DICOM PS3.20 2023e - Imaging Reports using HL7 Clinical Document Architecture

9.8.7 DICOM Object Catalog

Template ID

2.16.840.1.113883.​10.20.6.1.1

Name

DICOM Object Catalog Section

Effective Date

2012-07

Version Label

CCDA-1.1

Status

Active

Description

DICOM Object Catalog lists all referenced objects and their parent Series and Studies, plus other DICOM attributes required for retrieving the objects. The DICOM Object Catalog section is not intended for viewing and may contain empty section text.

Classification

CDA Section Level

Relationships

Included in 9.3 Imaging Procedure Description

Context

parent node

Open/Closed

Open

Revision History

From Consolidated CDA r1.1

Business Name

Nest Level

Element/​Attribute

Card

Elem/Attr Conf

Data Type

Value Conf

Value

Subsidiary Template

DICOMCatalog

section

1..1

SHALL

>

template​Id

1..1

SHALL

II

>@

@root

1..1

SHALL

UID

SHALL

2.16.840.1.113883.​10.20.6.1.1

>

id

1..*

SHALL

II

>

code

1..1

SHALL

CD

SHALL

(121181, DCM, "Dicom Object Catalog")

Title

>

title

1..1

SHALL

ST

Text

>

text

1..1

SHALL

ED

9.1.1 Section Text 1.2.840.10008.9.19

>

entry

0..*

SHOULD

Study[*]

>>

act

1..1

SHALL

10.6 Study Act 2.16.840.1.113883.​10.20.6.2.6

Example 9.8.7-1. DICOM object catalog section example

<section classCode="DOCSECT" moodCode="EVN">
	<templateId root="2.16.840.1.113883.10.20.6.1.1"/>
	<id root="1.2.840.10213.2.62.70447834679.11429737"/>
	<code code="121181"
		codeSystem="1.2.840.10008.2.16.4"
		codeSystemName="DCM"
		displayName="DICOM Object Catalog"/>
	<entry>
        <!-- **** Study Act **** -->
        <act classCode="ACT" moodCode="EVN">
			<templateId root="2.16.840.1.113883.10.20.6.2.6"/>
			<id root="1.2.840.113619.2.62.994044785528.114289542805"/>
			<code code="113014" codeSystem="1.2.840.10008.2.16.4"
				codeSystemName="DCM" displayName="Study"/>
			<!-- **** Series Act ****-->
			<entryRelationship typeCode="COMP">
				<act classCode="ACT" moodCode="EVN">
					<id root="1.2.840.113619.2.62.994044785528.20060823223142485051"/>
					<code code="113015" codeSystem="1.2.840.10008.2.16.4"
						codeSystemName="DCM" displayName="Series">
						...
					</code>
					<!-- **** SOP Instance UID *** -->
					<!-- 2 References -->
					<entryRelationship typeCode="COMP">
						<observation classCode="DGIMG" moodCode="EVN">
							<templateId root="2.16.840.1.113883.10.20.6.2.8"/>
							...
						</observation>
					</entryRelationship>
					<entryRelationship typeCode="COMP">
						<observation classCode="DGIMG" moodCode="EVN">
							<templateId root="2.16.840.1.113883.10.20.6.2.8"/>
							...
						</observation>
					</entryRelationship>
				</act>
			</entryRelationship>
        </act>
	</entry>

DICOM PS3.20 2023e - Imaging Reports using HL7 Clinical Document Architecture