C.38.2.4 Access End Points Macro

Table C.38.2-4 specifies the Attributes of the Access End Points Macro, which describe the available network access protocol end point(s), i.e., network addresses, for referenced SOP Instances.

Table C.38.2-4. Access End Points Macro Attributes

Attribute Name

Tag

Type

Attribute Description

Retrieve AE Title

(0008,0054)

3

AE Title end point from which SOP Instances may be retrieved using a C-MOVE or C-GET based SOP Class (see PS3.4). This AE Title is used together with one or more of Referenced SOP Instance UID (0008,1155), Study Instance UID (0020,000D), and/or and Series Instance UID (0020,000E) values.

Retrieve URL

(0008,1190)

3

Base URI end point of the origin server from which SOP Instances may be retrieved using a DICOM web-based service (see PS3.18). This base URI is used together with one or more of Referenced SOP Instance UID (0008,1155), Study Instance UID (0020,000D), and/or and Series Instance UID (0020,000E) values.

Stored Instance Base URI

(0008,0407)

3

Base URI end point from which SOP Instances may be retrieved using a non-DICOM protocol (see Annex P). This base URI is used together with a relative path File Access URI (0008,0409) or a Folder Access URI (0008,0408) value.