condition
|
Action on the Store due the condition.
|
|
Success
|
Sub-operations Complete - No Failures
|
0000
|
(0000,1020)
(0000,1021)
(0000,1022)
(0000,1023)
|
|
|
|
Warning
|
Sub-operations Complete - One or more Failures
|
B000
|
(0000,1020)
(0000,1022)
(0000,1023)
|
|
|
|
Failed
|
Out of Resources - Unable to calculate number of matches
|
A701
|
(0000,0902)
|
|
|
|
Out of Resources - Unable to perform sub-operations
|
A702
|
(0000,1020)
(0000,1021)
(0000,1022)
(0000,1023)
|
|
|
|
Move Destination unknown
|
A801
|
(0000,0902)
|
|
|
|
Data Set does not match SOP Class
|
A900
|
(0000,0901)
(0000,0902)
|
|
|
|
Unable to process
|
Cxxx
|
(0000,0901)
(0000,0902)
|
|
|
|
Cancel
|
Sub-operations terminated due to Cancel Indication
|
FE00
|
(0000,1020)
(0000,1021)
(0000,1022)
(0000,1023)
|
|
|
|
Pending
|
Sub-operations are continuing
|
FF00
|
(0000,1020)
(0000,1021)
(0000,1022)
(0000,1023)
|
|
|