N.7.3.2.2.1 SCU of the Modality Performed Procedure Step SOP Class - N-CREATE
Table N.7-12 lists the Status Codes that the SCU of the Modality Performed Procedure Step SOP Class supports for the N-CREATE message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.]
[In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-12. Status Codes for N-CREATE of the Modality Performed Procedure Step SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute Value Out of Range
|
0116
|
|
|
Attribute List Error
|
0107
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure
|
0110
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.2.2 SCU of the Modality Performed Procedure Step SOP Class - N-SET
Table N.7-13 lists the Status Codes that the SCU of the Modality Performed Procedure Step SOP Class supports for the N-SET message and defines the application behavior when encountering the listed Status Codes.
[Describe the behavior of the application when it receives any of the Status Codes listed in the table below, e.g., displaying and logging the error code or retrying the request. For each additional Status Code supported add a row to the table.
In the "Other Status Codes" row document the behavior of the application in case it encounters an unknown Status Code.]
Table N.7-13. Status Codes for N-SET of the Modality Performed Procedure Step SOP Class - SCU
|
Service Status
|
Further Meaning
|
Status Code
|
Behavior
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute Value Out of Range
|
0116
|
|
|
Attribute List Error
|
0107
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure - Performed Procedure Step Object may no longer be updated
|
0110
|
|
|
Processing Failure
|
0110
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|
|
-
|
Other Status Codes
|
anything else
|
|
N.7.3.2.2.3 SCP of the Modality Performed Procedure Step SOP Class - N-CREATE
Table N.7-14 lists the Status Codes that the SCP of the Modality Performed Procedure Step SOP Class supports for the N-CREATE message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-14. Status Codes for N-CREATE of the Modality Performed Procedure Step SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute Value Out of Range
|
0116
|
|
|
Attribute List Error
|
0107
|
|
|
Failure
|
Duplicate Invocation
|
0210
|
|
|
Duplicate SOP Instance
|
0111
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Invalid SOP Instance
|
0117
|
|
|
Missing Attribute
|
0120
|
|
|
Missing Attribute Value
|
0121
|
|
|
Mistyped Argument
|
0212
|
|
|
No Such Attribute
|
0105
|
|
|
No Such SOP Class
|
0118
|
|
|
Processing Failure
|
0110
|
|
|
Resource Limitation
|
0213
|
|
|
Unrecognized Operation
|
0211
|
|
|
Refused: Not Authorized
|
0124
|
|
N.7.3.2.2.4 SCP of the Modality Performed Procedure Step SOP Class - N-SET
Table N.7-15 lists the Status Codes that the SCP of the Modality Performed Procedure Step SOP Class supports for the N-SET message and defines conditions in which the listed Status Codes are sent.
[Describe the condition which causes the application to send the specific Status Codes. For each other Status Code used add a row to the table.]
Table N.7-15. Status Codes for N-SET of the Modality Performed Procedure Step SOP Class - SCP
|
Service Status
|
Further Meaning
|
Status Code
|
Condition
|
|
Success
|
Success
|
0000
|
|
|
Warning
|
Attribute Value Out of Range
|
0116
|
|
|
Attribute List Error
|
0107
|
|
|
Failure
|
No Such Attribute
|
0105
|
|
|
Invalid Attribute Value
|
0106
|
|
|
Processing Failure - Performed Procedure Step Object may no longer be updated
|
0110
|
|
|
Processing Failure
|
0110
|
|
|
Attribute Value Out of Range
|
0116
|
|
|
Invalid SOP Instance
|
0117
|
|
|
No Such SOP Class
|
0118
|
|
|
Class-Instance Conflict
|
0119
|
|
|
Missing Attribute Value
|
0121
|
|
|
Refused: Not Authorized
|
0124
|
|
|
Duplicate Invocation
|
0210
|
|
|
Unrecognized Operation
|
0211
|
|
|
Mistyped Argument
|
0212
|
|
|
Resource Limitation
|
0213
|
|