DICOM PS3.17 2023e - Explanatory Information

T.3.2 Centerline Wall Motion Region

Example of Centerline Wall Motion Template Usage

Figure T.3-2. Example of Centerline Wall Motion Template Usage


Node

Code Meaning of Concept Name

Code Meaning or Example Value

TID

X.X

Findings

X.X.1

Procedure Reported

Centerline Wall Motion Analysis

TID 3208

X.X.2

Contour Realignment

Center of Gravity

TID 3208

X.X.3

Normalized Chord Length

5.0 %

TID 300

X.X.4

Normalized Chord Length

5.1 %

TID 300

X.X.5

Normalized Chord Length

5.3 %

TID 300

…

…

…

…

X.X.102

Normalized Chord Length

4.5 %

TID 300

X.X.103

Threshold Value

2

TID 3208

X.X.104

Abnormal Region

TID 3208

X.X.104.1

Cardiac Wall Motion

Hypokinetic

TID 3208

X.X.104.2

Circumferential Extend

LAD Region

TID 3208

X.X.104.3

First Chord of Abnormal Region

66

TID 3208

X.X.104.4

Last Chord of Abnormal Region

76

TID 3208

X.X.104.5

Cardiac Wall Motion

Hypokinetic

TID 3208

X.X.104.6

Circumferential Extend

RCA Region

TID 3208

X.X.104.7

First Chord of Abnormal Region

66

TID 3208

X.X.104.8

Last Chord of Abnormal Region

76

TID 3208

X.X.104.9

Cardiac Wall Motion

Hyperkinetic

TID 3208

X.X.104.10

Circumferential Extend

LAD Region

TID 3208

X.X.104.11

First Chord of Abnormal Region

14

TID 3208

X.X.104.12

Last Chord of Abnormal Region

48

TID 3208

X.X.104.13

Cardiac Wall Motion

Hyperkinetic

TID 3208

X.X.104.14

Circumferential Extend

RCA Region

TID 3208

X.X.104.15

First Chord of Abnormal Region

25

TID 3208

X.X.104.16

Last Chord of Abnormal Region

48

TID 3208

X.X.104.17

Cardiac Wall Motion

Akinetic

TID 3208

X.X.104.18

Circumferential Extend

LAD Region

TID 3208

X.X.104.19

First Chord of Abnormal Region

69

TID 3208

X.X.104.20

Last Chord of Abnormal Region

71

TID 3208

X.X.104.21

Cardiac Wall Motion

Akinetic

TID 3208

X.X.104.22

Circumferential Extend

RCA Region

TID 3208

X.X.104.23

First Chord of Abnormal Region

69

TID 3208

X.X.104.24

Last Chord of Abnormal Region

71

TID 3208

X.X.105

Regional Abnormal Wall Motion

TID 3208

X.X.105.1

Finding Site

Single LAD Region in RAO Projection

TID 3208

X.X.105.2

Territory Region Severity

6.6

TID 300

X.X.105.2.1

Cardiac Wall Motion

Hypokinetic

TID 300

X.X.105.3

Opposite Region Severity

3.1

TID 300

X.X.105.3.1

Cardiac Wall Motion

Hyperkinetic

TID 300

X.X.105.4

Finding Site

Single RCA Region in RAO Projection

TID 3208

X.X.105.5

Territory Region Severity

2.6

TID 300

X.X.105.5.1

Cardiac Wall Motion

Hyperkinetic

TID 300

X.X.105.6

Opposite Region Severity

7.6

TID 300

X.X.105.6.1

Cardiac Wall Motion

Hypokinetic

TID 300

X.X.105.7

Finding Site

Multiple LAD Region in RAO Projection

TID 3208

X.X.105.8

Territory Region Severity

7.1

TID 300

X.X.105.8.1

Cardiac Wall Motion

Hyperkinetic

TID 300

X.X.105.9

Opposite Region Severity

2.9

TID 300

X.X.105.9.1

Cardiac Wall Motion

Hyperkinetic

TID 300

X.X.105.10

Finding Site

Multiple RCA in Region RAO Projection

TID 3208

X.X.105.11

Territory Region Severity

2.9

TID 300

X.X.105.11.1

Cardiac Wall Motion

Hypokinetic

TID 300

X.X.105.12

Opposite Region Severity

7.1

TID 300

X.X.105.12.1

Cardiac Wall Motion

Hyperkinetic

TID 300

X.X 106

…

…

TID 3208

DICOM PS3.17 2023e - Explanatory Information